Nicolet

Post on 07-Feb-2017

215 views 0 download

transcript

Program

11:50 (283) Laser Mass Spectra of Aro­matic Thioamides—S.K. Viswana-dham, D.M. Hercules, U of Pitts­burgh

12:10 (284) Photofragment Spectros­copy (PFS): Studies of Dissociation Dynamics of Highly Activated Ionic Systems—R.E. Krai l ler , D.H. Rus­sell, Texas A&M U

Multidimensional Gas Chromatography and Related Retention Determinations

Room B, Convention Center

9:00 (285) Design Requirements for Multidimensional Gas Chromatog­raphy—J. Widomski, T. Lyons, B. Welton, Perkin-Elmer

9:20 (286) State-of-the-Art Gas Chro­matography: Instrumental Design Features—W. Jennings, U of Cali­fornia, Davis

9:40 (287) Unique Applications of In­dependently Heated GC Systems— S.M. Sonchik, J.Q. Walker, IBM In­struments Inc.

10:00 (288) Multidimensional High-Resolution Gas Chromatography with a Double Oven—Possibilities and Technical Implementation—U.K. Goekeler, ES Industries, F. Muel­ler

10:20 (289) Correlations between Monte Carlo-Van Der Waals' Volume and Retention Index—D. Ciubotariu, The Polytechic "T. Vuia," S. Holban, L. Cotarca, E. Tsiliris

10:40 Recess 10:50 (290) Development of a Retention

Index Library Using High-Perfor-mance Capillary Columns—J.F. Sprouse, A. Varano, A. Rahman, Sadtler Research Laboratories

11:10 (291) Dual Capillary Column Analysis of Complex Oxygenated Mixtures—J.M. Levy, J.A. Yancey, The Standard Oil Co.

New Instrumentation III

Room 311, Convention Center

9:00 (294) Resonance Ionization Mass Spectrometry—J.P. Young, D. L. Donohue, D.H. Smith, Oak Ridge National Laboratory

9:20 (295) Performance and Application of New Techniques in BEQQ Hybrid Mass Spectrometry—A.E. Schoen, Finnigan MAT, P. Dobberstein, J.D. Ciupek, J.R. O'Lear, J.W. Amy, R.G. Cooks

9:40 (296) Resolution Study by Com­puter Simulation of a Two-Stage Ve­locity Compaction TOF Mass Spec­trometer—M.L. Muga, TOFTEC

10:00 (297) A New, Integrated Gas Chromatographic/Mass Selective De­tection System—S.E. Strong, T. Bruhns, Hewlett-Packard

10:20 (298) Applications of an Inte­grated GC/Mass Selective Detection System—S.E. Strong, T. Bruhns, Hewlett-Packard

10:40 Recess 10:50 (299) Elemental Composition

Determinations of Peptides in the Higher Mass Range under FAB Con­ditions—U. Rapp, R. Pesch, G. Jung, M. Hoehn, Finnigan MAT GmbH

11:10 (300) Analyses in Which GC/ Matrix Isolation/IR Outperforms GC/MS—D.G. Et t inger , G.T. Reedy, S. Bourne, J.C. Demirgian, Argonne National Laboratory

Complete Structure Determination

Now Faster, Easier.

Single-crystal XRD comes of age. Of all available techniques, x-ray crystallography alone is capable of

unambiguously determining complete three-dimensional molecular structures, confirming the connectivity and

stereochemistry of molecules, and providing precise information concerning bond lengths, bond angles, and

molecular dimensions. N ico l e t ' s a d v a n c e d c r y s t a l l o g r a p h y s y s t e m s a r e

d e s i g n e d s o t h a t c h e m i s t s w i t h m i n i m a l c r y s t a l l o g r a p h i c t r a i n i n g c a n r a p i d l y a n d r o u t i n e l y s o l v e m o l e c u l a r s t r u c t u r e s . For example, the structure

of an organic or organometallic molecule having 25 non-hydrogen atoms can typically be solved in less than a

day wi th the Nicolet R3m/E — a typical laboratory n o w solves over 100 structures per year using this system!

N ico l e t ' s s o f t w a r e a n d h a r d w a r e a d v a n c e s h a v e t a k e n t h e t e d i u m o u t of s t r u c t u r e d e t e r m i n a t i o n . Our

complete systems rapidly and simultaneously perform data collection, s tructure determination, display, and plotting of

three-dimensional structures, wi thout the need for an external computer.

Contact Nicolet to get the full structural story.

Nicolet Analytical Division · 5225-1 Verona Road · Madison, WI 53711

(608)273-5004

CIRCLE 217 ON READER SERVICE CARD

ANALYTICAL CHEMISTRY, VOL. 56, NO. 2, FEBRUARY 1984 · 165 A

NIC