+ All Categories
Home > Documents > Ancore Chimice Mecanice Pentru Sarcinimari

Ancore Chimice Mecanice Pentru Sarcinimari

Date post: 13-Apr-2015
Category:
Upload: dan-limburg
View: 102 times
Download: 0 times
Share this document with a friend
Description:
Ancorare
109
8 HVZ Ancore chimice pentru sarcini mari în zonă întinsă Timp de întărire Temperatură în gaură ³ + 20 °C ³ + 10 °C ³ 0 °C ³ - 5 °C Interval de aşteptare între poziţionare şi încărcare 20 min. 30 min. 1 oră 5 ore HVU-TZ Cartuşe pentru ancore chimice Adâncime gaură= lungime cartuş (mm) x nominal burghiu (mm) Adâncime de pozare (mm) Cod comandă Nr. articol 90 12 90 HVU-TZ M10x90 311368 10 110 14 110 HVU-TZ M12x110 311369 10 125 / 145 18 105 / 125 HVU-TZ M16x125 311370 5 195 25 170 HVU-TZ M20x170 335942 4 HAS-TZ Tijă de ancorare 15 124 75 12 HAS-TZ M10x75/15 310018 10 30 139 75 12 HAS-TZ M10x75/30 308383 10 50 159 75 12 HAS-TZ M10x75/50 308384 10 25 158 95 14 HAS-TZ M12x95/25 308385 10 50 183 95 14 HAS-TZ M12x95/50 308386 10 100 233 95 14 HAS-TZ M12x95/100 308387 10 30 181 105 18 HAS-TZ M16x105/30 308388 5 60 211 105 18 HAS-TZ M16x105/60 308389 5 100 251 105 18 HAS-TZ M16x105/100 308390 5 30 201 125 18 HAS-TZ M16x125/30 332519 5 60 231 125 18 HAS-TZ M16x125/60 332520 5 100 271 125 18 HAS-TZ M16x125/100 332521 5 40 269 170 25 HAS-TZ M20x170/40 335943 4 Date tehnice Extras din aprobarea ETA: ETA-03/0032 HVZ/HAS-TZ M10 M12 M16x105 M16x125 M20 Material de ancorare Beton C20/25 1) Solicitare la tracţiune adm. (zonă comprimată) N [kN] 15,6 19,1 25,8 33,6 53,2 1) Solicitare la tracţiune admisă (zonă întinsă) N [kN] 9,5 15,9 18,4 23,9 1) Solicitare la forfecare admisă V [kN] 10,3 15,4 29,1 29,1 50,3 Distanţă necesară faţă de margine Ccr [cm] 11,5 14,5 15,5 18,5 25,5 Distanţă necesară între axe Scr [cm] 22 30 33 39 51 2) Distanţă minimă faţă de margini Cmin [cm] 5 7 8,5 8,5 8 2) Distanţă minimă între axe Smin [cm] 5 6 7 7 8 Diametru gaură do [mm] 12 14 18 18 Adâncime gaură h1 [cm] 9 11 12,5 14,5 Grosime min. element de construcţie hmin [cm] 15 19 21 25 Gaură de trecere [mm] 13 15 19 19 22 Moment de strângere Tinst [Nm] 40 50 90 90 HVU-TZ Cartuş pentru ancora chimică HAS-TZ / HAS-R TZ Tijă de ancorare Deschidere cheie SW [mm] 19 24 24 30 17 38 25 19,5 34 150 1) Sarcinile admisibile sunt valabile pentru fixări individuale la distanţă faţă de margini, cu armătură densă, coeficient parţial de siguranţă al aplicării forţei 1,4 2) Sarcinile admisibile trebuiesc reduse în conformitate cu aprobarea ETA Informaţii suplimentare puteţi găsi în Manualul tehnicii de ancorare Hilti, sau pe Internet la adresa www.hilti.ro. h(min) tfix Tinst. h1 Buc./ ambalaj Execuţie: cu piuliţă şi şaibă de susţinere. Material oţel 8.8, zincat galvanic cu 5 μm Înălţime de fixare Lungime tijă (mm) Adâncime de pozare (mm) Cod comandă Nr. articol Buc./ ambalaj x nominal burghiu (mm) 130 Ancore pentru sarcini mari / Chimice
Transcript
Page 1: Ancore Chimice Mecanice Pentru Sarcinimari

8 HVZ Ancore chimicepentru sarcini mari în zonă întinsă

Timp de întărireTemperatură în gaură ³ + 20 °C ³ + 10 °C ³ 0 °C ³ - 5 °CInterval de aşteptare între poziţionare şi încărcare 20 min. 30 min. 1 oră 5 ore

HVU-TZ Cartuşe pentru ancore chimiceAdâncime gaură=lungime cartuş (mm)

x nominalburghiu (mm)

Adâncimede pozare (mm)

Codcomandă

Nr. articol

90 12 90 HVU-TZ M10x90 311368 10110 14 110 HVU-TZ M12x110 311369 10125 / 145 18 105 / 125 HVU-TZ M16x125 311370 5195 25 170 HVU-TZ M20x170 335942 4

HAS-TZ Tijă de ancorare

15 124 75 12 HAS-TZ M10x75/15 310018 1030 139 75 12 HAS-TZ M10x75/30 308383 1050 159 75 12 HAS-TZ M10x75/50 308384 1025 158 95 14 HAS-TZ M12x95/25 308385 1050 183 95 14 HAS-TZ M12x95/50 308386 10

100 233 95 14 HAS-TZ M12x95/100 308387 1030 181 105 18 HAS-TZ M16x105/30 308388 560 211 105 18 HAS-TZ M16x105/60 308389 5

100 251 105 18 HAS-TZ M16x105/100 308390 530 201 125 18 HAS-TZ M16x125/30 332519 560 231 125 18 HAS-TZ M16x125/60 332520 5

100 271 125 18 HAS-TZ M16x125/100 332521 540 269 170 25 HAS-TZ M20x170/40 335943 4

Date tehniceExtras din aprobarea ETA: ETA-03/0032

HVZ/HAS-TZ M10 M12 M16x105 M16x125 M20

Material de ancorare Beton C20/251) Solicitare la tracţiune adm. (zonă comprimată) N [kN] 15,6 19,1 25,8 33,6 53,21) Solicitare la tracţiune admisă (zonă întinsă) N [kN] 9,5 15,9 18,4 23,91) Solicitare la forfecare admisă V [kN] 10,3 15,4 29,1 29,1 50,3Distanţă necesară faţă de margine Ccr [cm] 11,5 14,5 15,5 18,5 25,5Distanţă necesară între axe Scr [cm] 22 30 33 39 512) Distanţă minimă faţă de margini Cmin [cm] 5 7 8,5 8,5 82) Distanţă minimă între axe Smin [cm] 5 6 7 7 8Diametru gaură do [mm] 12 14 18 18Adâncime gaură h1 [cm] 9 11 12,5 14,5Grosime min. element de construcţie hmin [cm] 15 19 21 25Gaură de trecere [mm] 13 15 19 19 22Moment de strângere Tinst [Nm] 40 50 90 90

HVU-TZ Cartuş pentru ancora chimică

HAS-TZ / HAS-R TZ Tijă de ancorare

Deschidere cheie SW [mm] 19 24 24 3017

38

2519,534

150

1) Sarcinile admisibile sunt valabile pentru fixări individuale la distanţă faţă de margini, cu armătură densă, coeficient parţial de siguranţă al aplicării forţei 1,42) Sarcinile admisibile trebuiesc reduse în conformitate cu aprobarea ETA Informaţii suplimentare puteţi găsi în Manualul tehnicii de ancorare Hilti, sau pe Internet la adresa www.hilti.ro.

h(min) tfix

Tinst.

h1

Buc./ambalaj

Execuţie: cu piuliţă şi şaibă de susţinere. Material oţel 8.8, zincat galvanic cu ≥ 5 μm

Înălţimede fixare

Lungimetijă (mm)

Adâncime depozare (mm)

Codcomandă

Nr. articol Buc./ambalaj

x nominalburghiu (mm)

130

Ancore pentru sarcini mari / Chimice

Page 2: Ancore Chimice Mecanice Pentru Sarcinimari

HAS-R-TZ Tije de ancorare inoxidabile A4

Execuţie: cu piuliţă şi şaibă de susţinere.Material: oţel inoxidabil A4-80, indice material 1.4401 / 1.4571

15 124 75 12 HAS-R-TZ M10x75/10 310019 1030 139 75 12 HAS-R-TZ M10x75/30 308391 1050 159 75 12 HAS-R-TZ M10x75/50 308392 1025 158 95 14 HAS-R-TZ M12x95/25 308393 1050 183 95 14 HAS-R-TZ M12x95/50 308394 10

100 233 95 14 HAS-R-TZ M12x95/100 308395 1030 181 105 18 HAS-R-TZ M16x105/30 308396 560 211 105 18 HAS-R-TZ M16x105/60 308397 5

100 251 105 18 HAS-R-TZ M16x105/100 308398 530 201 125 18 HAS-R-TZ M16x125/30 332522 560 231 125 18 HAS-R-TZ M16x125/60 332523 5

100 271 125 18 HAS-R-TZ M16x125/100 332524 540 269 170 25 HAS-R-TZ M20x170/40 335944 4

HAS-HCR-TZ Tije de ancorarecu mare rezistenţă la coroziune

Execuţie: cu piuliţă şi şaibă de susţinere.Material: oţel inoxidabil A4-80, indice material 1.4529

15 124 75 12 HAS-HCR-TZ M10x75/10* 336269 1030 139 75 12 HAS-HCR-TZ M10x75/30* 336270 1050 159 75 12 HAS-HCR-TZ M10x75/50* 336271 1025 158 95 14 HAS-HCR-TZ M12x95/25* 336272 1050 183 95 14 HAS-HCR-TZ M12x95/50* 336273 10

100 233 95 14 HAS-HCR-TZ M12x95/100* 336274 1030 181 105 18 HAS-HCR-TZ M16x105/30* 336275 560 211 105 18 HAS-HCR-TZ M16x105/60* 336276 5

100 251 105 18 HAS-HCR-TZ M16x105/100* 336277 530 201 125 18 HAS-HCR-TZ M16x125/30* 336278 560 231 125 18 HAS-HCR-TZ M16x125/60* 336279 5

100 271 125 18 HAS-HCR-TZ M16x125/100* 336280 540 269 170 25 HAS-HCR-TZ M20x170/40* 335945 4

* timpul de livrare se comunică la cerere

Dispozitiv de montaj pentru tije de ancorare HAS-TZ / R-TZ / HCR-TZ cu cap hexagonal

Pentrudimensiune HAS

Cap defixare

Codcomandă

Nr. articol Buc./ambalaj

M10 TE-C TE-C HEX M10 311415 1M12 TE-C TE-C HEX M12 311416 1M16 TE-C TE-C HEX M16 311417 1M20 TE-Y TE-Y HEX M20 336420 1

HAS-TZ Tije de ancorare – lungimi speciale

Înălţimede fixare

Lungimetijă (mm)

Adâncime depozare (mm)

Codcomandă

Nr. articol Buc./ambalaj

x nominalburghiu (mm)

Înălţimede fixare

Lungimetijă (mm)

Adâncime depozare (mm)

Codcomandă

Nr. articol Buc./ambalaj

x nominalburghiu (mm)

Confecţionăm în scurt timp orice lungime specială dorită de Dumneavoastră. Preţurile şi timpul de livrare se comunică la cerere!

131

Tehn

ica

anco

rări

i

Ancore pentru sarcini mari / Chimice

Page 3: Ancore Chimice Mecanice Pentru Sarcinimari

9 HVA Ancoră chimicăpentru sarcini mari în zona comprimată

Timp de întărireTemperatură în gaură ³ + 20 °C ³ + 10 °C ³ 0 °C ³ - 5 °CInterval de aşteptare între poziţionare şi încărcare 20 min. 30 min. 1 oră 5 ore

Date tehniceValorile sarcinilor conform Manualului tehnicii de fixare Hilti şi Eurocode (procedura CC):

HVA/HVU cu HAS tijă de ancorare M8 M10 M12 M16 M20 M24 M27 M30 M33 M36 M39

Suprafaţă de ancorare Beton fără fisuri C20/251) Solicitare la tracţiune admisă N [kN] 7,8 11,8 17,0 24,8 44,9 64,7 79,2 104,0 122,1 145,2 166,41) Solicitare la forfecare admisă V [kN] 5,6 9,0 13,1 24,7 38,6 55,6 117,1 142,4 177,4 208,2 250,4Distanţă necesară faţă de margine Ccr [cm] 8,0 9,0 11,0 12,5 17,0 21,0 24,0 27,0 30,0 33,0 36,0Distanţă necesară între axe Scr [cm] 16,0 18,0 22,0 25,0 34,0 42,0 48,0 54,0 60,0 66,0 72,02) Distanţă minimă faţă de margini Cmin [cm] 4,0 4,5 5,5 6,3 8,5 10,5 12,0 13,5 15,0 16,5 18,02) Distanţă minimă între axe Smin [cm] 4,0 4,5 5,5 6,3 8,5 10,5 12,0 13,5 15,0 16,5 18,0Diametru gaură d0 [mm] 10 12 14 18 24 28 30 35 37 40Adâncime gaură h1 [cm] 8 9 11 12,5 17 21 24 27 30 33

Gaură de trecere [mm]10 12 14 17 22 27 30 34 38 41

ho

h

do

1) Sarcinile admisibile sunt valabile pentru fixări individuale la distanţă faţă de margini, cu armătură densă, coeficient parţial de siguranţă al aplicării forţei 1,42) Sarcinile admisibile trebuiesc reduse în conformitate cu procedura CC,conform Manualului tehnicii de ancorare Hilti. Informaţii suplimentare puteţi găsi în Manualul tehnicii de ancorare Hilti, sau pe Internet la adresa www.hilti.ro.

HVU Cartuşe pentru ancore chimiceAvantaje:nMontaj simplu şi rapid.nCartuş flexibil – se potriveşte şi în găuri curbe.nCartuş rezistent la rupere – nu există pericolul rănirii.nDepozitare uşoară – nu este posibilă spargerea.nCartuş în formă de săgeată – cartuşul rămâne atârnat în gaură (fixări în tavan).nValori mari de sarcină, valorificarea rezistenţei barelor de oţel, deplasare optimă a sarcinilor,

rezistenţă în timp, comportament optim în caz de incendiu.nNu prezintă tendinţă de contracţie, ceea ce oferă o mare siguranţă timp îndelungat.nNou sistem hibrid: fără stiren şi aditivi de înmuiere, ceea ce îl face fără miros.

HVU Cartuş pentru ancoră chimică

HAS / HAS-R Tijă de ancorare

HAS-E / HAS-ER Tijă de ancorare

Moment de strângere Tinst [Nm]11 13 15 19 25 29 31 36 38 41

Deschidere cheie SW [mm]

Grosime minimă element de construcţie hmin [cm]

42364543

18 35 60 120 260 450 650 950 1200 1500 4313 17 19 24 30 36 41 46 50 55 59

132

Ancore pentru sarcini mari / Chimice

Page 4: Ancore Chimice Mecanice Pentru Sarcinimari

q0 Tijă de ancorare HIT-TZ / HIT-RTZ şi mortar de injecţie HIT-HY 150

Sistemul de injecţie pentru beton cu fisuri

Avantaje:n

n

n

n

Sigur: independent de starea găurii – murdară, umedă, perforată cu diamantSiguranţă: sprijin ulterior sigur în fisură, potrivit pentru zona întinsă (tavan)Utilizare uşoară: funcţionează cu mortarul de injecţie clasic HIT-HY 150Economic: adâncime de încastrare redusă (circa 30% mai mică decât la tijele de ancorare HAS)

Procedură de pozare:

Conform aprobării DlBt, pentru HIT-TZ M16 şi HIT-TZ M20 gaura trebuie curăţată (2 x pompare / 2 curăţare cu peria / 2 x pompare)

137

Date tehniceExtras din aprobarea ETA: ETA-03/0084

HIT-HY 150 şi HIT-TZ Tije de ancorare M8 M10 M12 M16 M20

Material de ancorare Beton C20/251) Solicitare la tracţiune admisă (zonă comprimată) N [kN] 7,6 9,5 14,3 19,0 23,91) Solicitare la tracţiune admisă (zonă întinsă) N [kN] 4,3 5,7 7,6 9,5 16,61) Solicitare la forfecare admisă V [kN] 6,3 9,7 14,3 26,9 41,7Distanţă necesară faţă de margine Ccr [cm] 11 13 15 18 24Distanţă necesară între axe Scr [cm] 22 26 30 36 482) Distanţă minimă faţă de margini Cmin [cm] 5 6 7 8 102) Distanţă minimă între axe Smin [cm] 5 6 7 8 10Diametru gaură do [mm] 10 12 14 18 22Adâncime gaură h1 [cm] 6 7 8 9,5 12,5Grosime min. element de construcţie hmin [cm] 11 13 15 18 24Gaură de trecere [mm] 11 13 15 19 23Moment de strângere Tinst [Nm] 12 23 40 70 130Deschidere cheie SW [mm] 13 17 19 24 301) Sarcinile admisibile sunt valabile pentru fixări individuale la distanţă faţă de margini, cu armătură densă, coeficient parţial de siguranţă al aplicării forţei 1,42) Sarcinile admisibile trebuie reduse în conformitate cu aprobarea ETA

Informaţii suplimentare puteţi găsi în Manualul tehnicii de ancorare Hilti, sau pe Internet la adresa www.hilti.ro.

HIT-HY 150 Mortar de injecţie HIT-TZ Tijă ancoră injectată

Ancore pentru sarcini mari / Chimice

1 2 3 4 5a 5b 6

HY 150HY 150

HY 150

HY 150

tcure

~0,5

hno

m

hnom

hnom

hnom

Tehn

ica

anco

rări

i

Page 5: Ancore Chimice Mecanice Pentru Sarcinimari

138

HIT-HY 150 Mortar de injecţie

330 2 Mixere HIT-HY 150/330 334539 1500 2 Mixere HIT-HY 150/500 338973 20

HIT-TZ Tije de ancorare

Execuţie: cu piuliţă şi şaibă de susţinereMaterial: oţel 6.8, zincat galvanic

10 60 55 15 82 HIT-TZ M 8 55/15 284796 4010 60 55 40 107 HIT-TZ M 8 55/40 284797 4012 70 65 15 93 HIT-TZ M 10 65/15 337476 4012 70 65 40 118 HIT-TZ M 10 65/40 337477 4014 80 75 15 106 HIT-TZ M 12 75/15 337478 2014 80 75 30 121 HIT-TZ M 12 75/30 284801 2014 80 75 50 141 HIT-TZ M 12 75/50 337479 2018 95 90 25 136 HIT-TZ M 16 90/25 337480 1018 95 90 60 171 HIT-TZ M 16 90/60 337481 1022 125 120 30 174 HIT-TZ M 20120/30 337482 622 125 120 60 204 HIT-TZ M 20120/60 337483 6

HIT-RTZ Tije de ancorare

Execuţie: cu piuliţă şi şaibă de susţinereMaterial: oţel inoxidabil A4, indice material 1.4404

10 60 55 15 HIT-RTZ M 8 55/15 284798 4010 60 55 40 HIT-RTZ M 8 55/40 284799 4012 70 65 15 HIT-RTZ M 10 65/15 337490 4012 70 65 40 HIT-RTZ M 10 65/40 337491 4014 80 75 15 HIT-RTZ M 12 75/15 337492 2014 80 75 30 HIT-RTZ M 12 75/30 337817 2014 80 75 50 HIT-RTZ M 12 75/50 337493 2018 95 90 25 HIT-RTZ M 16 90/25 337494 1018 95 90 60 HIT-RTZ M 16 90/60 337495 1022 125 120 30 HIT-RTZ M 20120/30 337496 622 125 120 60

82107

93118106121141136171174204 HIT-RTZ M 20120/60 337497 6

Ancore pentru sarcini mari / Chimice

Conţinut(ml)

Codcomandă

Nr. articol Buc. /ambalaj

Inclusiv

x gaurăd (mm)0

Codcomandă

Nr. articol Buc. /ambalaj

Adâncimegaură h (mm)1

Adâncime depozare h (mm)nom

Înălţime defixare t (mm)fix

Lungimetijă (mm)

x gaurăd (mm)0

Codcomandă

Nr. articol Buc. /ambalaj

Adâncimegaură h (mm)1

Adâncime depozare h (mm)nom

Înălţime defixare t (mm)fix

Lungimetijă (mm)

Page 6: Ancore Chimice Mecanice Pentru Sarcinimari

Set dinamic

Codcomandă

Nr. articol Buc./ambalaj

Dynamic Set M10* 369201 2Dynamic Set M12 369202 2Dynamic Set M16 369203 2Dynamic Set M20 369204 2

1)HIT-HY 150/330 334539 1* timp de livrare la cerere1) pentru umplerea fantei inelare dintre tija de ancorare şi gaura de trecere a plăcii de ancoratAncoră cu autotăiere HDA qa, ancoră chimică HVZ 8

141

qsHVZ / HDA Seturi dinamice

n

n

n

n

Combinarea ancorelor verificate HDA + HVZ cu setul dinamic.

Ancoraj sigur al sarcinilor dinamice

Montaj simplu şi rapid

Nou concept de dimensionare

Date tehnice pentru set dinamic HDA

HDA-dynamic inclusiv set dinamic M10 M12 M16Număr aprobare Z-21, 1-1693 din 04.09.2001Material de ancorare Beton cu şi fără fisuri ≥ C20 / 25, resp. ≥ B25

HDA-P HDA-T HDA-P HDA-T HDA-P HDA-TÎncărcare admisă „ΔN“pt diblu individual la dist. faţă de margine [kN] 6,7 11,8 22,9Încărcare admisă „ΔV“pt diblu individual la dist. faţă de margine [kN] 2,0 6,3 4,5 11,3 6,1 17,31) Distanţa între axe Scr [cm] 30 37,5 571) Distanţa faţă de margine [cm] 15 19 28,51) Distanţa minimă între axe Smin[cm] 10 12,5 191) Distanţa minimă faţă de margine Cmin[cm] 8 10 15Adâncime de ancorare hef [cm] 10 12,5 19Grosime minimă element de construcţie hmin [cm] 20 25 38Cuplu de torsiune la ancorare [Nm] 50 80 120

Seturi dinamice pentru sarcini mari

HVU-TZ Cartuş pentru ancoră chimică

HAS-TZ / HAS-R TZ Tijă de ancorare

HDA P Ancoră cu autotăiere

Compus din şaibă de umplere, şaibă tip calotă, piuliţă şi piuliţă de siguranţă

Extras din condiţiile de utilizare ale aprobărilor Z-21, 1-1693 (HDA-dynamic) conform procedurii de dimensionare A (ETAG anexa C).

Sarcinile sunt valabile pentru un singur diblu fără influenţe marginale, în beton ≥ C20 / 25, resp. ≥ B25. Vă rugăm să luaţi valorile caracteristice de sarcină menţionate în aprobare.

1) Dacă distanţa faţă de margini este mai mică decât 10xhef, respectiv se efectuează o fixare multiplă, încărcările se vor stabili conform aprobării Z-21, 1-1693: Programul Hilti de dimensionare a diblurilor

Date tehnice pentru set dinamic HVZ

HVZ-dynamic inclusiv set dinamic M10x75 M12x95 M16x105 M16x125Număr aprobare Z-21, 3-1692 din 01.04.2003Material de ancorare Beton cu şi fără fisuri ≥ C20 / 25, resp. ≥ B25Încărcare admisă „ΔN“pt diblu individual la dist. faţă de margine [kN]

3,37,4

6,312,3

11,114,3

11,118,5

Încărcare admisă „ΔV“pt diblu individual la dist. faţă de margine [kN]22,5 28,5 31,5 37,5

1) Distanţa între axe Scr [cm]11,5 14,5 16 19

1) Distanţa faţă de margine [cm]6 7,5 8,5 8,5

1) Distanţa minimă între axe Smin[cm]6 7,5 8,5 8,5

1) Distanţa minimă faţă de margine Cmin[cm]7,5 9,5 10,5 12,5Adâncime de ancorare hef [cm]15 19 21 25Grosime minimă element de construcţie hmin [cm]40 50 90 90Cuplu de torsiune la ancorare [Nm]

Extras din condiţiile de utilizare ale aprobărilor Z-21, 3-1692 (HVZ-dynamic) conform procedurii de dimensionare A (ETAG anexa C).

Sarcinile sunt valabile pentru un singur diblu fără influenţe marginale, în beton ≥ C20 / 25, resp. ≥ B25. vă rugăm să luaţi valorile caracteristice de sarcină menţionate în aprobare.

1) Dacă distanţa faţă de margini este mai mică decât 10xhef, respectiv se efectuează o fixare multiplă, încărcările se vor stabili conform aprobării Z-21, 1-1693: Programul Hilti de dimensionare a diblurilor

Tehn

ica

anco

rări

i

Page 7: Ancore Chimice Mecanice Pentru Sarcinimari

142

Avantaje:

Date tehnice

Extras din aprobarea ETA: ETA-02/0042HSL-3 M8 M10 M12 M16 M20 M24Material de ancorare Beton C20/251) Sarcină tracţiune adm. (zonă comp.) N [kN] 11,1 14,0 17,2 24,0 33,5 44,11) Sarcină tracţiune adm. (zonă întinsă) N [kN] 4,8 7,6 12,3 17,1 24,0 31,51) Sarcină forfecare admisă V [kN] 17,8 28,1 41,0 57,8 81,1 101,4Distanţă necesară faţă de margine Ccr [cm] 9 10,5 12 15 18,8 22,5Distanţă necesară între axe Scr [cm] 18 21 24 30 37,5 452) Distanţă minimă faţă de margini Cmin [cm] 6 7 8 10 15 152) Distanţă minimă între axe Smin [cm] 6 7 8 10 12,5 15Diametru gaură do [mm] 12 15 18 24 28 32Adâncime gaură h1 [cm] 8 9 10,5 12,5 15,5 18Grosime min. element de construcţie hmin [cm] 12 14 16 20 25 30Gaură de trecere [mm] 14 17 20 26 31 35Moment strângere Tinst [Nm] HSL-3/HSL-3G 25/20 50/35 80/60 120/80 200/160 250Deschidere cheie SW [mm] 13 17 19 24 30 36

qd HSL-3 Ancoră pentru sarcini mari

Siguranţă pentru sarcini mari

Material: Aprobare Protecţie antifocnBeton cu şi fără fisuri ETA-02/0042

Utilizare:nPentru sarcini mari, de ex. stâlpi, maşini , echipamente

HSL-3 Ancoră pentru sarcini mari

Execuţie:nCu şurub hexagonal şi şaibă suport

Material:n

n

Oţel , zincat galvanic, şurub filetat.Clasă de rezistenţă a şurubului 8.8

5 12 80 60 14 13 HSL-3 M8/5 371774 4020 12 80 60 14 13 HSL-3 M8/20 371775 4040 12 80 60 14 13 HSL-3 M8/40 371776 40

5 15 90 70 17 17 HSL-3 M10/5 371777 2020 15 90 70 17 17 HSL-3 M10/20 371778 2040 15 90 70 17 17 HSL-3 M10/40 371779 20

5 18 105 80 20 19 HSL-3 M12/5 371780 2025 18 105 80 20 19 HSL-3 M12/25 371781 2050 18 105 80 20 19 HSL-3 M12/50 371782 1010 24 125 100 26 24 HSL-3 M16/10 371783 1025 24 125 100 26 24 HSL-3 M16/25 371784 1050 24 125 100 26 24 HSL-3 M16/50 371785 1010 28 155 125 31 30 HSL-3 M20/10 371786 630 28 155 125 31 30 HSL-3 M20/30 371787 660 28 155 125 31 30 HSL-3 M20/60 371788 610 32 180 150 35 36 HSL-3 M24/10 371789 430 32 180 150 35 36 HSL-3 M24/30 371790 460 32 180 150 35 36 HSL-3 M24/60 371791 4

Ancore pentru sarcini mari/ Metalice

IBMB 3027/027-5

Indicaţii de montaj:

Marcajuladâncimiide pozare

n

n

n

n

Cele mai bune valori de sarcină la încărcări transversale şi de tracţiuneManşon masiv, închis, al dibluluiElement de material plastic integrat:- împiedică rotirea accidentală- prindere strânsă a elementului de racordEste posibilă tensionarea ulterioară

1) Sarcinile admisibile sunt valabile pentru fixări individuale la distanţă faţă de margini, cu armătură densă, coeficient parţial de siguranţă al aplicării forţei 1,42) Sarcinile admisibile trebuie reduse în conformitate cu aprobarea ETA Informaţii suplimentare puteţi găsi în Manualul tehnicii de ancorare Hilti, sau pe Internet la adresa www.hilti.ro.

Înălţimede fixaret (mm)fix

Adâncimemin. gaurăh (mm)1

Adâncimeefectivă deancorare h (mm)ef

Codcomandă

x nominalburghiu (mm)d (mm)0

Nr. articol Buc. /ambalaj

Gaurăde trecere(mm)

DeschiderecheieSW (mm)

Page 8: Ancore Chimice Mecanice Pentru Sarcinimari

143

HSL-3-G Ancoră pentru sarcini mari

Execuţie:nCu tijă filetată, şaibă suport şi piuliţă

Material: nOţel, zincat galvanic.

5 12 80 60 14 13 HSL-3-G M8/5 371792 4020 12 80 60 14 13 HSL-3-G M8/20 371793 4040 12 80 60 14 13 HSL-3-G M8/40 371794 40

100 12 80 60 14 13 HSL-3-G M8/100 371829 205 15 90 70 17 17 HSL-3-G M10/5 371795 20

20 15 90 70 17 17 HSL-3-G M10/20 371796 2040 15 90 70 17 17 HSL-3-G M10/40 371797 20

100 15 90 70 17 17 HSL-3-G M10/100 371830 205 18 105 80 20 19 HSL-3-G M12/5 371798 20

25 18 105 80 20 19 HSL-3-G M12/25 371799 2050 18 105 80 20 19 HSL-3-G M12/50 371800 10

100 18 105 80 20 19 HSL-3-G M12/100 371831 1010 24 125 100 26 24 HSL-3-G M16/10 371801 1025 24 125 100 26 24 HSL-3-G M16/25 371802 1050 24 125 100 26 24 HSL-3-G M16/50 371803 10

100 24 125 100 26 24 HSL-3-G M16/100 371832 1010 28 155 125 31 30 HSL-3-G M20/10 371804 630 28 155 125 31 30 HSL-3-G M20/30 371805 660 28 155 125 31 30 HSL-3-G M20/60 371806 6

100 28 155 125 31 30 HSL-3-G M20/100 371833 630 32 180 150 35 36 HSL-3-G M24/30 324930 4

Ca execuţie specială, sunt posibile HSL-3-G cu alte înălţimi de fixare şi adâncimi de ancorare.Preţurile şi timpul de livrare se comunică la cerere.

Piuliţe inelare*

zincate, DIN 582, calitate C15, încărcare conform DIN 582

20 36 1,4 0,95 Ri M 8 58202 5025 45 2,3 1,7 Ri M 10 58203 5030 54 3,4 2,4 Ri M 12 58204 5035 63 7,0 5,0 Ri M 16 58206 5040 72 12,0 8,3 Ri M 20 58207 2550 90 18,0 12,7 Ri M 24 58208 20* nu sunt permise încărcările transversale pe axa inelului.

Ancore pentru sarcini mari/ Metalice

Marcajuladâncimiide pozare

Înălţimede fixaret (mm)fix

Adâncimemin. gaurăh (mm)1

Adâncimeefectivă deancorare h (mm)ef

Codcomandă

x nominalburghiu (mm)d (mm)0

Nr. articol Buc. /ambalaj

Gaurăde trecere(mm)

DeschiderecheieSW (mm)

x interiorinel (mm)

Pentru opiuliţă (kN)

Pentru 2 piuliţeîn total (kN)

Codcomandă

x exteriorinel (mm)

Nr. articol Buc. /ambalaj

Tehn

ica

anco

rări

i

Page 9: Ancore Chimice Mecanice Pentru Sarcinimari

144

Avantaje:n

n

n

Nu este necesară o cheie dinamometrică pentru montajSiguranţă foarte mare a montajuluiControl optic al montajului

Avantaje:nŞurubul cu cap hexagonal interior face posibil montajul în condiţii

de spaţiu redus

HSL-3-B Ancoră pentru sarcini mari

Execuţie:nCu piuliţă de control: la atingerea momentului de

strângere prestabilit piuliţa roşie de control se desprinde prin forfecare. Apoi devine vizibilă o plombă din material plastic verde, care indică faptul că diblul este ancorat perfect.

Material:

HSL-3-SH Ancoră pentru sarcini mari

Execuţie:nCu şurub cu cap hexagonal interior

Utilizare:nPentru sarcini mari, special pentru montaje în care din raţiuni de

spaţiu nu se pot utiliza cheia inelară sau cheia fixă, de ex. montajul de şine.

Material:n

n

Oţel, zincat galvanic, , şurub filetatClasă de rezistenţă a şurubului 8.8

5 18 105 80 20 24 HSL-3-B M12/5 371807 2025 18 105 80 20 24 HSL-3-B M12/25 371808 2050 18 105 80 20 24 HSL-3-B M12/50 371809 1010 24 125 100 26 30 HSL-3-B M16/10 371810 1025 24 125 100 26 30 HSL-3-B M16/25 371811 1050 24 125 100 26 30 HSL-3-B M16/50 371812 1010 28 155 125 31 36 HSL-3-B M20/10 371813 630 28 155 125 31 36 HSL-3-B M20/30 371814 660 28 155 125 31 36 HSL-3-B M20/60 371815 610 32 180 150 35 41 HSL-3-B M24/10 371816 430 32 180 150 35 41 HSL-3-B M24/30 371817 460 32 180 150 35 41 HSL-3-B M24/60 371818 4

5 12 80 60 14 6 HSL-3-SH M8/5 377341 6020 15 90 70 17 8 HSL-3-SH M10/20 377342 4025 18 105 80 20 10 HSL-3-SH M12/25 377343 20

Ancore pentru sarcini mari/ Metalice

nOţel zincat galvanic, şurub filetatClasă de rezistenţă a şurubului 8.8.

Marcajuladâncimiide pozare

Înălţimede fixaret (mm)fix

Adâncimemin. gaurăh (mm)1

Adâncimeefectivă deancorare h (mm)ef

Codcomandă

x nominalburghiu (mm)d (mm)0

Nr. articol Buc. /ambalaj

Gaurăde trecere(mm)

DeschiderecheieSW (mm)

Înălţimede fixaret (mm)fix

Adâncimemin. gaurăh (mm)1

Adâncimeefectivă deancorare h (mm)ef

Codcomandă

x nominalburghiu (mm)d (mm)0

Nr. articol Buc. /ambalaj

Gaurăde trecere(mm)

DeschiderecheieSW (mm)

Page 10: Ancore Chimice Mecanice Pentru Sarcinimari

145

Avantaje:Nu există pericol de împiedicare, aspect optic plăcut, datorită montajului la acelaşi nivel cu suprafaţa.

HSL-3-SK Ancoră pentru sarcini mari

Execuţie:nCu şurub cu cap înecat (similar DIN 7991)

Utilizare:nAncorări pt. sarcini mari la acelaşi nivel cu suprafaţa elementului montat.

Material:nOţel, zincat galvanic

10 12 75 60 14 24 6 6 HSL-3 M 8/10 SK 371825 4020 12 80 60 14 24 6 6 HSL-3 M 8/20 SK 371826 4020 15 90 70 17 27 8 6 HSL-3 M10/20 SK 371827 2025 18 100 80 20 33 10 7,5 HSL-3 M12/25 SK 371828 20

90°

HSL-G-R Ancoră pentru sarcini mari, inoxidabilă

Execuţie: cu tijă filetată, şaibă suport şi piuliţă, material - oţel inoxidabil A4,(indice material 1.4401)

20 12 80 60 14 13 HSL-G-R M8/20 67920 4020 15 90 70 17 17 HSL-G-R M10/20 67922 2025 18 105 80 20 19 HSL-G-R M12/25 67924 2025 24 125 100 26 24 HSL-G-R M16/25 67926 1030 28 155 125 31 30 HSL-G-R M20/30 67928 6

Nu este inclus în aprobarea ETA

Fixări speciale – sarcini mari

GW Vinclu pentru schelă, pentru schele în consolă

Sistem de ancoraj al schelei

Pentru beton începând de la C 20/25

GW 160-100 Vinclu pentru schelă 1HSL-3-B M 12/50 10

Pentru geometria găurii – a se vedea mai sus.Pentru utilizări pe suprafeţe din cărămidă plină vă rugăm să vă adresaţi tehnicienilor noştri.

Ancore pentru sarcini mari/ Metalice / fixări speciale

h

d1

Înălţ. max.de fixaret (mm)fix

Adâncimemin. gaurăh (mm)1

Adâncime efectivăde ancorareh (mm)ef

Codcomandă

x nominalburghiu (mm)d (mm)0

Nr. articol Buc. /ambalaj

Gaurăde trecere(mm)

x capd (mm)1

Gaură interioarăhexagonalăSW (mm)

Înălţimecap h (mm)

Înălţ. max.de fixaret (mm)fix

Codcomandă

Adâncimemin. gaurăh (mm)1

58751371809

Nr. articol

Adâncime efectivăde ancorareh (mm)ef

Codcomandă

x nominalburghiu (mm)d (mm)0

Nr. articol Buc. /ambalaj

Buc. /ambalaj

Gaurăde trecere(mm)

DeschiderecheieSW (mm)

Tehn

ica

anco

rări

i

Page 11: Ancore Chimice Mecanice Pentru Sarcinimari

HDA - Dimensions

HDA-T cut-out for setting / removal tool, turned through 90° d S1d S 2 d S 3

d B

d C

AF Sl

Bl

HDA-P cut-out for setting /removal tool, turned through 90° d S1d S 2 d S 3

d B

d C

AF S l

Bl

Anchor tfix

[mm] lB

[mm] Length code

lS [mm]

AF [mm]

dS1 [mm]

dS2 [mm]

dS3 [mm]

dC [mm]

dB [mm]

HDA-P/PR/PF20-M10*100/20 20 150 I 100 17 19 16.8 18.5 19.5 10 HDA-T/TR/TF 20-M10*100/20 20 150 I 120 17 19 16.8 18.5 19.5 10 HDA-P/PR/PF 22-M12*125/30 30 190 L 125 19 21 18.8 20.5 21.4 12 HDA-P/PR/PF 22-M12*125/50 50 210 N 125 19 21 18.8 20.5 21.4 12 HDA-T/TR/TF 22-M12*125/30 30 190 L 155 19 21 18.8 20.5 21.4 12 HDA-T /TR/TF22-M12*125/50 50 210 N 175 19 21 18.8 20.5 21.4 12 HDA-P/PR/PF 30-M16*190/40 40 275 R 190 24 29 26 29 29 16 HDA-P/PR/PF 30-M16*190/60 60 295 S 190 24 29 26 29 29 16 HDA-T/TR/TF 30-M16*190/40 40 275 R 230 24 29 26 29 29 16 HDA-T/TR/TF 30-M16*190/60 60 295 S 250 24 29 26 29 29 16 HDA-P 37-M20*250/50 50 360 V 350 30 35 32 35 36 20 HDA-P 37-M20*250/100 100 410 X 250 30 35 32 35 36 20 HDA-T 37-M20*250/50 50 360 V 300 30 35 32 35 36 20 HDA-T 37-M20*250/100 100 410 X 350 30 35 32 35 36 20

Page 12: Ancore Chimice Mecanice Pentru Sarcinimari

HDA - Dimensions

Stop bit

Stop bit t [mm] d0 [mm] connection end TE-C-HDA-B 20*100 107 20 TE-C TE-C-HDA-B 20*120 127 20 TE-C TE-C-HDA-B 22*125 134.5 22 TE-C TE-C-HDA-B 22*155 164.5 22 TE-C TE-C-HDA-B 22*175 184.5 22 TE-C TE-Y-HDA-B 30*190 203 30 TE-Y TE-Y-HDA-B 30*230 243 30 TE-Y TE-Y-HDA-B 30*250 263 30 TE-Y TE-Y-HDA-B 37*250 261 37 TE-Y TE-Y-HDA-B 37*300 311 37 TE-Y TE-Y-HDA-B 37*350 361 37 TE-Y

Setting tool connection end

d

Setting tool d0 [mm] connection end TE-C-HDA-ST 20-M10 20 TE-C TE-C-HDA-ST 22-M12 22 TE-C TE-Y-HDA-ST 30-M16 30 TE-Y TE-Y-HDA-ST 37-M20 37 TE-Y

working length, t connection end

Ø d0

Page 13: Ancore Chimice Mecanice Pentru Sarcinimari

HIT-RE 500 injection adhesive with rebar

Issue 2005 245

3

Features: - base material: concrete

- injection system with high loading capacity

- good performance in diamond drilled holes

- good performance in wet holes

- suitable for water saturated concrete

- large diameter applications

- long working time at elevated temperatures

- odourless epoxy resin

- no expansion forces in base material

- small edge distance and anchor spacing

- clean and easy handling

Material:

Rebar:

- Type BSt 500 according to DIN 488 (See also

Euronorm 82-79.). For differing rebars, consult

your Hilti advisory service.

Cartridge:- Foil pack: 330 ml, 500ml

- Jumbo cartridge: 1100 ml

Dispenser:- MD2000, BD2000, P3000 F, MD2500, P3500 F, P5000 HY, HIT P-8000 D

Basic loading data (for a single anchor): HIT-RE 500 with rebar section

All data on this section applies to For detailed method, see page 248– 253. concrete: See table below. correct setting (See setting operations page 247) no edge distance, spacing and other influences

Rebar embedment depth [mm]: concrete = C20/25

Rebar diameter [mm] 8 10 12 14 16 20 25 28 32 36 40

Nominal anch. depth 80 90 110 125 125 170 210 270 300 330 360

Mean ultimate resistance, Ru,m [kN]: concrete = C20/25

Rebar diameter [mm] 8 10 12 14 16 20 25 28 32 36 40

Tensile, Concrete: NRu,m 33.4 46.9 68.8 91.3 104.3 177.3 273.8 344.4 407.2 462.2 515.7 Tensile, Steel: NRu,m 29.9 46.7 67.2 91.4 119.4 186.6 291.6 365.8 477.7 604.6 746.4 Shear, VRu,m 17.9 28.1 40.4 55.0 71.8 112.3 175.0 219.2 286.3 384.5 447.9

Characteristic resistance, Rk [kN]: concrete = C20/25

Rebar diameter [mm] 8 10 12 14 16 20 25 28 32 36 40

Tensile, Concrete: NRk 25.1 35.3 51.8 68.7 78.5 133.5 206.2 258.9 304.6 347.1 389.1 Tensile, Steel: NRk 25.1 39.3 56.5 77.0 100.5 157.1 245.4 307.9 402.1 508.9 628.3 Shear, VRk 16.7 26.0 37.4 50.9 66.5 104.0 162.0 203.0 265.1 356.0 414.6

HIT-RE 500 foil pack, mixer

Rebar section

Concrete Close edge distance / spacing

Fireresistance

Hilti Anchor programme

non-cracked concrete

Page 14: Ancore Chimice Mecanice Pentru Sarcinimari

246 Issue 2005

HIT-RE 500 injection adhesive with rebar

h1

h

d0

0 d /

Following values according to the

Concrete Capacity Method

Design resistance, Rd [kN]: concrete, fck,cube = 25 N/mm2

Rebar diameter [mm] 8 10 12 14 16 20 25 28 32 36 40

Tensile, NRd 13.9 19.7 28.8 38.2 43.7 74.2 114.5 143.9 169.2 192.8 216.1 Shear, VRd 11.1 17.3 24.9 33.9 44.3 69.3 108.0 135.3 176.7 237.3 276.4

Recommended load, Lrec [kN]: concrete, fck,cube = 25 N/mm2

Rebar diameter [mm] 8 10 12 14 16 20 25 28 32 36 40

Tensile, NRec 9.9 14.1 20.6 27.3 31.2 53.0 81.8 102.8 120.9 137.7 154.4 Shear, VRec 7.9 12.4 17.8 24.2 31.6 49.5 77.1 96.6 126.2 169.5 197.4

Setting details

Rebar diameter [mm] 8 10 12 14 16 20 25 28 32 36 40

d0 [mm] Drill bit diameter 10-12 12-14 16-18 18-20 20-22 25-28 30-32 35-37 39-42 42-48 48-52

h1 [mm] Hole depth 82 93 115 130 130 175 215 275 305 335 365

hnom [mm] Nominal anchorage depth 80 90 110 125 125 170 210 270 300 330 360

hmin [mm] Min. thickness of base material

100 120 140 170 170 220 270 340 380 410 450

ml 3-6 4-9 13-20 17-25 19-29 40-64 60-84 118-155 162 147 206 Filling volume1)

trigger pulls 1 1-2 2-4 3-5 4-6 8-13 12-17 24-31 32 30 41

TE- 1..18M 5..18M 15..35 25..55 35..55 55..76 55..76 55..76 55..76 55..76 55..76 Recommended drilling

system Diamond drill. DD EC-1, DD 100 DD 100, DD 130, DD 160 1) Holes must be filled approx. 2/3 rds.

Temprature of the basematerial:

Working time in which rebar can be inserted and adjusted

Curing time before rebar can be fully loaded

40°C30°C20°C10°C0°C-5°C

12 min. 20 min. 30 min. 2 hours 3 hours 4 hours

4 hours 8 hours 12 hours 24 hours 50 hours 72 hours

less than -5°C “not allowed”

The foil pack temperature must be at least +5°C.

Installation equipment

appropriate drill bit (diamond core bit) dispenser (MD 2000, BD 2000, P3000 F, P5000 HY, HIT P-8000 D) blow-out pump cleaning brushes

min

hnom

Page 15: Ancore Chimice Mecanice Pentru Sarcinimari

Issue 2005 247

3

HIT-RE 500 injection adhesive with rebar

Setting operations

Page 16: Ancore Chimice Mecanice Pentru Sarcinimari

HIT-RE 500 injection adhesive with rebar

248 Issue 2005

Anchor geometry and mechanical properties

Rebar [mm] 8 10 12 14 16 20 25 28 32 36 40

[mm] Nominal rebar diameter 8 10 12 14 16 20 25 28 32 36 40

As [mm²] Stressed cross-section 50.3 78.5 113.1 153.9 201.1 314.2 490.9 615.8 804.2 1017.9 1256.6

fuk [N/mm²]Nominal tensile strength

550

fyk [N/mm²] Yield strength 500

Detailed design method - Hilti CC

Caution: In view of the high loads transferable with HIT-RE 500, it must be verified by the user that the load acting on the concrete structure, including the loads introduced by the anchor fastening, do not cause failure, e.g. cracking, of the concrete structure.

TENSION

The design tensile resistance of a single anchor is the lower of

NRd,c : concrete cone/pull-out resistance

NRd,s : steel resistance

NRd,c: Concrete cone/pull-out resistance

W.satTempNR,NA,NB,To

cRd,cRd, ffffffNN

N0Rd,c: Concrete cone/pull-out resistance

concrete compressive strength, fck,cube = 25 N/mm2

Rebar [mm] Ø8 Ø10 Ø12 Ø14 Ø16 Ø20 Ø25 Ø28 Ø32 Ø36 Ø40

NoRd,c

1)[kN] Concrete 13.9 19.7 28.8 38.2 43.7 74.2 114.5 143.9 169.2 192.8 216.1

hnom [mm] Nominal anchorage depth 80 90 110 125 125 170 210 270 300 330 360 1) The design tensile resistance is calculated from the characteristic tensile resistance, No

Rk,c , by NoRd,c= No

Rk,c/ Mc,N, where the partial safety factor, Mc,N , is 1.8.

(The Hilti CC method is a simplified version of ETAG Annex C.)

anchorage depth addtional lengthaccording to application

d

N

cs

h

rec,c/s

Page 17: Ancore Chimice Mecanice Pentru Sarcinimari

HIT-RE 500 injection adhesive with rebar

Issue 2005 249

3

fT: Influence of anchorage depth

fB,N: Influence of concrete strength

Concrete strength designation(ENV 206)

Cylinder compressive strength,

fck,cyl [N/mm²]

Cube compressive strength,

fck,cube [N/mm²] fB,N

C20/25 20 25 1

C25/30 25 30 1.03

C30/37 30 37 1.06

C35/45 35 45 1.10

C40/50 40 50 1.13

C45/55 45 55 1.15

C50/60 50 60 1.18

Concrete cylinder: Height 30cm

Diameter 15cm

Concrete cube: side length 15 cm

Concrete test specimen geometry

fA,N: Influence of anchor spacing

Rebar size Anchorspacing,s [mm] Ø8 Ø10 Ø12 Ø14 Ø16 Ø20 Ø25 Ø28 Ø32 Ø36 Ø40

40 0.63 45 0.64 0.63 50 0.66 0.64 55 0.67 0.65 0.63 60 0.69 0.67 0.64 65 0.70 0.68 0.65 0.63 0.63 70 0.72 0.69 0.66 0.64 0.64 80 0.75 0.72 0.68 0.66 0.66 90 0.78 0.75 0.70 0.68 0.68 0.63

100 0.81 0.78 0.73 0.70 0.70 0.65 120 0.88 0.83 0.77 0.74 0.74 0.68 0.64 140 0.94 0.89 0.82 0.78 0.78 0.71 0.67 0.63 160 1.00 0.94 0.86 0.82 0.82 0.74 0.69 0.65 0.63 180 1.00 0.91 0.86 0.86 0.76 0.71 0.67 0.65 0.64 0.63 200 0.95 0.90 0.90 0.79 0.74 0.69 0.67 0.65 0.64 220 1.00 0.94 0.94 0.82 0.76 0.70 0.68 0.67 0.65 250 1.00 1.00 0.87 0.80 0.73 0.71 0.69 0.67 280 0.91 0.83 0.76 0.73 0.71 0.69 310 0.96 0.87 0.79 0.76 0.73 0.72 340 1.00 0.90 0.81 0.78 0.76 0.74 390 0.96 0.86 0.83 0.80 0.77 420 1.00 0.89 0.85 0.82 0.79 450 0.92 0.88 0.84 0.81 480 0.94 0.90 0.86 0.83 540 1.00 0.95 0.91 0.88 600 1.00 0.95 0.92 660 1.00 0.96 720 1.00

nom

actT

h

hf Limits to actual anchorage, hact: hnom hact 2.0 hnom

200

25f1f cube,ck

N,B

Limits: 25 N/mm² fck,cube 60 N/mm²

nomN,A

h4

s5.0f

Limits: smin s scr,N

smin = 0,5hnom

scr,N = 2,0hnom

Page 18: Ancore Chimice Mecanice Pentru Sarcinimari

HIT-RE 500 injection adhesive with rebar

250 Issue 2005

fR,N: Influence of edge distance

Rebar size Edgedistance,c [mm] Ø8 Ø10 Ø12 Ø14 Ø16 Ø20 Ø25 Ø28 Ø32 Ø36 Ø40

40 0.64 45 0.69 0.64 50 0.73 0.68 55 0.78 0.72 0.64 60 0.82 0.76 0.67 65 0.87 0.80 0.71 0.65 0.65 70 0.91 0.84 0.74 0.68 0.68 80 1.00 0.92 0.80 0.74 0.74 90 1.00 0.87 0.80 0.80 0.66

100 0.93 0.86 0.86 0.70 110 1.00 0.91 0.91 0.75 0.66 120 0.97 0.97 0.79 0.69 140 1.00 1.00 0.87 0.76 0.65 160 0.96 0.83 0.71 0.66 180 1.00 0.90 0.76 0.71 0.67 0.64 210 1.00 0.84 0.78 0.74 0.70 240 0.92 0.86 0.80 0.76 270 1.00 0.93 0.87 0.82 300 1.00 0.93 0.88 330 1.00 0.94 360 1.00

fTemp: Influence of base material temperature

Anchor setting: The Hilti HIT-RE 500 bond strength reduces when the anchor is set, cures and in service in a base material temperature range from –5 to +5°C. Hilti HIT-RE 500 adhesive shows a post curing effect. When the adhesive warms up to above +5°C, the bond will reach its full performance.

Service life: Base material temperatures above 50°C will lead to a decrease in Hilti HIT-RE 500 bond strength.

Base material temperature

fTemp

anchorsetting

ftemp

service life

-5 °C 0.8 1.0 0 °C 0.9 1.0 5°C 1.0 1.0

50°C - 1.0 60 °C - 0.85 70 °C - 0.62 80 °C - 0.5

Note:In case of an anchor fastening, which is made in base material at a temperature below +5°C and in service at a temperature over 50°C, only one influencing factor of the lower value should be applied.

fW.sat: Influence of water saturated concrete

0.7fW.sat

Note:The reduction shall only be applied, if the anchor is setted into water-saturated concrete, e.g. concrete members in water, filled water tanks, predrilled holes filled with water for more than 3 days. The reduction does not apply, if the concrete is subjected to short term water influence, e.g. diamond-cored holes.

nomN,R

h

c72.028.0f

Limits cmin c ccr,N

cmin= 0,5 hnom

ccr,N= 1,0 hnom

Note: If more than 3 edgesare smaller than ccr,N , consult your Hilti technical advisoryservice.

Page 19: Ancore Chimice Mecanice Pentru Sarcinimari

HIT-RE 500 injection adhesive with rebar

Issue 2005 251

3

NRd,s: Steel design tensile resistance

Rebar [mm] Ø8 Ø10 Ø12 Ø14 Ø16 Ø20 Ø25 Ø28 Ø32 Ø36 Ø40

NRd,s1) [kN] 20.9 32.7 47.1 64.1 83.8 130.9 204.5 256.6 335.1 424.1 523.6

1) The design tensile resistance is calculated from the characteristic tensile resistance, NRk,s , by NRd,s= As fuk/ Ms,N, where the partial safety factor, Ms,N , for rebar sections, type BSt 500, is 1.32.

NRd: System design tensile resistance

NRd = lower of NRd,c and NRd,s

Combined loading: Only if tensile load and shear load applied (See page 31 and section 4 “Examples”).

Detailed design method - Hilti CC

SHEAR

The design shear resistance of a single anchor is the lower of

VRd,c : concrete edge resistance

VRd,s : steel resistance

VRd,c: Concrete edge design resistance

The lowest concrete edge design resistance must be calculated. All near edges must be checked (not only the edge in the direction of shear). The direction of shear load is accounted for by the factor f ,V.

V,V,ARV,B0

c,Rdc,Rd fffVV

V0Rd,c: Concrete edge design resistance

concrete compressive strength, fck,cube = 25 N/mm2

at minimum edge distance minc

Rebar [mm] Ø8 Ø10 Ø12 Ø14 Ø16 Ø20 Ø25 Ø28 Ø32 Ø36 Ø40

VoRd,c

1) [kN] 2.0 3.6 5.0 7.1 7.3 12.5 18.8 30.2 37.7 45.0 54.0

cmin [mm] Min. edge distance 40 45 55 65 65 85 105 135 150 165 180 1) The design shear resistance is calculated from the characteristic shear resistance, Vo

Rk,c , by VoRd,c= Vo

Rk,c/ Mc,V, where the partial safety factor, Mc,V , is 1.5.

(The Hilti CC method is a simplified version of ETAG Annex C.)V

cs

rec,c/sc >1.5c2

c >1.5c2

h>1.5c

Note: If the conditions for h and c2 are not met, consult your Hilti technical advisory service.

Page 20: Ancore Chimice Mecanice Pentru Sarcinimari

HIT-RE 500 injection adhesive with rebar

252 Issue 2005

fB,V: Influence of concrete strength

Concrete strength designation(ENV 206)

Cylinder compressive strength,

fck,cyl [N/mm²]

Cube compressive strength,

fck,cube [N/mm²] fB,V

C20/25 20 25 1

C25/30 25 30 1.1

C30/37 30 37 1.22

C35/45 35 45 1.34

C40/50 40 50 1.41

C45/55 45 55 1.48

C50/60 50 60 1.55

Concrete cylinder:

Height 30cm,

Diameter 15cm

Concrete cube:

side length 15 cm

Concrete test specimen geometry

fAR,V: Influence of edge distance and spacing

c/cminfAR,V 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 3.2 3.4 3.6 3.8 4.0

Single-anchor with edge influence, 1.00 1.31 1.66 2.02 2.41 2.83 3.26 3.72 4.19 4.69 5.20 5.72 6.27 6.83 7.41 8.00

s/cmin 1.0 0.67 0.84 1.03 1.22 1.43 1.65 1.88 2.12 2.36 2.62 2.89 3.16 3.44 3.73 4.03 4.331.5 0.75 0.93 1.12 1.33 1.54 1.77 2.00 2.25 2.50 2.76 3.03 3.31 3.60 3.89 4.19 4.502.0 0.83 1.02 1.22 1.43 1.65 1.89 2.13 2.38 2.63 2.90 3.18 3.46 3.75 4.05 4.35 4.672.5 0.92 1.11 1.32 1.54 1.77 2.00 2.25 2.50 2.77 3.04 3.32 3.61 3.90 4.21 4.52 4.833.0 1.00 1.20 1.42 1.64 1.88 2.12 2.37 2.63 2.90 3.18 3.46 3.76 4.06 4.36 4.68 5.003.5 1.30 1.52 1.75 1.99 2.24 2.50 2.76 3.04 3.32 3.61 3.91 4.21 4.52 4.84 5.174.0 1.62 1.86 2.10 2.36 2.62 2.89 3.17 3.46 3.75 4.05 4.36 4.68 5.00 5.334.5 1.96 2.21 2.47 2.74 3.02 3.31 3.60 3.90 4.20 4.52 4.84 5.17 5.505.0 2.33 2.59 2.87 3.15 3.44 3.74 4.04 4.35 4.67 5.00 5.33 5.675.5 2.71 2.99 3.28 3.57 3.88 4.19 4.50 4.82 5.15 5.49 5.836.0 2.83 3.11 3.41 3.71 4.02 4.33 4.65 4.98 5.31 5.65 6.006.5 3.24 3.54 3.84 4.16 4.47 4.80 5.13 5.47 5.82 6.177.0 3.67 3.98 4.29 4.62 4.95 5.29 5.63 5.98 6.337.5 4.11 4.43 4.76 5.10 5.44 5.79 6.14 6.508.0 4.57 4.91 5.25 5.59 5.95 6.30 6.678.5 5.05 5.40 5.75 6.10 6.47 6.839.0 5.20 5.55 5.90 6.26 6.63 7.009.5 5.69 6.05 6.42 6.79 7.17

10.0 6.21 6.58 6.95 7.3310.5 6.74 7.12 7.5011.0 7.28 7.6711.5 7.8312.0 8.00

25

ff cube,ck

V,B

Limits: 25 N/mm2 fck,cube 60 N/mm2

These results are for a two-anchor fastening. For fastenings with two or more anchors, use the general formulae for n anchors.

Page 21: Ancore Chimice Mecanice Pentru Sarcinimari

HIT-RE 500 injection adhesive with rebar

Issue 2005 253

3

ccs

ss

2,2

1

2

3

n-1sc2,1

h >1,5 c

Note: It is assumed that only the row of anchors closest to the free concrete edge carries the centric shear load.

fAR,V: Influence of edge distance and spacing

Formula for single-anchor fastening influenced only by 1 edge

minminV,AR

c

c

c

cf

Formula for two-anchors fastening (edge plus 1 spacing) only valid for s < 3c

minminV,AR

c

c

c6

sc3f

General formula for n-anchor fastening (edge plus n-1 spacing) only valid when s1 and sn-1 are each < 3c and c2 > 1.5c

minmin

1n21V,AR c

c

cn3

s...ssc3f

f ,V : Influence of loading direction

Angle, ß [°] f ,V

0 to 55 1

60 1.1

70 1.2

80 1.5

90 to 180 2

VRd,s : Steel design shear resistance

Rebar [mm] Ø8 Ø10 Ø12 Ø14 Ø16 Ø20 Ø25 Ø28 Ø32 Ø36 Ø40

VRd,s1) [kN] 11.1 17.3 24.9 33.9 44.3 69.3 108.0 135.3 176.7 237.3 276.4

1) The steel design shear resistance is calculated from VRd,s= (0,6 As fuk)/ Ms,V. The partial safety factor, Ms,V , for rebar sections, type BSt 500, is 1.5.

VRd : System design shear resistance

VRd = lower of VRd,c and VRd,s

Combined loading: Only if tensile load and shear load applied (See page 31 and section 4 “Examples”).

1fV,

ßsin5,0ßcos

1f

V,

2fV,

for 0° ß 55°

for 55° < ß 90°

for 90° < ß 180°

Formulae:V ... applied shear force

results tabulatedbelow

Page 22: Ancore Chimice Mecanice Pentru Sarcinimari

HSL-3 heavy duty anchor

52

Features: - suitable for the tension zone - high loading capacity - force-controlled expansion - reliable pull-down of part fastened - no rotation in hole when tightening bolt Bolt Material:

- grade 8.8 acc. DIN EN ISO 898-1 galvanised to min. 5 microns

Versions: HSL-3 - bolt HSL-3-G - nut HSL-3-B - safety cap (automatic torque control) HSL-3-SK - countersunk head HSL-3-SH - socket head

Basic loading data (for a single anchor): HSL-3 / HSL-3-B / HSL-3-SH*/ HSL-3-SK* All data on this page applies to • concrete: as specified in the table • no edge distance and spacing influence • correct setting (See setting operations page 56) • steel failure

For detailed design method, see pages 57 – 61.

Mean ultimate resistance, Ru,m [kN]: concrete ≅ C20/25

Anchor size M8 M10 M12 M16 M20 M24 M8 M10 M12 M16 M20 M24 Tensile NRu,m

28.4 37.7 53.4 71.3 100.6 133.1 20.3 26.9 38.1 50.9 71.8 95.0 Shear VRu,m

43.0 63.5 88.9 128.6 160.6 239.7 43.0 63.5 88.9 128.6 160.6 239.7 Characteristic resistance, Rk [kN]: concrete ≅ C20/25

Anchor size M8 M10 M12 M16 M20 M24 M8 M10 M12 M16 M20 M24 Tensile NRk

23.4 29.5 36.1 50.4 70.4 92.6 16.7 21.1 25.8 36.0 50.3 66.1 Shear VRk

31.1 49.2 71.7 101.1 141.9 177.4 31.1 49.2 71.7 101.1 141.9 177.4 * HSL-3-SH, HSL-3-SK is only available up to M12

HSL-3

HSL-3-G

HSL-3-B

HSL-3-SK

HSL-3-SH

Concrete Tensile zone

Fire resistance

Hilti Anchor Programme

Close edge distance/ spacing

Fatigue Shock

cracked concrete non-cracked concrete

Page 23: Ancore Chimice Mecanice Pentru Sarcinimari

HSL-3 heavy duty anchor

53

Following values according to the:

Concrete Capacity Method Design resistance, Rd [kN]: concrete fck,cube = 25 N/mm2

Anchor size M8 M10 M12 M16 M20 M24 M8 M10 M12 M16 M20 M24 Tensile NRd

15.6 19.7 24.1 33.6 46.9 61.7 6.7 10.7 17.2 24.0 33.5 44.1 Shear VRd

24.9 39.4 57.4 80.9 113.5 141.9 24.9 39.4 57.4 80.9 113.5 141.9 Recommended load, Lrec [kN]: concrete fck,cube = 25 N/mm2

Anchor size M8 M10 M12 M16 M20 M24 M8 M10 M12 M16 M20 M24 Tensile NRec

11.1 14.0 17.2 24.0 33.5 44.1 4.8 7.6 12.3 17.1 24.0 31.5 Shear VRec

17.8 28.1 41.0 57.8 81.1 101.4 17.8 28.1 41.0 57.8 81.1 101.4 Basic loading data (for a single anchor): HSL-3 G All data on this section applies to • concrete: as specified in the table • no edge distance and spacing influence • correct setting (See setting operations page 56) • steel failure • For detailed design method, see pages 56 – 60.

Characteristic resistance, Rk [kN]: concrete ≅ C20/25

Anchor size M8 M10 M12 M16 M20 M8 M10 M12 M16 M20 Tensile NRk

23.4 29.5 36.1 50.4 70.4 16.7 21.1 25.8 36.0 50.3 Shear VRk

26.1 34.8 54.3 85.7 141.9 26.1 34.8 54.3 85.7 141.9 Following values according the:

Concrete Capacity Method Design resistance, Rd [kN]: concrete fck,cube= 25 N/mm2

Anchor size M8 M10 M12 M16 M20 M8 M10 M12 M16 M20 Tensile NRd

15.6 19.7 24.1 33.6 46.9 6.7 10.7 17.2 24.0 33.5 Shear VRd

20.9 27.8 43.4 68.6 113.5 20.9 27.8 43.4 68.6 113.5 Recommended load Lrec [kN]: fck,cube= 25 N/mm2

Anchor size M8 M10 M12 M16 M20 M8 M10 M12 M16 M20 Tensile NRec

11.1 14.0 17.2 24.0 33.5 4.8 7.6 12.3 17.1 24.0 Shear VRec

14.9 19.9 31.0 49.0 81.1 14.9 19.9 31.0 49.0 81.1 Installation equipment Rotary hammer (TE1, TE2, TE5, TE6, TE6A, TE15, TE15-C, TE18-M, TE35, TE55, TE76), hammer, torque wrench, blow out pump.

cracked concrete non-cracked concrete

Page 24: Ancore Chimice Mecanice Pentru Sarcinimari

HSL-3 heavy duty anchor

56

Setting details HSL-3

Anchor size M8/ tfix M10/ tfix M12/ tfix M16/ tfix M20/ tfix M24/ tfix

tfix [mm] Fastenable thickness (small/medium/large) 1) 5/20/40 5/20/40 5/25/50 10/25/50 10/30/60 10/30/60

d0 [mm] Nominal diameter of drill hole 12 15 18 24 28 32

[mm] Diameter of drill bit ≤ 12.5 ≤ 15.5 ≤ 18.5 ≤ 24.55 ≤ 28.55 ≤ 32.7 h1 [mm] Depth of drill hole 80 90 105 125 155 180

hef [mm] Effective anchorage depth 60 70 80 100 125 150

l [mm] Anchor length 2) tfix small tfix medium tfix large

83 98 118

95 110 130

111 131 156

138 153 178

163 183 213

185 205 235

[mm] Head height and washer 7.5 10 11 14 17 19

dw [mm] Washer diameter 20 25 30 40 45 50

hmin [mm] Min. base material thickness 120 140 160 200 250 300

df [mm] Clearance hole 14 17 20 26 31 35

SW [mm] Width across 13 17 19 24 30 36

Tinst [Nm] Torque moment 25 50 80 120 200 250

HSL-3-SH

Anchor size M8/ tfix M10/ tfix M12/ tfix

tfix [mm] Fastenable thickness 1) 5 20 25

d0 [mm] Nominal diameter of drill hole 12 15 18

[mm] Diameter of drill bit ≤ 12,5 ≤ 15,5 ≤ 18,5 h1 [mm] Depth of drill hole 85 95 110

hef [mm] Effective anchorage depth 60 70 80

l [mm] Anchor length 2) 88 120 142

[mm] Head height and washer 10 13 15

dw [mm] Washer diameter 20 25 30

hmin [mm] Min. base material thickness 120 140 160

df [mm] Clearance hole 14 17 20

SW [mm] Width across 6 8 10

Tinst [Nm] Torque moment 20 35 60

HSL-3-SK

Anchor size M8/ tfix M10/ tfix M12/ tfix

tfix [mm] Fastenable thickness (small/ /large) 1) 10/20 20 25

d0 [mm] Nominal diameter of drill hole 12 15 18

[mm] Diameter of drill bit ≤ 12,5 ≤ 15,5 ≤ 18,5 h1 [mm] Depth of drill hole 80 90 105

hef [mm] Effective anchorage depth 60 70 80

l [mm] Anchor length 2) 80/90 100 120

hmin [mm] Min. base material thickness 120 140 160

df [mm] Clearance hole 14 17 20

SW [mm] Size of hexagon socket screw key 6 8 10

Tinst [Nm] Torque moment 25 50 80

1) Other tfix possible 2) Other anchor length possible according to other tfix

1) Other tfix possible 2) Other anchor length possible according to other tfix

Page 25: Ancore Chimice Mecanice Pentru Sarcinimari

HSL-3 heavy duty anchor

56

HSL-3-G

Anchor size M8/ tfix M10/ tfix M12/ tfix M16/ tfix M20/ tfix

tfix [mm] Fastenable thickness (small/medium/large/ 100 mm) 1) 5/20/40/ 100

5/20/40/ 100

5/25/50/ 100

10/25/50/100

10/30/60/100

d0 [mm] Nominal diameter of drill hole 12 15 18 24 28 [mm] Diameter of drill bit ≤ 12,5 ≤ 15,5 ≤ 18,5 ≤ 24,55 ≤ 28,55

h1 [mm] Depth of drill hole 80 90 105 125 155

hef [mm] Effective anchorage depth 60 70 80 100 125

l [mm] Anchor length 2) tfix small tfix medium tfix large tfix = 100 mm

87 102 122 182

100 115 135 195

119 139 164 214

148 163 188 238

170 190 220 260

[mm] Head height and washer 8 11 13 17 20

dw [mm] Washer diameter 20 25 30 40 45

hmin [mm] Min. base material thickness 120 140 160 200 250 df [mm] Clearance hole (through setting) 14 17 20 26 31 df [mm] Clearance hole (only threaded rod carries the load) 9 12 14 18 22

SW [mm] Width across 13 17 19 24 30

Tinst [Nm] Torque moment 20 35 60 80 160

1) Other tfix possible 2) Other anchor length possible according to other tfix

Page 26: Ancore Chimice Mecanice Pentru Sarcinimari

HSL-3 heavy duty anchor

56

HSL-3-B

Anchor size M12/ tfix M16/ tfix M20/ tfix M24/ tfix

tfix [mm] ( small / medium / large) 1) 5/25/50 10/25/50 10/30/60 10/30/60

d0 [mm] Nominal diameter of drill hole 18 24 28 32

[mm] Diameter of drill bit ≤ 18.5 ≤ 24.55 ≤ 28.55 ≤ 32.7 h1 [mm] Depth of drill hole 105 125 155 180

hef [mm] Effective anchorage depth 80 100 125 150

l [mm] Anchor length 2) tfix small tfix medium tfix large

117 137 162

144 159 184

169 189 219

191 211 241

[mm] Head height and washer 16.5 19.5 22.5 24.5

dw [mm] Washer diameter 30 40 45 50

hmin [mm] Min. base material thickness 160 200 250 300

df [mm] Clearance hole 20 26 31 35

SW [mm] Width across 24 30 36 41

Tinst [Nm] Torque moment - - - -

1) Other tfix possible 2) Other anchor length possible according to other tfix

hmin h1

hef

Tinst.

tfix

Page 27: Ancore Chimice Mecanice Pentru Sarcinimari

HSL-3 heavy duty anchor

57

Setting operations

1

2

3

4

Drill hole. Blow out dust and fragments. Install anchor. Apply tightening torque (for HSL-3-B: no torque wrench is

needed) Anchor mechanical properties

Anchor size M8 M10 M12 M16 M20 M24

fuk [N/mm2] Nominal tensile strength 800 800 800 800 830 830

fyk [N/mm2] Yield strength 8.8 640 640 640 640 640 640

As [mm2] Stressed crossed-section 36.6 58.0 84.3 157.0 245.0 353.0

W [mm2] Elastic moment of resistance 30 60 105 266 519 898

Mrec [Nm] Recommended bending moment without sleeve 12.5 24.9 43.7 111.0 216.4 374.2

Detailed design method - Hilti CC

TENSION The tensile design resistance of a single anchor is the lower of,

NRd,p : concrete pull-out resistance NRd,c : concrete cone resistance NRd,s : steel resistance

NRd,p : Pull-out resistance Pull-out failure mode is only determinating for the anchor sizes M8 and M10 in cracked concrete

Bo

p,Rdp,Rd fNN ⋅= • Concrete compressive strength. fck.cube(150) = 25 N/mm2 Anchor size M8 M10

N0Rd,p

1) [kN] cracked concrete 6.7 10.7 1) The tensile design resistance is calculated from the tensile characteristic resistance No

Rk,p by NoRd,p= No

Rk,p/γMp, where the partial safety factor γMp is equal to 1.8 for M8 and 1.5 for M10.

N

c s

h

rec,c/s

(The Hilti CC-Method is a simplified Version of ETAG Annex C)

Page 28: Ancore Chimice Mecanice Pentru Sarcinimari

HSL-3 heavy duty anchor

60

NRd,c : Concrete cone resistance

N0Rd,c : Design concrete cone resistance

• Concrete compressive strength. fck.cube(150) = 25 N/mm2 Anchor size M8 M10 M12 M16 M20 M24 N0

Rd,c1) [kN] non-cracked concrete 15.6 19.7 24.1 33.6 46.9 61.7

N0Rd,c

1) [kN] cracked concrete 11.1 14.1 17.2 24.0 33.5 44.1

efh [mm] effective embedment depth 60 70 80 100 125 150 1) The tensile design resistance is calculated from the tensile characteristic resistance No

Rk,c by NoRd,c= No

Rk,c/γMc,N, where the partial safety factor γMc,N is equal to 1.5. fB: Influence of concrete strength

Concrete strength designation (ENV 206)

Cylinder compressive strength

fck,cyl [N/mm²]

Cube compressive strength

fck,cube [N/mm²]

fB

C20/25 20 25 1.0 C25/30 25 30 1.1 C30/37 30 37 1.22 C35/45 35 45 1.34 C40/50 40 50 1.41 C45/55 45 55 1.48 C50/60 50 60 1.55

Concrete cylinder: height 30cm, 15cm

diameter

Concrete cube: side length 15cm

Concrete test specimen geometry fAN: Influence of anchor spacing

Anchor spacing

Anchor size

s [mm] M8 M10 M12 M16 M20 M24 60 0.67 70 0.69 0.67 80 0.72 0.69 0.67 90 0.75 0.71 0.69

100 0.78 0.74 0.71 0.67 110 0.81 0.76 0.73 0.68 120 0.83 0.79 0.75 0.70 130 0.86 0.81 0.77 0.72 0.67 140 0.89 0.83 0.79 0.73 0.69 150 0.92 0.86 0.81 0.75 0.70 0.67 175 0.99 0.92 0.86 0.79 0.73 0.69 200 0.98 0.92 0.83 0.77 0.72 225 0.97 0.88 0.80 0.75 250 0.92 0.83 0.78 275 0.96 0.87 0.81 300 1.00 0.90 0.83 325 0.93 0.86 350 0.97 0.89 375 1.00 0.92 400 0.94 425 0.97 450 1.00

efAN h6

s5.0f⋅

+=

Limits:

N,crmin sss ≤≤

efhNcr,s 3 ⋅=

N,RN,ABo

c,Rdc,Rd fffNN ⋅⋅⋅=

25cubeck,f

Bf =

Limits: 25 N/mm2 ≤ fck,cube(150) ≤ 60 N/mm2

Page 29: Ancore Chimice Mecanice Pentru Sarcinimari

HSL-3 heavy duty anchor

60

efRN h

c5.025.0f ⋅+=

Limits: cmin ≤ c ≤ ccr,N ccr,N = 1.5hef

fRN: Influence of edge distance

Minimum thickness of concrete member, minimum spacing and minimum edge distance of anchors in cracked and uncracked concrete

Anchor size M8 M10 M12 M16 M20 M24

smin [mm] 60 70 80 100 125 150 Minimum spacing

for c ≥ [mm] 100 100 160 240 300 300

cmin [mm] 60 70 80 100 150 150 Minimum edge distance

for s ≥ [mm] 100 160 240 240 300 300

Minimum thickness hmin [mm] 120 140 160 200 250 300

Intermediate values by linear interpolation. NRd,s : Steel design tensile resistance Anchor size M8 M10 M12 M16 M20 M24 NRd,s

1) [kN] 19.5 30.9 44.9 83.7 130.7 188.3 1) The tensile design resistance is calculated from the tensile characteristic resistance NRd,s by NRd,s= NRk,s/γMs, where the partial safety factor γMs is 1.5. NRd : System design tensile resistance

NRd = lower of NRd,p , NRd,c and NRd,s Combined loading: Only if tensile load and shear load applied (See page 32 and section 4 “Examples”).

Detailed design method - Hilti CC

SHEAR The design shear resistance of a single anchor is the lower of,

VRd,c : concrete edge resistance VRd,s : steel resistance

Edge distance Anchor size c [mm] M8 M10 M12 M16 M20 M24

60 0.75 70 0.83 0.75 80 0.92 0.82 0.75 90 1.00 0.89 0.81 100 0.96 0.88 0.75 105 1.00 0.91 0.78 120 1.00 0.85 140 0.95 150 1.00 0.85 0.75 175 0.95 0.83 200 0.92 225 1.00

V

c srec,c/sc >1.5c

2

c >1.5c2

h>1.5c

(The Hilti CC-Method is a simplified Version of ETAG Annex C)

Note: If the conditions for h and c2 are not met, consult your Hilti technical advisory service.

Note: If more than 3 edges are smaller than ccr,N consult your Hilti Technical Advisory Service

Page 30: Ancore Chimice Mecanice Pentru Sarcinimari

HSL-3 heavy duty anchor

52

Features: - suitable for the tension zone - high loading capacity - force-controlled expansion - reliable pull-down of part fastened - no rotation in hole when tightening bolt Bolt Material:

- grade 8.8 acc. DIN EN ISO 898-1 galvanised to min. 5 microns

Versions: HSL-3 - bolt HSL-3-G - nut HSL-3-B - safety cap (automatic torque control) HSL-3-SK - countersunk head HSL-3-SH - socket head

Basic loading data (for a single anchor): HSL-3 / HSL-3-B / HSL-3-SH*/ HSL-3-SK* All data on this page applies to • concrete: as specified in the table • no edge distance and spacing influence • correct setting (See setting operations page 56) • steel failure

For detailed design method, see pages 57 – 61.

Mean ultimate resistance, Ru,m [kN]: concrete ≅ C20/25

Anchor size M8 M10 M12 M16 M20 M24 M8 M10 M12 M16 M20 M24 Tensile NRu,m

28.4 37.7 53.4 71.3 100.6 133.1 20.3 26.9 38.1 50.9 71.8 95.0 Shear VRu,m

43.0 63.5 88.9 128.6 160.6 239.7 43.0 63.5 88.9 128.6 160.6 239.7 Characteristic resistance, Rk [kN]: concrete ≅ C20/25

Anchor size M8 M10 M12 M16 M20 M24 M8 M10 M12 M16 M20 M24 Tensile NRk

23.4 29.5 36.1 50.4 70.4 92.6 16.7 21.1 25.8 36.0 50.3 66.1 Shear VRk

31.1 49.2 71.7 101.1 141.9 177.4 31.1 49.2 71.7 101.1 141.9 177.4 * HSL-3-SH, HSL-3-SK is only available up to M12

HSL-3

HSL-3-G

HSL-3-B

HSL-3-SK

HSL-3-SH

Concrete Tensile zone

Fire resistance

Hilti Anchor Programme

Close edge distance/ spacing

Fatigue Shock

cracked concrete non-cracked concrete

Page 31: Ancore Chimice Mecanice Pentru Sarcinimari

HSL-3 heavy duty anchor

53

Following values according to the:

Concrete Capacity Method Design resistance, Rd [kN]: concrete fck,cube = 25 N/mm2

Anchor size M8 M10 M12 M16 M20 M24 M8 M10 M12 M16 M20 M24 Tensile NRd

15.6 19.7 24.1 33.6 46.9 61.7 6.7 10.7 17.2 24.0 33.5 44.1 Shear VRd

24.9 39.4 57.4 80.9 113.5 141.9 24.9 39.4 57.4 80.9 113.5 141.9 Recommended load, Lrec [kN]: concrete fck,cube = 25 N/mm2

Anchor size M8 M10 M12 M16 M20 M24 M8 M10 M12 M16 M20 M24 Tensile NRec

11.1 14.0 17.2 24.0 33.5 44.1 4.8 7.6 12.3 17.1 24.0 31.5 Shear VRec

17.8 28.1 41.0 57.8 81.1 101.4 17.8 28.1 41.0 57.8 81.1 101.4 Basic loading data (for a single anchor): HSL-3 G All data on this section applies to • concrete: as specified in the table • no edge distance and spacing influence • correct setting (See setting operations page 56) • steel failure • For detailed design method, see pages 56 – 60.

Characteristic resistance, Rk [kN]: concrete ≅ C20/25

Anchor size M8 M10 M12 M16 M20 M8 M10 M12 M16 M20 Tensile NRk

23.4 29.5 36.1 50.4 70.4 16.7 21.1 25.8 36.0 50.3 Shear VRk

26.1 34.8 54.3 85.7 141.9 26.1 34.8 54.3 85.7 141.9 Following values according the:

Concrete Capacity Method Design resistance, Rd [kN]: concrete fck,cube= 25 N/mm2

Anchor size M8 M10 M12 M16 M20 M8 M10 M12 M16 M20 Tensile NRd

15.6 19.7 24.1 33.6 46.9 6.7 10.7 17.2 24.0 33.5 Shear VRd

20.9 27.8 43.4 68.6 113.5 20.9 27.8 43.4 68.6 113.5 Recommended load Lrec [kN]: fck,cube= 25 N/mm2

Anchor size M8 M10 M12 M16 M20 M8 M10 M12 M16 M20 Tensile NRec

11.1 14.0 17.2 24.0 33.5 4.8 7.6 12.3 17.1 24.0 Shear VRec

14.9 19.9 31.0 49.0 81.1 14.9 19.9 31.0 49.0 81.1 Installation equipment Rotary hammer (TE1, TE2, TE5, TE6, TE6A, TE15, TE15-C, TE18-M, TE35, TE55, TE76), hammer, torque wrench, blow out pump.

cracked concrete non-cracked concrete

Page 32: Ancore Chimice Mecanice Pentru Sarcinimari

HSL-3 heavy duty anchor

56

Setting details HSL-3

Anchor size M8/ tfix M10/ tfix M12/ tfix M16/ tfix M20/ tfix M24/ tfix

tfix [mm] Fastenable thickness (small/medium/large) 1) 5/20/40 5/20/40 5/25/50 10/25/50 10/30/60 10/30/60

d0 [mm] Nominal diameter of drill hole 12 15 18 24 28 32

[mm] Diameter of drill bit ≤ 12.5 ≤ 15.5 ≤ 18.5 ≤ 24.55 ≤ 28.55 ≤ 32.7 h1 [mm] Depth of drill hole 80 90 105 125 155 180

hef [mm] Effective anchorage depth 60 70 80 100 125 150

l [mm] Anchor length 2) tfix small tfix medium tfix large

83 98 118

95 110 130

111 131 156

138 153 178

163 183 213

185 205 235

[mm] Head height and washer 7.5 10 11 14 17 19

dw [mm] Washer diameter 20 25 30 40 45 50

hmin [mm] Min. base material thickness 120 140 160 200 250 300

df [mm] Clearance hole 14 17 20 26 31 35

SW [mm] Width across 13 17 19 24 30 36

Tinst [Nm] Torque moment 25 50 80 120 200 250

HSL-3-SH

Anchor size M8/ tfix M10/ tfix M12/ tfix

tfix [mm] Fastenable thickness 1) 5 20 25

d0 [mm] Nominal diameter of drill hole 12 15 18

[mm] Diameter of drill bit ≤ 12,5 ≤ 15,5 ≤ 18,5 h1 [mm] Depth of drill hole 85 95 110

hef [mm] Effective anchorage depth 60 70 80

l [mm] Anchor length 2) 88 120 142

[mm] Head height and washer 10 13 15

dw [mm] Washer diameter 20 25 30

hmin [mm] Min. base material thickness 120 140 160

df [mm] Clearance hole 14 17 20

SW [mm] Width across 6 8 10

Tinst [Nm] Torque moment 20 35 60

HSL-3-SK

Anchor size M8/ tfix M10/ tfix M12/ tfix

tfix [mm] Fastenable thickness (small/ /large) 1) 10/20 20 25

d0 [mm] Nominal diameter of drill hole 12 15 18

[mm] Diameter of drill bit ≤ 12,5 ≤ 15,5 ≤ 18,5 h1 [mm] Depth of drill hole 80 90 105

hef [mm] Effective anchorage depth 60 70 80

l [mm] Anchor length 2) 80/90 100 120

hmin [mm] Min. base material thickness 120 140 160

df [mm] Clearance hole 14 17 20

SW [mm] Size of hexagon socket screw key 6 8 10

Tinst [Nm] Torque moment 25 50 80

1) Other tfix possible 2) Other anchor length possible according to other tfix

1) Other tfix possible 2) Other anchor length possible according to other tfix

Page 33: Ancore Chimice Mecanice Pentru Sarcinimari

HSL-3 heavy duty anchor

56

HSL-3-G

Anchor size M8/ tfix M10/ tfix M12/ tfix M16/ tfix M20/ tfix

tfix [mm] Fastenable thickness (small/medium/large/ 100 mm) 1) 5/20/40/ 100

5/20/40/ 100

5/25/50/ 100

10/25/50/100

10/30/60/100

d0 [mm] Nominal diameter of drill hole 12 15 18 24 28 [mm] Diameter of drill bit ≤ 12,5 ≤ 15,5 ≤ 18,5 ≤ 24,55 ≤ 28,55

h1 [mm] Depth of drill hole 80 90 105 125 155

hef [mm] Effective anchorage depth 60 70 80 100 125

l [mm] Anchor length 2) tfix small tfix medium tfix large tfix = 100 mm

87 102 122 182

100 115 135 195

119 139 164 214

148 163 188 238

170 190 220 260

[mm] Head height and washer 8 11 13 17 20

dw [mm] Washer diameter 20 25 30 40 45

hmin [mm] Min. base material thickness 120 140 160 200 250 df [mm] Clearance hole (through setting) 14 17 20 26 31 df [mm] Clearance hole (only threaded rod carries the load) 9 12 14 18 22

SW [mm] Width across 13 17 19 24 30

Tinst [Nm] Torque moment 20 35 60 80 160

1) Other tfix possible 2) Other anchor length possible according to other tfix

Page 34: Ancore Chimice Mecanice Pentru Sarcinimari

HSL-3 heavy duty anchor

56

HSL-3-B

Anchor size M12/ tfix M16/ tfix M20/ tfix M24/ tfix

tfix [mm] ( small / medium / large) 1) 5/25/50 10/25/50 10/30/60 10/30/60

d0 [mm] Nominal diameter of drill hole 18 24 28 32

[mm] Diameter of drill bit ≤ 18.5 ≤ 24.55 ≤ 28.55 ≤ 32.7 h1 [mm] Depth of drill hole 105 125 155 180

hef [mm] Effective anchorage depth 80 100 125 150

l [mm] Anchor length 2) tfix small tfix medium tfix large

117 137 162

144 159 184

169 189 219

191 211 241

[mm] Head height and washer 16.5 19.5 22.5 24.5

dw [mm] Washer diameter 30 40 45 50

hmin [mm] Min. base material thickness 160 200 250 300

df [mm] Clearance hole 20 26 31 35

SW [mm] Width across 24 30 36 41

Tinst [Nm] Torque moment - - - -

1) Other tfix possible 2) Other anchor length possible according to other tfix

hmin h1

hef

Tinst.

tfix

Page 35: Ancore Chimice Mecanice Pentru Sarcinimari

HSL-3 heavy duty anchor

57

Setting operations

1

2

3

4

Drill hole. Blow out dust and fragments. Install anchor. Apply tightening torque (for HSL-3-B: no torque wrench is

needed) Anchor mechanical properties

Anchor size M8 M10 M12 M16 M20 M24

fuk [N/mm2] Nominal tensile strength 800 800 800 800 830 830

fyk [N/mm2] Yield strength 8.8 640 640 640 640 640 640

As [mm2] Stressed crossed-section 36.6 58.0 84.3 157.0 245.0 353.0

W [mm2] Elastic moment of resistance 30 60 105 266 519 898

Mrec [Nm] Recommended bending moment without sleeve 12.5 24.9 43.7 111.0 216.4 374.2

Detailed design method - Hilti CC

TENSION The tensile design resistance of a single anchor is the lower of,

NRd,p : concrete pull-out resistance NRd,c : concrete cone resistance NRd,s : steel resistance

NRd,p : Pull-out resistance Pull-out failure mode is only determinating for the anchor sizes M8 and M10 in cracked concrete

Bo

p,Rdp,Rd fNN ⋅= • Concrete compressive strength. fck.cube(150) = 25 N/mm2 Anchor size M8 M10

N0Rd,p

1) [kN] cracked concrete 6.7 10.7 1) The tensile design resistance is calculated from the tensile characteristic resistance No

Rk,p by NoRd,p= No

Rk,p/γMp, where the partial safety factor γMp is equal to 1.8 for M8 and 1.5 for M10.

N

c s

h

rec,c/s

(The Hilti CC-Method is a simplified Version of ETAG Annex C)

Page 36: Ancore Chimice Mecanice Pentru Sarcinimari

HSL-3 heavy duty anchor

60

NRd,c : Concrete cone resistance

N0Rd,c : Design concrete cone resistance

• Concrete compressive strength. fck.cube(150) = 25 N/mm2 Anchor size M8 M10 M12 M16 M20 M24 N0

Rd,c1) [kN] non-cracked concrete 15.6 19.7 24.1 33.6 46.9 61.7

N0Rd,c

1) [kN] cracked concrete 11.1 14.1 17.2 24.0 33.5 44.1

efh [mm] effective embedment depth 60 70 80 100 125 150 1) The tensile design resistance is calculated from the tensile characteristic resistance No

Rk,c by NoRd,c= No

Rk,c/γMc,N, where the partial safety factor γMc,N is equal to 1.5. fB: Influence of concrete strength

Concrete strength designation (ENV 206)

Cylinder compressive strength

fck,cyl [N/mm²]

Cube compressive strength

fck,cube [N/mm²]

fB

C20/25 20 25 1.0 C25/30 25 30 1.1 C30/37 30 37 1.22 C35/45 35 45 1.34 C40/50 40 50 1.41 C45/55 45 55 1.48 C50/60 50 60 1.55

Concrete cylinder: height 30cm, 15cm

diameter

Concrete cube: side length 15cm

Concrete test specimen geometry fAN: Influence of anchor spacing

Anchor spacing

Anchor size

s [mm] M8 M10 M12 M16 M20 M24 60 0.67 70 0.69 0.67 80 0.72 0.69 0.67 90 0.75 0.71 0.69

100 0.78 0.74 0.71 0.67 110 0.81 0.76 0.73 0.68 120 0.83 0.79 0.75 0.70 130 0.86 0.81 0.77 0.72 0.67 140 0.89 0.83 0.79 0.73 0.69 150 0.92 0.86 0.81 0.75 0.70 0.67 175 0.99 0.92 0.86 0.79 0.73 0.69 200 0.98 0.92 0.83 0.77 0.72 225 0.97 0.88 0.80 0.75 250 0.92 0.83 0.78 275 0.96 0.87 0.81 300 1.00 0.90 0.83 325 0.93 0.86 350 0.97 0.89 375 1.00 0.92 400 0.94 425 0.97 450 1.00

efAN h6

s5.0f⋅

+=

Limits:

N,crmin sss ≤≤

efhNcr,s 3 ⋅=

N,RN,ABo

c,Rdc,Rd fffNN ⋅⋅⋅=

25cubeck,f

Bf =

Limits: 25 N/mm2 ≤ fck,cube(150) ≤ 60 N/mm2

Page 37: Ancore Chimice Mecanice Pentru Sarcinimari

HSL-3 heavy duty anchor

60

efRN h

c5.025.0f ⋅+=

Limits: cmin ≤ c ≤ ccr,N ccr,N = 1.5hef

fRN: Influence of edge distance

Minimum thickness of concrete member, minimum spacing and minimum edge distance of anchors in cracked and uncracked concrete

Anchor size M8 M10 M12 M16 M20 M24

smin [mm] 60 70 80 100 125 150 Minimum spacing

for c ≥ [mm] 100 100 160 240 300 300

cmin [mm] 60 70 80 100 150 150 Minimum edge distance

for s ≥ [mm] 100 160 240 240 300 300

Minimum thickness hmin [mm] 120 140 160 200 250 300

Intermediate values by linear interpolation. NRd,s : Steel design tensile resistance Anchor size M8 M10 M12 M16 M20 M24 NRd,s

1) [kN] 19.5 30.9 44.9 83.7 130.7 188.3 1) The tensile design resistance is calculated from the tensile characteristic resistance NRd,s by NRd,s= NRk,s/γMs, where the partial safety factor γMs is 1.5. NRd : System design tensile resistance

NRd = lower of NRd,p , NRd,c and NRd,s Combined loading: Only if tensile load and shear load applied (See page 32 and section 4 “Examples”).

Detailed design method - Hilti CC

SHEAR The design shear resistance of a single anchor is the lower of,

VRd,c : concrete edge resistance VRd,s : steel resistance

Edge distance Anchor size c [mm] M8 M10 M12 M16 M20 M24

60 0.75 70 0.83 0.75 80 0.92 0.82 0.75 90 1.00 0.89 0.81 100 0.96 0.88 0.75 105 1.00 0.91 0.78 120 1.00 0.85 140 0.95 150 1.00 0.85 0.75 175 0.95 0.83 200 0.92 225 1.00

V

c srec,c/sc >1.5c

2

c >1.5c2

h>1.5c

(The Hilti CC-Method is a simplified Version of ETAG Annex C)

Note: If the conditions for h and c2 are not met, consult your Hilti technical advisory service.

Note: If more than 3 edges are smaller than ccr,N consult your Hilti Technical Advisory Service

Page 38: Ancore Chimice Mecanice Pentru Sarcinimari

HSL-3 heavy duty anchor

60

VRd,c : Concrete edge design resistance The lowest concrete edge resistance must be calculated. All nearby edges must be checked, (not only the edge in the direction of shear). Shear direction is accounted for by the factor fβ,V.

V,ARV,Bo

c,Rdc,Rd fffVV ⋅⋅⋅= β V0

Rd,c : Concrete edge design resistance • Concrete compressive strength fck,cube(150) = 25 N/mm2 • at a minimum edge distance minc Anchor size M8 M10 M12 M16 M20 M24 V0

Rd,c [kN] non-cracked concrete 4.7 6.5 8.6 13.7 27.5 29.7 V0

Rd,c [kN] cracked concrete 3.3 4.6 6.1 9.8 19.7 21.2 cmin [mm] min. edge distance 60 70 80 100 150 150 smin [mm] min. spacing distance 100 160 240 240 300 300 1) The shear design resistance is calculated from the shear characteristic resistance Vo

Rk,c by VoRd,c= Vo

Rk,c/γMc,V, where the partial safety factor γMc,V is equal to 1.5.

fB : Influence of concrete strength Concrete strength

designation (ENV 206)

Cylinder compressive strength

fck,cyl [N/mm²]

Cube compressive strength

fck,cube [N/mm²]

fB

C20/25 20 25 1.0 C25/30 25 30 1.1 C30/37 30 37 1.22 C35/45 35 45 1.34 C40/50 40 50 1.41 C45/55 45 55 1.48 C50/60 50 60 1.55

25f

f cube,ckB =

Limits: 25 N/mm2 ≤ fck,cube(150) ≤ 60 N/mm2

Concrete cylinder: height 30cm, 15cm

diameter

Concrete cube: side length 15cm

Concrete test specimen geometry

fβ,V : Influence of shear load direction

Angle β [°] fβ,V 0 to 55 1

60 1.1 70 1.2 80 1.5

90 to 180 2

Formulae: 1f V, =β

β+β=β sin5.0cos

1f V,

2f V, =β

for 0° ≤ β ≤ 55°

for 55° < β ≤ 90°

for 90° < β ≤ 180°

fAR.V : Influence of spacing and edge distance Formula for single anchor fastening influenced only by edge

minminV,AR c

cc

cf =

Formula for two-anchor fastening valid for s < 3c

minminV,AR c

cc6

sc3f +=

ccs

ss

2,2

12

3

n-1sc2,1

h >1,5 c

V ... applied shear force

β

results tabulated below

Page 39: Ancore Chimice Mecanice Pentru Sarcinimari

HSL-3 heavy duty anchor

61

General formula for n anchors (edge distance plus n-1 spacing) only valid where s1 to sn-1 are all < 3c and c2 > 1.5c

minmin

1n21V,AR c

cnc3

s...ssc3f ⋅++++

= −

Note : It is assumed that only the row of anchors closest to the free concrete edge carries the centric shear load

c/cmin fAR.V 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 3.2 3.4 3.6 3.8 4.0

Single anchor with edge influence 1.00 1.31 1.66 2.02 2.41 2.83 3.26 3.72 4.19 4.69 5.20 5.72 6.27 6.83 7.41 8.00

s/cmin 1.0 0.67 0.84 1.03 1.22 1.43 1.65 1.88 2.12 2.36 2.62 2.89 3.16 3.44 3.73 4.03 4.331.5 0.75 0.93 1.12 1.33 1.54 1.77 2.00 2.25 2.50 2.76 3.03 3.31 3.60 3.89 4.19 4.502.0 0.83 1.02 1.22 1.43 1.65 1.89 2.13 2.38 2.63 2.90 3.18 3.46 3.75 4.05 4.35 4.672.5 0.92 1.11 1.32 1.54 1.77 2.00 2.25 2.50 2.77 3.04 3.32 3.61 3.90 4.21 4.52 4.833.0 1.00 1.20 1.42 1.64 1.88 2.12 2.37 2.63 2.90 3.18 3.46 3.76 4.06 4.36 4.68 5.003.5 1.30 1.52 1.75 1.99 2.24 2.50 2.76 3.04 3.32 3.61 3.91 4.21 4.52 4.84 5.174.0 1.62 1.86 2.10 2.36 2.62 2.89 3.17 3.46 3.75 4.05 4.36 4.68 5.00 5.334.5 1.96 2.21 2.47 2.74 3.02 3.31 3.60 3.90 4.20 4.52 4.84 5.17 5.505.0 2.33 2.59 2.87 3.15 3.44 3.74 4.04 4.35 4.67 5.00 5.33 5.675.5 2.71 2.99 3.28 3.57 3.88 4.19 4.50 4.82 5.15 5.49 5.836.0 2.83 3.11 3.41 3.71 4.02 4.33 4.65 4.98 5.31 5.65 6.006.5 3.24 3.54 3.84 4.16 4.47 4.80 5.13 5.47 5.82 6.177.0 3.67 3.98 4.29 4.62 4.95 5.29 5.63 5.98 6.337.5 4.11 4.43 4.76 5.10 5.44 5.79 6.14 6.508.0 4.57 4.91 5.25 5.59 5.95 6.30 6.678.5 5.05 5.40 5.75 6.10 6.47 6.839.0 5.20 5.55 5.90 6.26 6.63 7.009.5 5.69 6.05 6.42 6.79 7.1710.0 6.21 6.58 6.95 7.3310.5 6.74 7.12 7.5011.0 7.28 7.6711.5 7.83

12.0 8.00 VRd,s : Steel design shear resistance Anchor size M8 M10 M12 M16 M20 M24

HSL-3 24.9 39.4 57.4 80.9 113.5 141.9

HSL-3-SH, HSL-3-SK 24.9 39.4 57.4 - - -

HSL-3-G 20.9 27.8 43.4 68.6 113.5 - VRd,s [kN]

HSL-3-G threaded rod only 11.7 18.6 27.0 50.2 78.4 - The shear design resistance is calculated from the shear characteristic resistance VRd,s by VRd,s= VRk,s/γMs, where the partial safety factor γMs is 1.25. VRd : System design shear resistance

VRd : System design shear resistance

VRd = lower of VRd,c and VRd,s Combined loading: Only if tensile load and shear load applied (See page 32 and section 4 “Examples”).

These results are for a two-. Anchor fastening. For fastening made with more than 2 anchors, use the general formulae for n anchors at the top of the page.

Page 40: Ancore Chimice Mecanice Pentru Sarcinimari

HSL-3 Heavy Duty Sleeve Anchor 4.3.2

Mechanical Anchoring Systems

• • • • • • • • •

HSL-3 Heavy Duty Anchor HSL-3-B Heavy Duty Anchor with Torque Cap HSL-3-G Heavy Duty Anchor with Threaded Rod Metric Maximum fastened thickness (mm)

HSL-3-G M 12/25 Heavy duty blank-bolt Metric thread size (mm); Sleeve (Expansion) G: stud not hole diameter Anchor B: torque cap 4.3.2.1 Product Description The Hilti HSL-3 Heavy Duty Sleeve Anchor is a torque-controlled expansion bolt designed for high performance in static and dynamic application including the tension zone of concrete structures where cracking can be expected. HSL-3 anchors are available in metric sizes from M8 (5/16”) to M24 (1”). With a variety of head styles, including bolt, stud and torque cap. All versions are available in zinc-plated carbon steel. Product Features

Approved for use in the concrete tension zone (cracked concrete) Data for use with the Strength design provisions of ACI 318-02 Appendix D and ACI 349-01 Appendix B Allowable stress design data for use with ASD methods High load capacity Force-controlled expansion (allows for follow-up expansion) Reliable pull-down of part fastened to overcome gaps Suitable for dynamic loading, including seismic, fatigue and shock No spinning of the anchor in hole when tightening bolt or nut Seismic qualification per ICC-ES AC193 and the requirements of ACI 318-02 Appendix D

Guide Specification Expansion Anchors: Carbon steel anchor consists of hex bolt (threaded stud), sleeve, expansion sleeve, expansion cone, collapsible plastic sleeve, (nut) and washer. Anchors shall be torque controlled expansion bolt as manufactured by Hilti, Inc., Tulsa, OK. 4.3.2.2 Material Specifications Carbon Steel Bolt or Threaded Rod for HSL-3 (Bolt), HSL-3 (Stud) and HSL-3-B conform to DIN EN ISO 898-1, Grade 8.8, fy > 93 ksi Carbon Steel Nut conforms to DIN 934, Grade 8, fu > 116 ksi Carbon Steel Washer conforms to DIN 1544, Grade St37, fu > 100 ksi Carbon Steel Expansion Cone conforms to DIN 1654-4, fu > 80 ksi Carbon Steel Expansion Sleeve conforms to DIN 1624 Carbon Steel Spacing Sleeve conforms to DIN 2393 T1, fu > 100 ksi Collapsible Sleeve is made from acetal polyoxymethylene (POM) resin

Plastic collapsible section with anchor rotation prevention

Expansion Sleeve

Cone

Spacer Sleeve

Minimum Embedment Mark

Bolt Washer

Three accurately sized shear pins are provided in the red indicator cap. On applying the required torque with an ordinary wrench, the red indicator cap shears off. The green seal on the bolt head which appears indicates that the anchor has been properly set

4.3.2 HSL-34.3.2.1 Product Description 4.3.2.2 Material Specification 4.3.2.3 Technical Data 4.3.2.4 Edge and Spacing Distance Guidelines for ASD Data 4.3.2.5 Installation Instructions 4.3.2.6 Ordering Information

Example: HSL-3-G M12/25This is an HSL-3 stud anchor. The thread size is 12 mm and this anchor can attach up to a 25 mm thick plate

Red Setting Indicator

Listings/Approvals • International Code Council Evaluation Services (ICC ES), ESR-Pending • European Technical Approval, ETA-02/0042

1

Page 41: Ancore Chimice Mecanice Pentru Sarcinimari

HSL-3 Heavy Duty Sleeve Anchor 4.3.2

Mechanical Anchoring Systems

• • • • • • • • •

HSL-3 Heavy Duty Anchor HSL-3-B Heavy Duty Anchor with Torque Cap HSL-3-G Heavy Duty Anchor with Threaded Rod Metric Maximum fastened thickness (mm)

HSL-3-G M 12/25 Heavy duty blank-bolt Metric thread size (mm); Sleeve (Expansion) G: stud not hole diameter Anchor B: torque cap 4.3.2.1 Product Description The Hilti HSL-3 Heavy Duty Sleeve Anchor is a torque-controlled expansion bolt designed for high performance in static and dynamic application including the tension zone of concrete structures where cracking can be expected. HSL-3 anchors are available in metric sizes from M8 (5/16”) to M24 (1”). With a variety of head styles, including bolt, stud and torque cap. All versions are available in zinc-plated carbon steel. Product Features

Approved for use in the concrete tension zone (cracked concrete) Data for use with the Strength design provisions of ACI 318-02 Appendix D and ACI 349-01 Appendix B Allowable stress design data for use with ASD methods High load capacity Force-controlled expansion (allows for follow-up expansion) Reliable pull-down of part fastened to overcome gaps Suitable for dynamic loading, including seismic, fatigue and shock No spinning of the anchor in hole when tightening bolt or nut Seismic qualification per ICC-ES AC193 and the requirements of ACI 318-02 Appendix D

Guide Specification Expansion Anchors: Carbon steel anchor consists of hex bolt (threaded stud), sleeve, expansion sleeve, expansion cone, collapsible plastic sleeve, (nut) and washer. Anchors shall be torque controlled expansion bolt as manufactured by Hilti, Inc., Tulsa, OK. 4.3.2.2 Material Specifications Carbon Steel Bolt or Threaded Rod for HSL-3 (Bolt), HSL-3 (Stud) and HSL-3-B conform to DIN EN ISO 898-1, Grade 8.8, fy > 93 ksi Carbon Steel Nut conforms to DIN 934, Grade 8, fu > 116 ksi Carbon Steel Washer conforms to DIN 1544, Grade St37, fu > 100 ksi Carbon Steel Expansion Cone conforms to DIN 1654-4, fu > 80 ksi Carbon Steel Expansion Sleeve conforms to DIN 1624 Carbon Steel Spacing Sleeve conforms to DIN 2393 T1, fu > 100 ksi Collapsible Sleeve is made from acetal polyoxymethylene (POM) resin

Plastic collapsible section with anchor rotation prevention

Expansion Sleeve

Cone

Spacer Sleeve

Minimum Embedment Mark

Bolt Washer

Three accurately sized shear pins are provided in the red indicator cap. On applying the required torque with an ordinary wrench, the red indicator cap shears off. The green seal on the bolt head which appears indicates that the anchor has been properly set

4.3.2 HSL-34.3.2.1 Product Description 4.3.2.2 Material Specification 4.3.2.3 Technical Data 4.3.2.4 Edge and Spacing Distance Guidelines for ASD Data 4.3.2.5 Installation Instructions 4.3.2.6 Ordering Information

Example: HSL-3-G M12/25This is an HSL-3 stud anchor. The thread size is 12 mm and this anchor can attach up to a 25 mm thick plate

Red Setting Indicator

Listings/Approvals • International Code Council Evaluation Services (ICC ES), ESR-Pending • European Technical Approval, ETA-02/0042

1

Page 42: Ancore Chimice Mecanice Pentru Sarcinimari

HSL-3 Heavy Duty Sleeve Anchor 4.3.2

Mechanical Anchoring Systems 4.3.2.3 Technical Data HSL-3 Specification Table

HSL-3 Anchor Thread Diameter (mm) Details

M8 M10 M12 M16 M20 M24 nominal drill bit diameter1 dbit mm 12 15 18 24 28 32 Hilti matched-tolerance carbide-tipped drill bit - -

TE-CX 12/22 TE-YX 12/35

TE-CX 15/27 TE-YX 15/35

TE-C 18/22 TE-YX 18/32

TE-C-T 24/27 TE-YX 24/32

TE-C-T 28/27 TE-YX 28/32

TE-YX 32/37

mm 110 (120) 120 (140) 135 (160) 160 (200) 190 (250) 225 (300) minimum base material thickness (to obtain smallest critical edge distance) h

(in.) 4 3/8 (4 3/4) 4 3/4 (5 1/2) 5 3/8 (6 1/4) 6 1/4 (7 7/8) 7 1/2 (9 7/8) 8 7/8 (11 7/8) mm 80 90 105 125 155 180 minimum hole depth ho (in.) (3 1/8) (3 1/2) (4 1/8) (4 7/8) (6 1/8) (7 1/8) mm 60 70 80 100 125 150 effective embedment depth hef (in.) (2 3/8) (2 3/4) (3 1/8) (3 7/8) (4 7/8) (5 7/8) mm 14-15 17-18 20-21 26-28 31-33 35-37 minimum clearance hole diameter in

part being fastened dh (in.) (1/2) (5/8) (3/4) (1) (1 1/4) (1 3/8) mm 4 5 8 9 12 16 max. cumulative gap between part(s)

being fastened and concrete surface - (in.) (1/8) (3/16) (5/16) (3/8) (1/2) (5/8) mm 20 40 20 40 25 50 25 50 30 60 30 60 maximum thickness of part fastened

HSL-3, HSL-3-B t (in.) (3/4) (1 ½) (3/4) (1 ½) (1) (2) (1) (2) (1 1/8) (2 1/4) (1 1/8) (2 1/4) mm 98 118 110 130 131 156 153 178 183 213 205 235 overall length of anchor

HSL-3, HSL-3-B ℓ (in.) (3 7/8) (4 5/8) (4 3/8) (5 1/8 (5 1/8) (6 1/8) (6) (7) (7 1/4) (8 3/8) (8) (9 1/4) mm 20 40 25 50 25 50 30 60 maximum thickness of part fastened

HSL-3-G t (in.) (3/4) (1 ½) (1) (2) (1) (2) (1 1/8) (2 1/4)

mm 102 115 139 164 163 188 190 220 overall length of anchor HSL-3-G ℓ

(in.) (4) (4 ½) (5 1/2) (6 3/8) (6 3/8) (7 3/8) (7 1/2) (8 3/4)

mm 20 25 30 40 45 50 washer diameter dw (in.) (3/4) (1) (1 1/8) (1 9/16) (1 3/4) (2)

Nm 25 50 80 120 200 250 installation torque HSL-3 Tinst (ft-lb) (18) (37) (59) (89) (148) (185) Nm 20 35 60 80 160 installation torque HSL-3-G Tinst (ft-lb) (15) (26) (44) (59) (118)

wrench size HSL-3, HSL-3-G - mm 13 17 19 24 30 36 wrench size HSL-3-B - mm 24 30 36 41

For pound-inch units: 1 mm = 0.03937 inches, 1 Nm = 0.735 ft-lbf 1Use metric bits only.

2

Page 43: Ancore Chimice Mecanice Pentru Sarcinimari

HSL-3 Heavy Duty Sleeve Anchor 4.3.2

Mechanical Anchoring Systems 4.3.2.3 Technical Data HSL-3 Specification Table

HSL-3 Anchor Thread Diameter (mm) Details

M8 M10 M12 M16 M20 M24 nominal drill bit diameter1 dbit mm 12 15 18 24 28 32 Hilti matched-tolerance carbide-tipped drill bit - -

TE-CX 12/22 TE-YX 12/35

TE-CX 15/27 TE-YX 15/35

TE-C 18/22 TE-YX 18/32

TE-C-T 24/27 TE-YX 24/32

TE-C-T 28/27 TE-YX 28/32

TE-YX 32/37

mm 110 (120) 120 (140) 135 (160) 160 (200) 190 (250) 225 (300) minimum base material thickness (to obtain smallest critical edge distance) h

(in.) 4 3/8 (4 3/4) 4 3/4 (5 1/2) 5 3/8 (6 1/4) 6 1/4 (7 7/8) 7 1/2 (9 7/8) 8 7/8 (11 7/8) mm 80 90 105 125 155 180 minimum hole depth ho (in.) (3 1/8) (3 1/2) (4 1/8) (4 7/8) (6 1/8) (7 1/8) mm 60 70 80 100 125 150 effective embedment depth hef (in.) (2 3/8) (2 3/4) (3 1/8) (3 7/8) (4 7/8) (5 7/8) mm 14-15 17-18 20-21 26-28 31-33 35-37 minimum clearance hole diameter in

part being fastened dh (in.) (1/2) (5/8) (3/4) (1) (1 1/4) (1 3/8) mm 4 5 8 9 12 16 max. cumulative gap between part(s)

being fastened and concrete surface - (in.) (1/8) (3/16) (5/16) (3/8) (1/2) (5/8) mm 20 40 20 40 25 50 25 50 30 60 30 60 maximum thickness of part fastened

HSL-3, HSL-3-B t (in.) (3/4) (1 ½) (3/4) (1 ½) (1) (2) (1) (2) (1 1/8) (2 1/4) (1 1/8) (2 1/4) mm 98 118 110 130 131 156 153 178 183 213 205 235 overall length of anchor

HSL-3, HSL-3-B ℓ (in.) (3 7/8) (4 5/8) (4 3/8) (5 1/8 (5 1/8) (6 1/8) (6) (7) (7 1/4) (8 3/8) (8) (9 1/4) mm 20 40 25 50 25 50 30 60 maximum thickness of part fastened

HSL-3-G t (in.) (3/4) (1 ½) (1) (2) (1) (2) (1 1/8) (2 1/4)

mm 102 115 139 164 163 188 190 220 overall length of anchor HSL-3-G ℓ

(in.) (4) (4 ½) (5 1/2) (6 3/8) (6 3/8) (7 3/8) (7 1/2) (8 3/4)

mm 20 25 30 40 45 50 washer diameter dw (in.) (3/4) (1) (1 1/8) (1 9/16) (1 3/4) (2)

Nm 25 50 80 120 200 250 installation torque HSL-3 Tinst (ft-lb) (18) (37) (59) (89) (148) (185) Nm 20 35 60 80 160 installation torque HSL-3-G Tinst (ft-lb) (15) (26) (44) (59) (118)

wrench size HSL-3, HSL-3-G - mm 13 17 19 24 30 36 wrench size HSL-3-B - mm 24 30 36 41

For pound-inch units: 1 mm = 0.03937 inches, 1 Nm = 0.735 ft-lbf 1Use metric bits only.

2

Page 44: Ancore Chimice Mecanice Pentru Sarcinimari

HSL-3 Heavy Duty Sleeve Anchor 4.3.2

Mechanical Anchoring Systems Allowable Stress Design Static Tension Loads for Uncracked Normal Weight Concrete1,3

Concrete Compressive Strength2

13.8 MPa (2,000 psi)

20.7 MPa (3,000 psi)

27.6 MPa (4,000 psi)

41.4 MPa (6,000 psi) Anchor

Diameter

Embedment Depth

hef mm (in.)

Condition A

kN (lb)

Condition B

kN (lb)

Condition A

kN (lb)

Condition B

kN (lb)

Condition A

kN (lb)

Condition B

kN (lb)

Condition A

kN (lb)

Condition B

kN (lb)

7.8 7.8 9.5 9.5 11.0 11.0 13.5 13.5 M8 60

(2 3/8) (1,746) (1,746) (2,139) (2,139) (2,470) (2,470) (3,025) (3,025) 11.7 10.1 14.3 12.4 12.1 14.3 20.3 17.6

M10 70 (2 3/4) (2,631) (2,280) (3,222) (2,792) (3,720) (3,224) (4,556) (3,949)

14.3 12.4 17.5 15.2 20.2 17.5 24.8 21.6 M12 80

(3 1/8) (3,214) (2,785) (3,936) (3,411) (4,545) (3,939) (5,567) (4,825) 20.0 17.3 24.5 21.2 28.3 24.5 34.6 30.0

M16 100 (3 15/16) (4,492) (3,893) (5,501) (4,768) (6,352) (5,505) (7,780) (6,743)

27.9 24.2 34.2 29.6 39.5 34.2 48.4 41.9 M20 125

(4 15/16) (6,277) (5,440) (7,688) (6,663) (8,877) (7,694) (10,873) (9,423) 36.7 31.8 50.0 39.0 51.9 45.0 63.6 55.1

M24 150 (5 15/16) (8,252) (7,152) (10,106) (8,759) (11,670) (10,114) (14,292) (12,387)

For SI: 1 lbf = 4.45 N, 1 psi = 0.00689 MPa For pound-inch units: 1 mm = 0.03937 inches 1Values are for single anchors with no edge distance or spacing reduction. 2Values are for normal weight concrete. For sand-lightweight concrete, multiply values by 0.85. For all-lightweight concrete, multiply values by 0.75. See ACI 318-02 Section D.3.4. 3 Condition A applies where the potential concrete failure surfaces are crossed by supplementary reinforcement proportioned to tie the potential concrete failure prism into the structural member. Condition B applies where such supplementary reinforcement is not provided, or where pullout or pryout strength governs. See ACI 318-02 Appendix D section D.4.4

Allowable Stress Design Static Shear loads for Uncracked Concrete1

Allowable Steel Capacity, Shear Anchor

Diameter HSL-3, HSL-3-B kN (lb)

HSL-3-G kN (lb)

M8 15.0 (3,361)

12.5 (2,818)

M10 21.1 (4,749)

17.3 (3,893)

M12 29.1 (6,837)

25.1 (5,647)

M16 55.2 (12,400)

46.8 (10,531)

M20 81.6 (18,349)

68.5 (15,395)

M24 94.9 (21,334)

For SI: 1 lbf = 4.45 N 1Values are for single anchors with no edge distance or spacing reduction due to concrete failure.

3

Page 45: Ancore Chimice Mecanice Pentru Sarcinimari

HSL-3 Heavy Duty Sleeve Anchor 4.3.2

Mechanical Anchoring Systems

4.3.2.4 Edge and Spacing Distance Guidelines for ASD Data

Anchor Size hef mm (in.) M8 60 (2 3/8) M10 70 (2 ¾) M12 80 (3 1/8) M16 100 (3 15/16) M20 125 (4 15/16) M24 150 (5 15/16)

c = actual edge distance s = actual spacing h = slab thickness

M8 M10 M12 M16 M20 M2460 (2 3/8) 0.6970 (2 3/4) 0.72 0.6779 (3 1/8) 0.75 0.69 0.6789 (3 1/2) 0.77 0.71 0.68102 (4) 0.81 0.74 0.71 0.67127 (5) 0.88 0.80 0.75 0.71 0.67152 (6) 0.95 0.86 0.81 0.75 0.70 0.67171 (6 3/4) 1.00 0.91 0.86 0.79 0.73 0.69178 (7) 0.92 0.87 0.80 0.74 0.69203 (8) 0.98 0.91 0.84 0.77 0.72213 (8 3/8) 1.00 0.93 0.86 0.78 0.74229 (9) 0.96 0.88 0.80 0.75254 (10) 1.00 0.92 0.84 0.78279 (11) 0.96 0.87 0.81305 (12) 1.00 0.91 0.84330 (13) 0.94 0.87381 (15) 1.00 0.92457 (18) 1.00

Tension Load Adjustmant Factors for Anchor Spacing fA

Anchor DiameterSpacing s

mm (in.)

M8 M10 M12 M16 M20 M2460 (2 3/8) 0.6370 (2 3/4) 0.69 0.7183 (3 1/4) 0.78 0.7989 (3 1/2) 0.83 0.83 0.80

102 (4) 0.95 0.92 0.88108 (4 1/4) 1.00 0.97 0.92111 (4 3/8) 1.00 0.94121 (4 3/4) 1.00 0.85127 (5) 0.88 0.63140 (5 1/2) 0.95 0.67149 (5 7/8) 1.00 0.70 0.75165 (6 1/2) 0.75 0.80178 (7) 0.80 0.84191 (7 1/2) 0.84 0.88203 (8) 0.90 0.92225 (8 7/8) 1.00 1.00

Anchor Diameter

Tension Load Adjustment Factors for Edge Distance fRDistance

c mm (in.)

Notes: Tension reduction factors are based on a minimum base material thickness of 2 x hef Shear reduction factors are based on a thick base material at the edge (i.e. no influence from a thin base material)

4

Page 46: Ancore Chimice Mecanice Pentru Sarcinimari

HSL-3 Heavy Duty Sleeve Anchor 4.3.2

Mechanical Anchoring Systems Edge Distance Guidelines for Shear Loading by Concrete Compressive Strength- Part 1

M8 M10 M12 M16 M20 M24 M8 M10 M12 M16 M20 M8 M10 M12 M16 M20 M24 M8 M10 M12 M16 M2060 (2 3/8) 0.13 0.16 0.16 0.2070 (2 3/4) 0.17 0.13 0.20 0.16 0.20 0.16 0.24 0.2089 (3 1/2) 0.24 0.19 0.15 0.29 0.23 0.18 0.29 0.23 0.18 0.35 0.28 0.22102 (4) 0.29 0.23 0.18 0.35 0.28 0.21 0.36 0.28 0.22 0.43 0.35 0.26111 (4 3/8) 0.34 0.27 0.20 0.40 0.32 0.25 0.41 0.33 0.25 0.49 0.40 0.30121 (4 3/4) 0.38 0.30 0.23 0.15 0.45 0.37 0.28 0.17 0.47 0.37 0.28 0.18 0.55 0.45 0.34 0.21127 (5) 0.41 0.33 0.25 0.16 0.11 0.49 0.40 0.30 0.19 0.14 0.50 0.40 0.30 0.19 0.14 0.60 0.49 0.37 0.23 0.17149 (5 7/8) 0.52 0.41 0.32 0.20 0.15 0.13 0.62 0.51 0.38 0.24 0.17 0.64 0.51 0.39 0.25 0.18 0.16 0.76 0.62 0.47 0.29 0.21165 (6 1/2) 0.61 0.48 0.37 0.23 0.17 0.16 0.72 0.59 0.44 0.27 0.20 0.74 0.59 0.45 0.29 0.21 0.19 0.89 0.72 0.54 0.34 0.25178 (7) 0.68 0.54 0.41 0.26 0.19 0.18 0.81 0.66 0.50 0.31 0.23 0.83 0.66 0.50 0.32 0.23 0.21 1.00 0.80 0.61 0.38 0.28191 (7 1/2) 0.75 0.60 0.46 0.29 0.21 0.19 0.90 0.73 0.55 0.34 0.25 0.92 0.73 0.56 0.35 0.26 0.24 0.89 0.67 0.42 0.31203 (8) 0.83 0.66 0.50 0.32 0.23 0.21 1.00 0.80 0.61 0.37 0.28 1.00 0.81 0.61 0.39 0.28 0.26 1.00 0.74 0.46 0.34225 (8 7/8) 0.97 0.77 0.59 0.37 0.27 0.25 0.94 0.71 0.44 0.32 0.94 0.72 0.46 0.33 0.31 0.87 0.54 0.40229 (9) 1.00 0.79 0.60 0.38 0.28 0.26 0.96 0.72 0.45 0.33 0.96 0.73 0.46 0.34 0.31 0.89 0.55 0.41235 (9 1/4) 0.82 0.62 0.40 0.29 0.27 1.00 0.75 0.47 0.34 1.00 0.76 0.48 0.35 0.33 0.92 0.57 0.42248 (9 3/4) 0.89 0.67 0.43 0.31 0.29 0.82 0.50 0.37 0.83 0.52 0.38 0.35 1.00 0.62 0.46254 (10) 0.92 0.70 0.44 0.32 0.30 0.85 0.52 0.39 0.86 0.54 0.40 0.37 0.64 0.47267 (10 1/2) 1.00 0.76 0.49 0.35 0.33 0.93 0.57 0.42 0.94 0.59 0.43 0.40 0.70 0.55279 (11) 0.81 0.51 0.37 0.35 0.98 0.60 0.45 1.00 0.63 0.46 0.42 0.74 0.56286 (11 1/4) 0.84 0.53 0.39 0.36 1.00 0.62 0.46 0.65 0.47 0.44 0.76 0.57305 (12) 0.92 0.58 0.43 0.39 0.69 0.51 0.72 0.52 0.48 0.84 0.62324 (12 3/4) 1.00 0.64 0.47 0.43 0.75 0.56 0.78 0.57 0.53 0.92 0.68330 (13) 0.66 0.48 0.44 0.78 0.57 0.81 0.59 0.54 0.95 0.70343 (13 1/2) 0.70 0.51 0.47 0.78 0.57 0.85 0.62 0.57 1.00 0.74356 (14) 0.74 0.54 0.50 0.87 0.64 0.90 0.66 0.61 0.79381 (15) 0.82 0.60 0.55 0.96 0.71 1.00 0.73 0.67 0.87391 (15 3/8) 0.85 0.62 0.57 1.00 0.74 0.76 0.70 0.91406 (16) 0.90 0.66 0.61 0.78 0.81 0.74 0.96419 (16 1/2) 0.94 0.69 0.63 0.82 0.84 0.78 1.00438 (17 1/4) 1.00 0.74 0.68 0.88 0.90 0.83457 (18) 0.78 0.72 0.94 0.96 0.88470 (18 1/2) 0.82 0.75 0.97 1.00 0.92483 (19) 0.85 0.78 1.00 0.96495 (19 1/2) 0.88 0.81 1.00508 (20) 0.92 0.85533 (21) 1.00 0.91559 (22) 0.98565 (22 1/4) 1.00

Anchor Diameter Anchor Diameter Anchor DiameterAnchor DiameterHSL-3, HSL-3-B HSL-3-G HSL-3, HSL-3-B HSL-3-G

Load Adjustment Factors, fR, for Shear Loading Toward the Edge (single anchor)13.8 MPa (2,000 psi) 20.7 MPa (3,000 psi)

Edge Distance c

mm (in.)

1 Does not include effects of thin base materials at the edge.

5

Page 47: Ancore Chimice Mecanice Pentru Sarcinimari

HSL-3 Heavy Duty Sleeve Anchor 4.3.2

Mechanical Anchoring Systems Edge Distance Guidelines for Shear Loading by Concrete Compressive Strength – Part 2

M8 M10 M12 M16 M20 M24 M8 M10 M12 M16 M20 M8 M10 M12 M16 M20 M24 M8 M10 M12 M16 M2060 (2 3/8) 0.19 0.23 0.23 0.2870 (2 3/4) 0.24 0.19 0.28 0.23 0.29 0.23 0.35 0.2889 (3 1/2) 0.34 0.27 0.21 0.41 0.33 0.25 0.42 0.33 0.25 0.50 0.40 0.30102 (4) 0.41 0.33 0.25 0.49 0.40 0.30 0.51 0.40 0.31 0.61 0.49 0.37111 (4 3/8) 0.47 0.38 0.29 0.57 0.46 0.35 0.58 0.46 0.35 0.69 0.56 0.43121 (4 3/4) 0.54 0.43 0.32 0.21 0.64 0.52 0.39 0.24 0.66 0.52 0.40 0.25 0.78 0.64 0.48 0.30127 (5) 0.58 0.46 0.35 0.22 0.16 0.69 0.56 0.42 0.26 0.19 0.71 0.56 0.43 0.27 0.20 0.85 0.69 0.52 0.32 0.24140 (5 1/2) 0.69 0.54 0.42 0.26 0.19 0.82 0.66 0.50 0.31 0.23 0.84 0.67 0.51 0.32 0.24 1.00 0.81 0.62 0.38 0.28149 (5 7/8) 0.74 0.59 0.45 0.28 0.21 0.19 0.88 0.71 0.54 0.33 0.25 0.90 0.72 0.55 0.35 0.25 0.23 0.87 0.66 0.41 0.30159 (6 1/4) 0.82 0.65 0.50 0.31 0.23 0.21 0.98 0.79 0.60 0.37 0.27 1.00 0.80 0.61 0.39 0.28 0.26 0.97 0.73 0.45 0.34162 (6 3/8) 0.84 0.67 0.51 0.32 0.24 0.22 1.00 0.81 0.61 0.38 0.28 0.82 0.62 0.39 0.29 0.27 1.00 0.75 0.46 0.34165 (6 1/2) 0.86 0.68 0.52 0.33 0.24 0.22 0.83 0.63 0.39 0.29 0.83 0.64 0.40 0.29 0.27 0.77 0.48 0.35178 (7) 0.96 0.76 0.58 0.37 0.27 0.25 0.93 0.70 0.43 0.32 0.93 0.71 0.45 0.33 0.30 0.86 0.53 0.39181 (7 1/8) 1.00 0.79 0.61 0.38 0.28 0.26 0.97 0.73 0.45 0.33 0.97 0.74 0.47 0.34 0.32 0.90 0.55 0.41187 (7 3/8) 0.82 0.62 0.40 0.29 0.27 1.00 0.76 0.47 0.35 1.00 0.76 0.49 0.35 0.33 0.93 0.57 0.42191 (7 1/2) 0.84 0.64 0.41 0.30 0.27 0.78 0.48 0.36 0.79 0.50 0.37 0.34 0.95 0.59 0.44197 (7 3/4) 0.89 0.68 0.43 0.31 0.29 0.82 0.51 0.37 0.83 0.53 0.38 0.35 1.00 0.62 0.46203 (8) 0.93 0.71 0.45 0.33 0.30 0.86 0.53 0.39 0.87 0.55 0.40 0.37 0.65 0.48216 (8 1/2) 1.00 0.78 0.49 0.36 0.33 0.94 0.58 0.43 0.95 0.60 0.44 0.41 0.71 0.53225 (8 7/8) 0.83 0.53 0.38 0.35 1.00 0.62 0.46 1.00 0.64 0.47 0.43 0.76 0.56254 (10) 1.00 0.63 0.46 0.42 0.74 0.55 0.77 0.56 0.52 0.91 0.67270 (10 5/8) 0.70 0.51 0.47 0.82 0.61 0.85 0.62 0.57 1.00 0.74279 (11) 0.73 0.53 0.49 0.85 0.63 0.89 0.65 0.60 0.77305 (12) 0.83 0.60 0.56 0.97 0.72 1.00 0.74 0.68 0.88311 (12 1/4) 0.85 0.62 0.57 1.00 0.74 0.76 0.70 0.91318 (12 1/2) 0.88 0.64 0.59 0.77 0.79 0.72 0.94330 (13) 0.93 0.68 0.63 0.81 0.83 0.77 1.00343 (13 1/2) 1.00 0.73 0.67 0.87 0.89 0.77356 (14) 0.76 0.70 0.91 0.93 0.86371 (14 5/8) 0.82 0.75 0.98 1.00 0.92381 (15) 0.84 0.78 1.00 0.95394 (15 1/2) 0.89 0.82 1.00406 (16) 0.93 0.86425 (16 3/4) 1.00 0.92448 (17 5/8) 1.00

Anchor Diameter Anchor Diameter Anchor Diameter Anchor DiameterHSL-3, HSL-3-B HSL-3G HSL-3, HSL-3-B

27.6 MPa (4,000 psi) 41.4 MPa (6,000 psi)Load Adjustment Factors, fR, for Shear Loading Toward the Edge (single anchor)

Edge Distance c

mm (in.)

HSL-3G

1 Does not include effects of thin base materials at the edge.

6

Page 48: Ancore Chimice Mecanice Pentru Sarcinimari

HSL-3 Heavy Duty Sleeve Anchor 4.3.2

Mechanical Anchoring Systems

7

4.3.2.5 Installation Instructions .

Step 3:

Using a hammer, tap the anchor through

the part being fastened into the drilled hole

until the washer is in contact with the

fastened part. Do not expand anchor by

hand prior to installation.

Step 2:

Remove drilling debris with a

blowout bulb or with

compressed air.

Step 1:

Using the correct diameter

metric bit, drill hole to minimum

required hole depth or deeper.

Step 4:

Using a torque wrench, apply the

specified installation torque. HSL-3-

B does not require use of a torque

wrench.

4.3.2.6 Ordering Information

HSL-3 Bolt Version HSL-3-B Torque Cap HSL-3-G Stud Version Item No. Description Box Qty Item No. Description Box Qty Item No. Description Box Qty

371775 HSL-3 M 8/20 40 371807 HSL-3-B M 12/5 20 371793 HSL-3-G M 8/20 40 371776 HSL-3 M 8/40 40 371808 HSL-3-B M 12/25 20 371796 HSL-3-G M 10/20 20 371778 HSL-3 M 10/20 20 371809 HSL-3-B M 12/50 10 371799 HSL-3-G M 12/25 20 371779 HSL-3 M 10/40 20 371810 HSL-3-B M 16/10 10 371800 HSL-3-G M 12/50 10 371781 HSL-3 M 12/25 20 371811 HSL-3-B M 16/25 10 371802 HSL-3-G M 16/25 10 371782 HSL-3 M 12/50 20 371814 HSL-3-B M 20/30 6 371803 HSL-3-G M 16/50 10 371784 HSL-3 M 16/25 10 371817 HSL-3-B M 24/30 4 371805 HSL-3-G M 20/30 6 371785 HSL-3 M 16/50 10 371806 HSL-3-G M 20/60 6 371787 HSL-3 M 20/30 6 371788 HSL-3 M 20/60 6 371790 HSL-3 M 24/30 4 371791 HSL-3 M 24/60 4

Page 49: Ancore Chimice Mecanice Pentru Sarcinimari

HSL-G-R heavy-duty anchor

61

Features:

- high loading capacity

- force-controlled expansion

- reliable pull-down of part fastened

- no rotation in hole when tightening bolt

Bolt Material:

- X5CrNiMo1810, 1.4401, A4-70 DIN 267 T11

Version:

HSL-G-R: - nut

Basic loading data (for a single anchor): HSL-G-R

All data on this section applies to

concrete, fcc = 30 N/mm2

no edge distance and spacing influence correct setting (See setting operations page 65)

Characteristic resistance, Rk [kN]:

Anchor sizeConcrete,fcc [N/mm

2]

M8 M10 M12 M16 M20

20 21.3 29.5 34.3 52.5 80.9 30 22.5 32.7 41.4 66.7 102.3 40 23.8 35.8 48.4 80.8 123.6 50 25.0 39.0 55.5 95.0 145.0

Tensile, NRk

55 25.6 40.6 59.0 102.1 155.7 Shear, VRk 20 23.1 36.5 53.1 99.0 154.4

safety concept (EUROCODE 1)

M

kddF

RRSS

S actual load Sd design action (load) Rd design resistance (anchor) Rk characteristic anchor resistance NRk tensile load VRk shear load

F partial safety factor (action / load) = 1.4

M partial safety factor (resistance) = 2.15 (concrete)1.60 (steel)

non-cracked concrete

HSL-G-R

A4

316

Concrete Hilti Anchor programme

Fire resistanceCorrosion resistance

Small edge distance /spacing

Page 50: Ancore Chimice Mecanice Pentru Sarcinimari

HSL-G-R heavy-duty anchor

62

Design resistance, Rd [kN]: fcc = 30 N/mm2

Anchor size M8 M10 M12 M16 M20

Tensile, NRd 0° 10.4 15.1 19.1 30.9 47.3

30° 11.9 17.9 24.1 41.8 64.6

45° 12.6 19.3 26.6 47.3 73.3 Combinedload

60° 13.4 20.7 29.1 52.7 82.0

Shear, VRd 90° 14.9 23.5 34.1 63.6 99.3

Recommended load, F30 in [kN], fcc = 30 N/mm2

Anchor size M8 M10 M12 M16 M20

Tensile, NRec 0° 7.5 10.9 13.8 22.2 34.1

30° 8.5 12.8 17.3 30.0 46.3

45° 9.1 13.8 19.1 33.8 52.5 Combinedload

60° 9.6 14.8 20.8 37.7 58.6

Shear, VRec 90° 10.6 16.7 24.4 45.4 70.8

Recommended load for specific application

RATB30recffffFF

fT: Influence of anchorage depth

nom

actT h

hf nomactnom h1.5hh hact actual anchorage depth

Anchor size M8 M10 M12 M16 M20

hnom [mm] 65 75 80 105 130

fB: Influence of concrete strength

Anchor sizeConcrete,fcc [N/mm

2]

M8 M10 M12 M16 M20

20 7.1 9.8 11.4 17.5 27.0

30 7.5 10.9 13.8 22.2 34.1

40 7.9 11.9 16.1 26.9 41.2

50 8.3 13.0 18.5 31.7 48.3

Tensile

55 8.5 13.5 19.7 34.0 51.9

Shear 20 10.6 16.7 24.4 45.4 70.8

F

N

V

s

c

h

2

Page 51: Ancore Chimice Mecanice Pentru Sarcinimari

HSL-G-R heavy-duty anchor

63

fA: Influence of anchor spacing

Tensile / Shear

Anchor spacing, HSL-G-R

s [mm] M8 M10 M12 M16 M20

65 0.70 75 0.72 0.70 80 0.73 0.71 0.70

105 0.79 0.76 0.74 0.70 130 0.85 0.81 0.79 0.73 0.70 155 0.90 0.86 0.84 0.77 0.72 175 0.95 0.90 0.87 0.80 0.75 195 1.0 0.94 0.91 0.82 0.77 225 1.0 0.97 0.87 0.80 240 1.0 0.89 0.82 275 1.0 0.94 0.86 315 1.0 0.91 350 1.0 0.95 395 1.0 430 1.0

fR: Influence of edge distance

Tensile, fRN Shear, fRV

Edge distance, Anchor size Anchor size

c [mm] M8 M10 M12 M16 M20 M8 M10 M12 M16 M20

65 0.70 0.30 75 0.73 0.70 0.37 0.30 80 0.75 0.71 0.70 0.40 0.44 0.30

105 0.82 0.78 0.76 0.70 0.59 0.59 0.44 0.30 130 0.90 0.85 0.83 0.74 0.70 0.77 0.74 0.59 0.41 0.30 155 0.97 0.91 0.88 0.79 0.73 0.95 0.78 0.74 0.52 0.39 162 1.0 0.93 0.90 0.80 0.75 1.0 0.85 0.78 0.55 0.41 187 1.0 0.96 0.85 0.78 1.0 0.92 0.66 0.50 200 1.0 0.88 0.80 1.0 0.72 0.55 225 1.0 0.92 0.84 1.0 0.83 0.64 265 1.0 0.91 1.0 0.79 275 1.0 0.92 1.0 0.82 300 1.0 0.96 1.0 0.91 325 1.0 1.0 350 1.0 1.0

cmin = hnom, ccr = 2.5 hact. cmin = hnom, ccr = 2.5 hnom

For combined loads with influence of edge distance:90

)ff(ff RVRNRNR

There must be reinforcement in the edge of a concrete component which can take up 0.25 times the anchor load if the edge distance is equal to or less than ccr.

55.0h

s15.0f

.actA

Smin = hnom, scr = 3 hact.

Separate multiple-anchor fastenings must be at least a 2 scr apart to ensure they do not influence each other.

5.0h

c2.0f

.actRN 17.0

h

c47.0f

nomRV

Page 52: Ancore Chimice Mecanice Pentru Sarcinimari

HSL-G-R heavy-duty anchor

64

Setting details

dh

do dw

l

h

h1

hef hntfix

Tinst

HSL-G-R

Anchor size HSLG-R

Setting Details

M 8

/20

M 1

0/2

0

M 1

2/2

5

M 1

6/2

5

M 2

0/3

0

d0 [mm] Drill bit diameter 12 15 18 24 28

h1 [mm] Hole depth 80 90 100 125 155

hnom [mm] Min. anchorage depth 65 75 80 105 130

tfix [mm] Max. fixture thickness 20 20 25 25 30

l [mm] Anchor length 102 115 125 157 190

hn [mm] Head height + washer 9.5 12.0 15.0 18.0 22.0

Tinst [Nm] Tightening torque 25 40 80 120 200

Max. gap [mm] 4 5 8 9 12

Sw [mm] Width across flats 13 17 19 24 30

dh [mm] Clearance hole 14 17 20 26 31

dw [mm] Washer diameter 20 25 30 40 45

h [mm] Min. base material thickness 120 140 160 180 220

Drill bit TE-CX- 12/22 15/27 - - -

Drill bit TE-T- - - 18/32 24/32 28/32

Installation equipment

Rotary hammer (TE1, TE2, TE5, TE6, TE6A, TE15, TE15-C, TE18-M, TE35, TE55, TE76), a hammer and a torque wrench.

hnom

2

Page 53: Ancore Chimice Mecanice Pentru Sarcinimari

HSL-G-R heavy-duty anchor

61

Features:

- high loading capacity

- force-controlled expansion

- reliable pull-down of part fastened

- no rotation in hole when tightening bolt

Bolt Material:

- X5CrNiMo1810, 1.4401, A4-70 DIN 267 T11

Version:

HSL-G-R: - nut

Basic loading data (for a single anchor): HSL-G-R

All data on this section applies to

concrete, fcc = 30 N/mm2

no edge distance and spacing influence correct setting (See setting operations page 65)

Characteristic resistance, Rk [kN]:

Anchor sizeConcrete,fcc [N/mm

2]

M8 M10 M12 M16 M20

20 21.3 29.5 34.3 52.5 80.9 30 22.5 32.7 41.4 66.7 102.3 40 23.8 35.8 48.4 80.8 123.6 50 25.0 39.0 55.5 95.0 145.0

Tensile, NRk

55 25.6 40.6 59.0 102.1 155.7 Shear, VRk 20 23.1 36.5 53.1 99.0 154.4

safety concept (EUROCODE 1)

M

kddF

RRSS

S actual load Sd design action (load) Rd design resistance (anchor) Rk characteristic anchor resistance NRk tensile load VRk shear load

F partial safety factor (action / load) = 1.4

M partial safety factor (resistance) = 2.15 (concrete)1.60 (steel)

non-cracked concrete

HSL-G-R

A4

316

Concrete Hilti Anchor programme

Fire resistanceCorrosion resistance

Small edge distance /spacing

Page 54: Ancore Chimice Mecanice Pentru Sarcinimari

HSL-G-R heavy-duty anchor

62

Design resistance, Rd [kN]: fcc = 30 N/mm2

Anchor size M8 M10 M12 M16 M20

Tensile, NRd 0° 10.4 15.1 19.1 30.9 47.3

30° 11.9 17.9 24.1 41.8 64.6

45° 12.6 19.3 26.6 47.3 73.3 Combinedload

60° 13.4 20.7 29.1 52.7 82.0

Shear, VRd 90° 14.9 23.5 34.1 63.6 99.3

Recommended load, F30 in [kN], fcc = 30 N/mm2

Anchor size M8 M10 M12 M16 M20

Tensile, NRec 0° 7.5 10.9 13.8 22.2 34.1

30° 8.5 12.8 17.3 30.0 46.3

45° 9.1 13.8 19.1 33.8 52.5 Combinedload

60° 9.6 14.8 20.8 37.7 58.6

Shear, VRec 90° 10.6 16.7 24.4 45.4 70.8

Recommended load for specific application

RATB30recffffFF

fT: Influence of anchorage depth

nom

actT h

hf nomactnom h1.5hh hact actual anchorage depth

Anchor size M8 M10 M12 M16 M20

hnom [mm] 65 75 80 105 130

fB: Influence of concrete strength

Anchor sizeConcrete,fcc [N/mm

2]

M8 M10 M12 M16 M20

20 7.1 9.8 11.4 17.5 27.0

30 7.5 10.9 13.8 22.2 34.1

40 7.9 11.9 16.1 26.9 41.2

50 8.3 13.0 18.5 31.7 48.3

Tensile

55 8.5 13.5 19.7 34.0 51.9

Shear 20 10.6 16.7 24.4 45.4 70.8

F

N

V

s

c

h

2

Page 55: Ancore Chimice Mecanice Pentru Sarcinimari

HSL-G-R heavy-duty anchor

63

fA: Influence of anchor spacing

Tensile / Shear

Anchor spacing, HSL-G-R

s [mm] M8 M10 M12 M16 M20

65 0.70 75 0.72 0.70 80 0.73 0.71 0.70

105 0.79 0.76 0.74 0.70 130 0.85 0.81 0.79 0.73 0.70 155 0.90 0.86 0.84 0.77 0.72 175 0.95 0.90 0.87 0.80 0.75 195 1.0 0.94 0.91 0.82 0.77 225 1.0 0.97 0.87 0.80 240 1.0 0.89 0.82 275 1.0 0.94 0.86 315 1.0 0.91 350 1.0 0.95 395 1.0 430 1.0

fR: Influence of edge distance

Tensile, fRN Shear, fRV

Edge distance, Anchor size Anchor size

c [mm] M8 M10 M12 M16 M20 M8 M10 M12 M16 M20

65 0.70 0.30 75 0.73 0.70 0.37 0.30 80 0.75 0.71 0.70 0.40 0.44 0.30

105 0.82 0.78 0.76 0.70 0.59 0.59 0.44 0.30 130 0.90 0.85 0.83 0.74 0.70 0.77 0.74 0.59 0.41 0.30 155 0.97 0.91 0.88 0.79 0.73 0.95 0.78 0.74 0.52 0.39 162 1.0 0.93 0.90 0.80 0.75 1.0 0.85 0.78 0.55 0.41 187 1.0 0.96 0.85 0.78 1.0 0.92 0.66 0.50 200 1.0 0.88 0.80 1.0 0.72 0.55 225 1.0 0.92 0.84 1.0 0.83 0.64 265 1.0 0.91 1.0 0.79 275 1.0 0.92 1.0 0.82 300 1.0 0.96 1.0 0.91 325 1.0 1.0 350 1.0 1.0

cmin = hnom, ccr = 2.5 hact. cmin = hnom, ccr = 2.5 hnom

For combined loads with influence of edge distance:90

)ff(ff RVRNRNR

There must be reinforcement in the edge of a concrete component which can take up 0.25 times the anchor load if the edge distance is equal to or less than ccr.

55.0h

s15.0f

.actA

Smin = hnom, scr = 3 hact.

Separate multiple-anchor fastenings must be at least a 2 scr apart to ensure they do not influence each other.

5.0h

c2.0f

.actRN 17.0

h

c47.0f

nomRV

Page 56: Ancore Chimice Mecanice Pentru Sarcinimari

HSL-G-R heavy-duty anchor

64

Setting details

dh

do dw

l

h

h1

hef hntfix

Tinst

HSL-G-R

Anchor size HSLG-R

Setting Details

M 8

/20

M 1

0/2

0

M 1

2/2

5

M 1

6/2

5

M 2

0/3

0

d0 [mm] Drill bit diameter 12 15 18 24 28

h1 [mm] Hole depth 80 90 100 125 155

hnom [mm] Min. anchorage depth 65 75 80 105 130

tfix [mm] Max. fixture thickness 20 20 25 25 30

l [mm] Anchor length 102 115 125 157 190

hn [mm] Head height + washer 9.5 12.0 15.0 18.0 22.0

Tinst [Nm] Tightening torque 25 40 80 120 200

Max. gap [mm] 4 5 8 9 12

Sw [mm] Width across flats 13 17 19 24 30

dh [mm] Clearance hole 14 17 20 26 31

dw [mm] Washer diameter 20 25 30 40 45

h [mm] Min. base material thickness 120 140 160 180 220

Drill bit TE-CX- 12/22 15/27 - - -

Drill bit TE-T- - - 18/32 24/32 28/32

Installation equipment

Rotary hammer (TE1, TE2, TE5, TE6, TE6A, TE15, TE15-C, TE18-M, TE35, TE55, TE76), a hammer and a torque wrench.

hnom

2

Page 57: Ancore Chimice Mecanice Pentru Sarcinimari

HSL-G-R heavy-duty anchor

65

Drill hole with drill bit. Blow out dust and fragments. Install anchor. Apply tightening torque

Anchor mechanical properties

Anchor size HSL-G-R M 8 M 10 M 12 M 16 M 20

fuk [N/mm2] Nominal tensile strength 700 700 700 700 700

fyk [N/mm2] Yield strength 450 450 450 450 450

As [mm2] Stressed cross-section 36.6 58.0 84.3 157 245

W [mm3] Effective moment of resistance 106 231 390 965 1421

Md [Nm] Design bending moment 41 90 150 375 550

Page 58: Ancore Chimice Mecanice Pentru Sarcinimari

HSL-G-R heavy-duty anchor

65

Drill hole with drill bit. Blow out dust and fragments. Install anchor. Apply tightening torque

Anchor mechanical properties

Anchor size HSL-G-R M 8 M 10 M 12 M 16 M 20

fuk [N/mm2] Nominal tensile strength 700 700 700 700 700

fyk [N/mm2] Yield strength 450 450 450 450 450

As [mm2] Stressed cross-section 36.6 58.0 84.3 157 245

W [mm3] Effective moment of resistance 106 231 390 965 1421

Md [Nm] Design bending moment 41 90 150 375 550

Page 59: Ancore Chimice Mecanice Pentru Sarcinimari

HSL-I heavy duty anchor

66 Issue 2005

Basic loading data (for a single anchor): HSL-I

All data on this page applies to

concrete: as specified in the table no edge distance and spacing influence correct setting (See setting operations page 68)

steel failure

Characteristic resistance, Rk [kN]: concrete C20/25

Anchor size M12 M12

hnom 65 80

Tensile NRk 26.0 34.0 Shear VRk 34.0 34.0

Following values according to the

Concrete Capacity Method

Design resistance, Rd [kN]: concrete fck,cube=25N/mm2

Anchor size M12 M12

hnom 65 80

Tensile NRd 17.3 22.7 Shear VRd 27.2 27.2

Recommended load Lrec [kN]: concrete fck,cube=25N/mm2

Anchor size M12 M12

hnom 65 80

Tensile NRec 12.4 16.2 Shear VRec 19.4 19.4

non-cracked concrete

Features:

- high loading capacity

- force controlled expansion

- no rotation in hole when tightening torque

Material:

Nut: - carbon steel, grade 8.8

Washer: - carbon steel acc. ASTM F 844

Anchor Body: - carbon steel, grade 8.8

Cone: - carbon steel C45PB

Expansion Sleeve: - ST 52-3

Threaded Rod: - grade 8.8

Star washer: - stainless steel

Bolt material:- grade 8.8 acc. DIN EN ISO 898-1 galvanised to min.5 microns

Versions:

-HSL-I M12/0*65

-HSL-I M12/0*80

HSL-I

Concrete HiltiAnchor

programme

Page 60: Ancore Chimice Mecanice Pentru Sarcinimari

HSL-I heavy duty anchor

Issue 2005 67

2

Setting details

HSL-I

HSL-I M12x65 HSL-I M12x80

d0 Nominal bit diameter (mm) 18 18

(mm) 65 80 hnom embedment depth

(in.) 2.56 3.15

(mm) 80 95 h1 Hole depth

(in.) 3.15 3.74

(mm) 130 160 hmin ;

minimum base material thickness (in.) 5 1/8 6 1/4

(mm) 20 20 dh

wedge clearance hole in plate (in.) 0.79 0.79

(Nm) 80 80 Tinst Installation Torque

(ft/*lb) 60 60

Wrench size (for nut) (mm) 19 19

allen wrench size (for socket) (mm) 6 6

Washer diameter (mm) 30 30

Installation equipment

Rotary hammer (TE1, TE2, TE5, TE6, TE6A, TE15, TE15-C, TE18-M or TE35), a blow out pump,

hmin

h1

hef

hmin

Page 61: Ancore Chimice Mecanice Pentru Sarcinimari

HSL-I heavy duty anchor

68 Issue 2005

Drill hole. Remove dust and debris

usingcompressed air or blow

pump.

Hammer in anchor.

Insert Allen wrench into the

anchor.

Turn the Allen wrench until resistance is

exerted.

Place fixture and insert the threaded rod

into the anchor.

Using the appropriate torque nut, apply torque until the upper

section of torque nut shears of.

Detailed design method - Hilti CC

TENSION

The tensile design resistance of a single anchor is the lower of,

NRd,p : concrete pull-out resistance

NRd,c : concrete cone resistance

NRd,s : steel resistance

NRd,p : Pull-out resistance Pull-out failure mode not determinating

NRd,c : Concrete cone resistance

RNANBo

c,Rdc,Rd fffNN

Setting operations

Page 62: Ancore Chimice Mecanice Pentru Sarcinimari

HSL-I heavy duty anchor

66 Issue 2005

Basic loading data (for a single anchor): HSL-I

All data on this page applies to

concrete: as specified in the table no edge distance and spacing influence correct setting (See setting operations page 68)

steel failure

Characteristic resistance, Rk [kN]: concrete C20/25

Anchor size M12 M12

hnom 65 80

Tensile NRk 26.0 34.0 Shear VRk 34.0 34.0

Following values according to the

Concrete Capacity Method

Design resistance, Rd [kN]: concrete fck,cube=25N/mm2

Anchor size M12 M12

hnom 65 80

Tensile NRd 17.3 22.7 Shear VRd 27.2 27.2

Recommended load Lrec [kN]: concrete fck,cube=25N/mm2

Anchor size M12 M12

hnom 65 80

Tensile NRec 12.4 16.2 Shear VRec 19.4 19.4

non-cracked concrete

Features:

- high loading capacity

- force controlled expansion

- no rotation in hole when tightening torque

Material:

Nut: - carbon steel, grade 8.8

Washer: - carbon steel acc. ASTM F 844

Anchor Body: - carbon steel, grade 8.8

Cone: - carbon steel C45PB

Expansion Sleeve: - ST 52-3

Threaded Rod: - grade 8.8

Star washer: - stainless steel

Bolt material:- grade 8.8 acc. DIN EN ISO 898-1 galvanised to min.5 microns

Versions:

-HSL-I M12/0*65

-HSL-I M12/0*80

HSL-I

Concrete HiltiAnchor

programme

Page 63: Ancore Chimice Mecanice Pentru Sarcinimari

HSL-I heavy duty anchor

Issue 2005 67

2

Setting details

HSL-I

HSL-I M12x65 HSL-I M12x80

d0 Nominal bit diameter (mm) 18 18

(mm) 65 80 hnom embedment depth

(in.) 2.56 3.15

(mm) 80 95 h1 Hole depth

(in.) 3.15 3.74

(mm) 130 160 hmin ;

minimum base material thickness (in.) 5 1/8 6 1/4

(mm) 20 20 dh

wedge clearance hole in plate (in.) 0.79 0.79

(Nm) 80 80 Tinst Installation Torque

(ft/*lb) 60 60

Wrench size (for nut) (mm) 19 19

allen wrench size (for socket) (mm) 6 6

Washer diameter (mm) 30 30

Installation equipment

Rotary hammer (TE1, TE2, TE5, TE6, TE6A, TE15, TE15-C, TE18-M or TE35), a blow out pump,

hmin

h1

hef

hmin

Page 64: Ancore Chimice Mecanice Pentru Sarcinimari

HSL-I heavy duty anchor

68 Issue 2005

Drill hole. Remove dust and debris

usingcompressed air or blow

pump.

Hammer in anchor.

Insert Allen wrench into the

anchor.

Turn the Allen wrench until resistance is

exerted.

Place fixture and insert the threaded rod

into the anchor.

Using the appropriate torque nut, apply torque until the upper

section of torque nut shears of.

Detailed design method - Hilti CC

TENSION

The tensile design resistance of a single anchor is the lower of,

NRd,p : concrete pull-out resistance

NRd,c : concrete cone resistance

NRd,s : steel resistance

NRd,p : Pull-out resistance Pull-out failure mode not determinating

NRd,c : Concrete cone resistance

RNANBo

c,Rdc,Rd fffNN

Setting operations

Page 65: Ancore Chimice Mecanice Pentru Sarcinimari

HSL-I heavy duty anchor

66 Issue 2005

Basic loading data (for a single anchor): HSL-I

All data on this page applies to

concrete: as specified in the table no edge distance and spacing influence correct setting (See setting operations page 68)

steel failure

Characteristic resistance, Rk [kN]: concrete C20/25

Anchor size M12 M12

hnom 65 80

Tensile NRk 26.0 34.0 Shear VRk 34.0 34.0

Following values according to the

Concrete Capacity Method

Design resistance, Rd [kN]: concrete fck,cube=25N/mm2

Anchor size M12 M12

hnom 65 80

Tensile NRd 17.3 22.7 Shear VRd 27.2 27.2

Recommended load Lrec [kN]: concrete fck,cube=25N/mm2

Anchor size M12 M12

hnom 65 80

Tensile NRec 12.4 16.2 Shear VRec 19.4 19.4

non-cracked concrete

Features:

- high loading capacity

- force controlled expansion

- no rotation in hole when tightening torque

Material:

Nut: - carbon steel, grade 8.8

Washer: - carbon steel acc. ASTM F 844

Anchor Body: - carbon steel, grade 8.8

Cone: - carbon steel C45PB

Expansion Sleeve: - ST 52-3

Threaded Rod: - grade 8.8

Star washer: - stainless steel

Bolt material:- grade 8.8 acc. DIN EN ISO 898-1 galvanised to min.5 microns

Versions:

-HSL-I M12/0*65

-HSL-I M12/0*80

HSL-I

Concrete HiltiAnchor

programme

Page 66: Ancore Chimice Mecanice Pentru Sarcinimari

HSL-I heavy duty anchor

66 Issue 2005

Basic loading data (for a single anchor): HSL-I

All data on this page applies to

concrete: as specified in the table no edge distance and spacing influence correct setting (See setting operations page 68)

steel failure

Characteristic resistance, Rk [kN]: concrete C20/25

Anchor size M12 M12

hnom 65 80

Tensile NRk 26.0 34.0 Shear VRk 34.0 34.0

Following values according to the

Concrete Capacity Method

Design resistance, Rd [kN]: concrete fck,cube=25N/mm2

Anchor size M12 M12

hnom 65 80

Tensile NRd 17.3 22.7 Shear VRd 27.2 27.2

Recommended load Lrec [kN]: concrete fck,cube=25N/mm2

Anchor size M12 M12

hnom 65 80

Tensile NRec 12.4 16.2 Shear VRec 19.4 19.4

non-cracked concrete

Features:

- high loading capacity

- force controlled expansion

- no rotation in hole when tightening torque

Material:

Nut: - carbon steel, grade 8.8

Washer: - carbon steel acc. ASTM F 844

Anchor Body: - carbon steel, grade 8.8

Cone: - carbon steel C45PB

Expansion Sleeve: - ST 52-3

Threaded Rod: - grade 8.8

Star washer: - stainless steel

Bolt material:- grade 8.8 acc. DIN EN ISO 898-1 galvanised to min.5 microns

Versions:

-HSL-I M12/0*65

-HSL-I M12/0*80

HSL-I

Concrete HiltiAnchor

programme

Page 67: Ancore Chimice Mecanice Pentru Sarcinimari

HSL-I heavy duty anchor

Issue 2005 67

2

Setting details

HSL-I

HSL-I M12x65 HSL-I M12x80

d0 Nominal bit diameter (mm) 18 18

(mm) 65 80 hnom embedment depth

(in.) 2.56 3.15

(mm) 80 95 h1 Hole depth

(in.) 3.15 3.74

(mm) 130 160 hmin ;

minimum base material thickness (in.) 5 1/8 6 1/4

(mm) 20 20 dh

wedge clearance hole in plate (in.) 0.79 0.79

(Nm) 80 80 Tinst Installation Torque

(ft/*lb) 60 60

Wrench size (for nut) (mm) 19 19

allen wrench size (for socket) (mm) 6 6

Washer diameter (mm) 30 30

Installation equipment

Rotary hammer (TE1, TE2, TE5, TE6, TE6A, TE15, TE15-C, TE18-M or TE35), a blow out pump,

hmin

h1

hef

hmin

Page 68: Ancore Chimice Mecanice Pentru Sarcinimari

HSL-I heavy duty anchor

68 Issue 2005

Drill hole. Remove dust and debris

usingcompressed air or blow

pump.

Hammer in anchor.

Insert Allen wrench into the

anchor.

Turn the Allen wrench until resistance is

exerted.

Place fixture and insert the threaded rod

into the anchor.

Using the appropriate torque nut, apply torque until the upper

section of torque nut shears of.

Detailed design method - Hilti CC

TENSION

The tensile design resistance of a single anchor is the lower of,

NRd,p : concrete pull-out resistance

NRd,c : concrete cone resistance

NRd,s : steel resistance

NRd,p : Pull-out resistance Pull-out failure mode not determinating

NRd,c : Concrete cone resistance

RNANBo

c,Rdc,Rd fffNN

Setting operations

Page 69: Ancore Chimice Mecanice Pentru Sarcinimari

HSL-I heavy duty anchor

Issue 2005 69

2

N0Rd,c : Design concrete cone resistance

Concrete compressive strength. fck.cube(150) = 25 N/mm2

Anchor size M12 M12

hnom 65 80

N0Rd,c

1) 17.3 22.7 1) The design tensile resistance for concrete is calculated from the characteristic concrete tensile resistance N0

Rk,c divided by the partial safety factor Mc,N N0

Rd,c s = N0Rk,c s/ Mc,N, where Ms = 1.5.

fB : Influence of concrete strength

1.0fB

fAN: Influence of anchor spacing

Anchor

spacing

Anchor size

s [mm]

M12

hnom=65mm

M12

hnom=80mm

85 0.71 0.67 90 0.73 0.69

100 0.76 0.71 110 0.78 0.73 125 0.82 0.76 140 0.86 0.79 160 0.91 0.83 180 0.96 0.88 200 0.52 220 0.96 240 1.00

fRN : Influence of edge distance cmin>ccr,N therefore no influence of edge distance

Minimum edge distanceAnchor size M12 M12

hnom 65 80

cmin 100 120

NRd,s : Steel design tensile resistance

Anchor size M12 M12

hnom 65 80

NRd,s1) 45.0 45.0

1) The design tensile resistance for steel is calculated from the characteristic tensile resistance NRk,s divided by the partial safety factor Ms

NRd,s = NRk,s/ Ms, where Ms = 1.5.

NRd : System design tensile resistance

NRd = lower of NRd,c and NRd,s

Combined loading: See end of this chapter.

efN,A h6

s5.0f

Limits: N,crmin sss

smin=85mmscr;N=3hef

Page 70: Ancore Chimice Mecanice Pentru Sarcinimari

HSL-I heavy duty anchor

70 Issue 2005

VRd,c : Concrete edge design resistance

The lowest concrete edge resistance must be calculated. All nearby edges must be checked (not only the

edge in the direction of shear). Shear direction is accounted for by the factor f ,V.

V,ARV,Bo

c,Rdc,Rd fffVV

V0Rd,c : Concrete edge design resistance

Concrete compressive strength fck,cube(150) = 25 N/mm2

at a minimum edge distance minc

Anchor size M12 M12

hnom 65 80

V0Rd,c

1) 10.2 14.3 cmin 100 125

1) The design value for the ultimate state in concrete shear is calculated from the characteristic concrete shear resistance V0Rk,c divided by

Mc,V V0Rd,c = V0

Rk,c/ Mc,V; where Mc,V = 1.5.

fB : Influence of concrete strength

1.0fB

f ,V : Influence of shear load direction

Angle [°] f .V

0 to 55 1

60 1.1

70 1.2

80 1.5

90 to 180 2

Formulae:

1f V,

sin5.0cos

1f V,

2f V,

for 0° 55°

for 55° < 90°

for 90° < 180°

fAR,V : Influence of spacing and edge

distance

Formula for single anchor fasteninginfluenced only by edge

minminV,AR

c

c

c

cf

Formula for two-anchor fastening valid for s < 3c

minminV,AR c

c

c6

sc3f

Results for single anchor and two anchor fastening tabled below.

V ... applied shear force

Detailed design method – Hilti CC

SHEAR

The design shear resistance of a single anchor is the lower of:

VRd,c : concrete edge resistance

VRd,s : steel resistance

V

cs

rec,c/sc >1.5c2

c >1.5c2

h>1.5c

Note: If the conditions regarding h and c2 are not met. consult your Hilti technical advisory service.

(The Hilti CC-Method is a simplified Version of ETAG Annex C)

Page 71: Ancore Chimice Mecanice Pentru Sarcinimari

HSL-I heavy duty anchor

Issue 2005 71

fAR.V c/cmin

1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 3.2 3.4 3.6 3.8 4.0

Single anchor with edge influence 1.00 1.31 1.66 2.02 2.41 2.83 3.26 3.72 4.19 4.69 5.20 5.72 6.27 6.83 7.41 8.00

s/cmin 1.0 0.67 0.84 1.03 1.22 1.43 1.65 1.88 2.12 2.36 2.62 2.89 3.16 3.44 3.73 4.03 4.331.5 0.75 0.93 1.12 1.33 1.54 1.77 2.00 2.25 2.50 2.76 3.03 3.31 3.60 3.89 4.19 4.502.0 0.83 1.02 1.22 1.43 1.65 1.89 2.13 2.38 2.63 2.90 3.18 3.46 3.75 4.05 4.35 4.672.5 0.92 1.11 1.32 1.54 1.77 2.00 2.25 2.50 2.77 3.04 3.32 3.61 3.90 4.21 4.52 4.833.0 1.00 1.20 1.42 1.64 1.88 2.12 2.37 2.63 2.90 3.18 3.46 3.76 4.06 4.36 4.68 5.003.5 1.30 1.52 1.75 1.99 2.24 2.50 2.76 3.04 3.32 3.61 3.91 4.21 4.52 4.84 5.174.0 1.62 1.86 2.10 2.36 2.62 2.89 3.17 3.46 3.75 4.05 4.36 4.68 5.00 5.334.5 1.96 2.21 2.47 2.74 3.02 3.31 3.60 3.90 4.20 4.52 4.84 5.17 5.505.0 2.33 2.59 2.87 3.15 3.44 3.74 4.04 4.35 4.67 5.00 5.33 5.675.5 2.71 2.99 3.28 3.57 3.88 4.19 4.50 4.82 5.15 5.49 5.836.0 2.83 3.11 3.41 3.71 4.02 4.33 4.65 4.98 5.31 5.65 6.006.5 3.24 3.54 3.84 4.16 4.47 4.80 5.13 5.47 5.82 6.177.0 3.67 3.98 4.29 4.62 4.95 5.29 5.63 5.98 6.337.5 4.11 4.43 4.76 5.10 5.44 5.79 6.14 6.508.0 4.57 4.91 5.25 5.59 5.95 6.30 6.678.5 5.05 5.40 5.75 6.10 6.47 6.839.0 5.20 5.55 5.90 6.26 6.63 7.009.5 5.69 6.05 6.42 6.79 7.17

10.0 6.21 6.58 6.95 7.3310.5 6.74 7.12 7.5011.0 7.28 7.6711.5 7.8312.0 8.00

VRd,s1) : Steel design shear resistance

Anchor size M12 M12

hnom 65 80

VRd,s1) 27.2 27.2

1) The design shear resistance is calculated from VRd,s= VRk,s/ Ms,V. The partial safety factor Ms,V is 1.25.

VRd : System design shear resistance VRd : System design shear resistance

VRd = lower of VRd,c and VRd,s

Combined loading

1.0V

V

N

N1,5

Rd

Sd

1,5

Rd

Sd

These results are for a two-. Anchor fastening.

For fastening made with more than 2 anchors, use the general formulae for n anchors the page before.

General formula for n anchors (edge distance plus n-1 spacing) only valid where s1 to sn-1 are all < 3c and c2 > 1.5c

minmin

1n21V,AR c

c

nc3

s...ssc3f

ccs

ss

2,2

1

2

3

n-1sc2,1

h >1,5 c

Note: It is assumed that only the row of anchors closest to the free concrete edge carries the centric shear load 2

Page 72: Ancore Chimice Mecanice Pentru Sarcinimari

HVU adhesive with HAS-R/-HCR rod underwater

254 Issue 2005

Features

- underwater fastening

- no loss of holding power from curing under water

- for permanently damp or wet fastenings /

applications

- suitable for sea water

- exerts very low expansion forces

- small edge distances and spacing

- externally tested and approved

Material

HAS-R: - stainless steel; A4-70; 1.4401, 1.4404, 1.4571

HAS-HCR: - stainless steel; 1.4529

HVU Capsule - urethane methacrylate resin, styrene free, hardener, quartz sand or corundum, foil tube

Mortar: - Hilti HIT HY 20, standard size 330 ml

Dispenser: - MD 2000

Setting details

Anchor size

Setting detail

M 8 M 10 M 12 M 16 M 20 M 24

Foil capsule HVU M 8 X 80 M 10 x 90 M 12 x 110 M 16 x 125 M 20 x 170 M 24 x 210

d0 [mm] Drill bit diameter 10 12 14 18 24 28

h1 [mm] Hole depth 80 90 110 125 170 210

tfix1) [mm] Max. fixture thickness 14 21 28 38 48 54

df [mm] Max. clearance hole 11 13 15 19 26 29

l [mm] Anchor length 110 130 160 190 240 290

Tinst [Nm] Tightening torque 18 35 60 120 260 450

Sw [mm] Width across flats 13 17 19 24 30 36

hmin [mm]Min. thickness of basematerial

100 120 140 170 220 270

Drill bit and drilling machine Suitable commercially available tools must be used under water

Pre-injection with Hilti HY 20

Trigger pulls with MD 2000 / P 3000 UW/F 1 1 2 3 5 8

1) The values for the total rod length and the maximum fixture thickness are only valid for the HAS anchor rods given in this table. If other HAS rods are used, these values will change. (Example: HAS M12 x 260/128; l = 260 mm and tfix = 128 mm)

Setting temperature:(water temperature) Curing time until full loading:

-5° C to 0° C 10 hours

0° C to 10° C 2 hours

10° C to 20° C 1 hours

20° C and above 30 minutes

HCRhighMo

ConcreteHigh corrosion

resistance

Small edge distance/spacing

A4316

Corrosionresistance

d0

df

h

h

tfix

min

Page 73: Ancore Chimice Mecanice Pentru Sarcinimari

HVU adhesive with HAS-R/-HCR rod underwater

Issue 2005 255

3

Setting operations

Drill hole. Clean hole. Inject HIT-HY 20 (observe number of trigger pulls).

Insert HVU capsule.

HIT-HY 20 adhesive mortar displaces water in hole.

Insert HAS-R (HAS-HCR) threaded rod.

Remove setting tool (after trel).Set threaded rod with part

fastened.

Design: See “HVU adhesive with HAS rod” (no additional load reduction applicable)

Page 74: Ancore Chimice Mecanice Pentru Sarcinimari

HVU adhesive with HIS-RN sleeve underwater

256 Issue 2005

Design: See “HVU adhesive with HIS-N/HIS-RN sleeve” (no load additional reduction applicable)

HIT-HY 20 adhesive mortar displaces water in hole.

Insert HIS-RN threaded rod. Remove setting tool (after trel).Set threaded rod with part

fastened.

Drill hole. Clean hole. Inject HIT-HY 20 (observe number of trigger pulls).

Insert HVU capsule.

Setting operations

Setting details

Anchor size

Setting detail

M 8 M 10 M 12 M 16 M 20

Capsule HVU M 10 x 90 M 12 x 110 M 16 x 125 M 20 x 170 M 24 x 210

d0 [mm] Drill bit diameter 14 18 22 28 32

h1 [mm] Hole depth 90 110 125 170 205

Tinst [Nm] Tightening torque 12 23 40 70 130

hmin [mm]Min. thickness of basematerial

120 150 170 230 280

hs [mm] Thread engagement min. 8 10 12 16 20

max. 20 25 30 40 50

Drill bit and drilling machine Suitable commercially available tools must be used under water

Pre-injection with Hilti HY 20

Trigger pulls with MD 2000 1 1 2 3 5

Setting temperature: -5° C to 0° C Curing time until full 10 hours

(water temperature) 0° C to 10° C loading: 2 hours

10° C to 20° C 1 hours

20° C and above 30 minutes

Features

- underwater fastening

- no loss of holding power from curing under water

- for permanently damp or wet fastenings /

applications

- suitable for sea water

- exerts very low expansion farces

- small edge distances spacing

- fastenings flush with work surface

Material

HIS-RN: - stainless steel, A4-70: 1.4401

HVU Capsule - urethane methacrylate resin, styrene free, hardener, quartz sand or corundum, foil tube

Mortar: - Hilti HIT HY 20, standard size 330 ml

Dispenser: - MD 2000

A4316

Concrete Corrosionresistance

Small edge distance/ spacing

hs

dfd0

min

h1h

nomh

Page 75: Ancore Chimice Mecanice Pentru Sarcinimari

HVU adhesive with rebar

218 Issue 2005

Features:

- complete ready-to-use rebar fastening

- foil capsule vs. glass

- no expansion force in base material

- high loading capacity

- small edge distance and spacing

Material:

Rebar:- Type BSt 500 according to DIN 488 (See also Euronorm 82-79). For differing rebars, consult your Hilti advisory service.

HVU Capsule: - urethane methacrylate resin, styrene free, hardener, quartz sand or corundum, foil tube

HVU capsule

Rebar section

Concrete Small edge distance / spacing/

Fire resistanceHilti Anchor programme

Basic loading data (for a single anchor): HVU capsule with rebar section

All data on this page applies to For detailed design method, see pages 220 – 224. concrete: See table below. correct setting (See setting operations page 219) no edge distance and spacing influence

steel failure

Mean ultimate resistance, Ru,m [kN]: concrete C20/25

Rebar diameter (mm)

10 12 14 16 20 25 28 32 36

Tensile, NRu,m 33.4 66.0 98.9 99.9 176.8 216.3 378.9 449.1 528.7 Shear, VRu,m 28.1 40.4 55.0 71.8 112.3 175.0 219.2 286.3 384.5

Characteristic resistance, Rk [kN]: concrete C20/25

Rebar diameter (mm)

10 12 14 16 20 25 28 32 36

Tensile, NRk 15.9 50.1 69.7 68.4 128.1 128.0 259.1 312.1 372.3 Shear, VRk 26.0 37.4 50.9 66.5 104.0 162.0 203.0 265.1 356.0

Following values according to the

Concrete Capacity Method

Design resistance, Rd [kN]: concrete, fck,cube = 25 N/mm2

Rebar diameter (mm)

10 12 14 16 20 25 28 32 36

Tensile, NRd 15.0 23.0 31.4 34.9 59.3 91.6 115.4 136.1 158.3 Shear, VRd 17.3 24.9 33.9 44.3 69.3 108.0 135.3 176.7 237.3

Recommended load, Lrec [kN]: concrete, fck,cube = 25 N/mm2

Rebar diameter (mm)

10 12 14 16 20 25 28 32 36

Tensile, NRec 10.7 16.4 22.4 24.9 42.3 65.4 82.4 97.2 113.1 Shear, VRec 12.4 17.8 24.2 31.6 49.5 77.1 96.6 126.2 169.5

non-cracked concrete

Page 76: Ancore Chimice Mecanice Pentru Sarcinimari

HVU adhesive with rebar

Issue 2005 219

3

h1

h

d0

0 d /

Setting details

Rebar size, [mm] 10 12 14 16 20 25 28 32 36

Capsule HVU... M10x90 M12x110 M16x125 M16x125 M20x170 M24x210 M30x270 M33x330 M39x360

d0 [mm] Drill bit diameter 12 16 18 20 25 30 35 40 42

h1 [mm] Hole depth 90 110 125 125 170 210 270 300 360

hmin [mm] Min. thickness of base material

120 140 170 170 220 270 340 380 460

TE-CX- 12/22 15/27 - - - - - - - Drill bit

TE-T- - - 18/32 20/32 25/52 30/57 - - -

Recommended diamond drilling machine DD 80 E // DD 160 E

Temperature when setting:

Min. time to wait before removing SCREWED-ON

setting tool, trel

Curing time before anchor can be fully loaded,

tcure

20°C and above10°C to 20°C0°C to 10°C-5°C to 0°C

8 min. 20 min. 30 min. 1 hour

20 min. 30 min. 1 hour 5 hours

less than -5°C Contact your Hilti advisory service.

Installation equipment

Rotary hammer (TE5, TE6, TE6A, TE15, TE15-C, TE18-M, TE 35, TE 55 or TE 76) or a diamond drilling machine, a drill bit and a blow-out pump. Pre-cut thread on rebar, nut welded on rebar and rebar adapter.

Setting operations

1 2 3HVU

5 REBAR4

Drill hole. Blow out dust and

fragments.Insert HVU capsule. Drive in the rebar section.

5 trel 6 tcure

Allow gel time to pass.

Wait for curing.

min

hnom

Page 77: Ancore Chimice Mecanice Pentru Sarcinimari

HVU adhesive with rebar

220 Issue 2005

Anchor geometry and mechanical properties

Rebar diameter [mm] 10 12 14 16 20 25 28 32 36

HVU capsule M10x90 M12x110 M16x125 M16x125 M20x170 M24x210 M30x270 M33x330 M39x360

lp [mm] HVU capsule length 110 127 140 140 170 200 260 290 320

d [mm] Nominal rebar diameter 10,7 13,1 17,1 17,1 22 25,7 31,5 31,5 35

Rebar section

Ø d [mm] Nominal rebar diameter 10 12 14 16 20 25 28 32 36

As [mm²] Stressed cross-section 78,5 113,1 153,9 201,1 314,2 490,9 615,8 804,2 1017,9

fuk [N/mm²] Nominal tensile strength 550

fyk [N/mm²] Yield strength 500

Detailed design method - Hilti CC

Caution: In view of the high loads transferable with the HVU, it must be verified by the user that the load acting on the concrete structure, including the loads introduced by the anchor fastening, do not cause failure, e.g. cracking, of the concrete structure.

TENSION

The design tensile resistance of a single anchoris the lower of

NRd,c : concrete cone/pull-out resistance

NRd,s : steel resistance

NRd,c: Concrete cone/pull-out resistance

N,RN,AN,BTo

c,Rdc,Rd ffffNN

N0Rd,c: Concrete cone/pull-out design resistance

Concrete compressive strength, fck,cube(150) = 25 N/mm2

Rebar diameter [mm] 10 12 14 16 20 25 28 32 36

NoRd,c

1) [kN] 15.0 23.0 31.4 34.9 59.3 91.6 115.4 136.1 158.3

hnom [mm] Nominal anchorage depth 90 110 125 125 170 210 270 300 360 1) The design tensile resistance is calculated from the characteristic tensile resistance, No

Rk,c , by NoRd,c= No

Rk,c/ Mc,N, where the partial safety factor, Mc,N , is 1.8.

(The Hilti CC method is a simplified version of ETAG Annex C.)

anchorage depth addtional lengthaccording to application

d

dp

lp

HVU M..HVU M.. HVU M..

N

cs

h

rec,c/s

Page 78: Ancore Chimice Mecanice Pentru Sarcinimari

HVU adhesive with rebar

Issue 2005 221

3

fT: Influence of anchorage depth

nom

actT

h

hf Limits to actual anchorage depth hact: hnom hact 2.0hnom

fB,N : Influence of concrete strength

Concrete strength designation(ENV 206)

Cylinder compressive strength,

fck,cyl [N/mm²]

Cube compressive strength,

fck,cube [N/mm²] fB,N

C20/25 20 25 1

C25/30 25 30 1,02

C30/37 30 37 1,06

C35/45 35 45 1,09

C40/50 40 50 1,12

C45/55 45 55 1,14

C50/60 50 60 1,16

Concrete cylinder: Height 30cm, 15cm

diameter

Concrete cube: side length 15 cm

Concrete test specimen geometry

5.212

25f1f cube,ck

N,B

Limits: 25 N/mm² fck,cube(150) 60 N/mm²

fA,N : Influence of rebar spacing

Rebar diameter (mm) Anchorspacing,s [mm] 10 12 14 16 20 25 28 32 36

45 0,63 50 0,64 55 0,65 0,63 60 0,67 0,64 65 0,68 0,65 0,63 0,63 70 0,69 0,66 0,64 0,64 80 0,72 0,68 0,66 0,66 90 0,75 0,70 0,68 0,68 0,63

100 0,78 0,73 0,70 0,70 0,65 120 0,83 0,77 0,74 0,74 0,68 0,64 140 0,89 0,82 0,78 0,78 0,71 0,67 0,63 160 0,94 0,86 0,82 0,82 0,74 0,69 0,65 0,63 180 1,00 0,91 0,86 0,86 0,76 0,71 0,67 0,65 0,63200 0,95 0,90 0,90 0,79 0,74 0,69 0,67 0,64220 1,00 0,94 0,94 0,82 0,76 0,70 0,68 0,65250 1,00 1,00 0,87 0,80 0,73 0,71 0,67280 0,91 0,83 0,76 0,73 0,69310 0,96 0,87 0,79 0,76 0,72340 1,00 0,90 0,81 0,78 0,74390 0,96 0,86 0,83 0,77420 1,00 0,89 0,85 0,79450 0,92 0,88 0,81480 0,94 0,90 0,83540 1,00 0,95 0,88600 1,00 0,92660 0,96720 1,00

fR,N : Influence of edge distance

Rebar diameter (mm) Edgedistance,c [mm] 10 12 14 16 20 25 28 32 36

45 0,64 50 0,68 55 0,72 0,64 60 0,76 0,67 65 0,80 0,71 0,65 0,65 70 0,84 0,74 0,68 0,68 80 0,92 0,80 0,74 0,74 90 1,00 0,87 0,80 0,80 0,66

100 0,93 0,86 0,86 0,70 110 1,00 0,91 0,91 0,75 0,66 120 0,97 0,97 0,79 0,69 140 1,00 1,00 0,87 0,76 0,65 160 0,96 0,83 0,71 0,66 180 1,00 0,90 0,76 0,71 0,64210 1,00 0,84 0,78 0,70240 0,92 0,86 0,76270 1,00 0,93 0,82300 1,00 0,88330 0,94360 1,00

nomN,A

h4

s5,0f

Limits: smin s scr,N

smin = 0,5hnom

scr,N = 2,0hnom

nomN,R

h

c72,028,0f

Limits: cmin c ccr,N

cmin = 0,5hnom

ccr,N = 1,0hnom

Note: If more than 3 edges are smaller than ccr,N , consult your Hilti technical advisory service.

Page 79: Ancore Chimice Mecanice Pentru Sarcinimari

HVU adhesive with rebar

222 Issue 2005

NRd,s1) : Steel design tensile resistance

Rebar diameter [mm] 10 12 14 16 20 25 28 32 36

NRd,s1) [kN] rebar section 32.7 47.1 64.1 83.8 130.9 204.5 256.6 335.1 424.1

1) The design tensile resistance is calculated from the characteristic tensile resistance, NRk,s , by NRd,s= As fuk/ Ms,N, where the partial safety factor, Ms,N , for rebar sections of type BSt 500 is 1.32.

NRd : System design tensile resistance

NRd = lower of NRd,c and NRd,s

Combined loading: Only if tensile load and shear load applied (See page 31 and section 4 “Examples").

Detailed design method – Hilti CC

SHEAR

The design shear resistance of a singleanchor is the lower of

VRd,c : concrete edge resistance

VRd,s : steel resistance

VRd,c: Concrete edge design resistance

The lowest concrete edge resistance must be calculated. All near edges must be checked (not only the edge in the direction of shear). The direction of shear is accounted for by the factor f ,V.

V,V,ARV,B0

c,Rdc,Rd fffVV

V0Rd,c: Concrete edge design resistance

concrete compressive strength, fck,cube(150) = 25 N/mm2

at a minimum edge distance minc

Rebar diameter [mm] 10 12 14 16 20 25 28 32 36

VoRd,c

1) [kN] 3.6 5.0 7.1 7.3 12.5 18.8 30.2 37.7 52.1

cmin [mm] Min. edge distance 45 55 65 65 85 105 135 150 180 1) The shear design resistance is calculated from the characteristic shear resistance, Vo

Rk,c , by VoRd,c= Vo

Rk,c/ Mc,V, where the partial safety factor, Mc,V , is 1.5.

(The Hilti CC method is a simplified version of ETAG Annex C.)

V

cs

rec,c/sc >1.5c2

c >1.5c2

h>1.5c

Page 80: Ancore Chimice Mecanice Pentru Sarcinimari

HVU adhesive with rebar

Issue 2005 223

3

fB,V: Influence of concrete strength

Concrete strength designation(ENV 206)

Cylinder compressive strength,

fck,cyl [N/mm²]

Cube compressive strength,

fck,cube [N/mm²] fB,V

C20/25 20 25 1

C25/30 25 30 1.1

C30/37 30 37 1.22

C35/45 35 45 1.34

C40/50 40 50 1.41

C45/55 45 55 1.48

C50/60 50 60 1.55

Concrete cylinder: Height 30cm, 15cm

diameter

Concrete cube: side length 15 cm

Concrete test specimen geometry

fAR,V: Influence of edge distance and spacing

c/cminfAR,V 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 3.2 3.4 3.6 3.8 4.0

Single anchor with edge influence, 1.00 1.31 1.66 2.02 2.41 2.83 3.26 3.72 4.19 4.69 5.20 5.72 6.27 6.83 7.41 8.00

s/cmin 1.0 0.67 0.84 1.03 1.22 1.43 1.65 1.88 2.12 2.36 2.62 2.89 3.16 3.44 3.73 4.03 4.331.5 0.75 0.93 1.12 1.33 1.54 1.77 2.00 2.25 2.50 2.76 3.03 3.31 3.60 3.89 4.19 4.502.0 0.83 1.02 1.22 1.43 1.65 1.89 2.13 2.38 2.63 2.90 3.18 3.46 3.75 4.05 4.35 4.672.5 0.92 1.11 1.32 1.54 1.77 2.00 2.25 2.50 2.77 3.04 3.32 3.61 3.90 4.21 4.52 4.833.0 1.00 1.20 1.42 1.64 1.88 2.12 2.37 2.63 2.90 3.18 3.46 3.76 4.06 4.36 4.68 5.003.5 1.30 1.52 1.75 1.99 2.24 2.50 2.76 3.04 3.32 3.61 3.91 4.21 4.52 4.84 5.174.0 1.62 1.86 2.10 2.36 2.62 2.89 3.17 3.46 3.75 4.05 4.36 4.68 5.00 5.334.5 1.96 2.21 2.47 2.74 3.02 3.31 3.60 3.90 4.20 4.52 4.84 5.17 5.505.0 2.33 2.59 2.87 3.15 3.44 3.74 4.04 4.35 4.67 5.00 5.33 5.675.5 2.71 2.99 3.28 3.57 3.88 4.19 4.50 4.82 5.15 5.49 5.836.0 2.83 3.11 3.41 3.71 4.02 4.33 4.65 4.98 5.31 5.65 6.006.5 3.24 3.54 3.84 4.16 4.47 4.80 5.13 5.47 5.82 6.177.0 3.67 3.98 4.29 4.62 4.95 5.29 5.63 5.98 6.337.5 4.11 4.43 4.76 5.10 5.44 5.79 6.14 6.508.0 4.57 4.91 5.25 5.59 5.95 6.30 6.678.5 5.05 5.40 5.75 6.10 6.47 6.839.0 5.20 5.55 5.90 6.26 6.63 7.009.5 5.69 6.05 6.42 6.79 7.17

10.0 6.21 6.58 6.95 7.3310.5 6.74 7.12 7.5011.0 7.28 7.6711.5 7.8312.0 8.00

25

ff cube,ck

V,B

Limits: 25 N/mm2 fck,cube(150) 60 N/mm2

These results are for a two-anchor fastening. For fastenings with more than two anchors, use the general formulae for n anchors.

Page 81: Ancore Chimice Mecanice Pentru Sarcinimari

HVU adhesive with rebar

224 Issue 2005

ccs

ss

2,2

1

2

3

n-1sc2,1

h >1,5 c

Note: It is assumed that only the row of anchors closest to the free concrete edge carries the centric shear load.

fAR,V: Influence of edge distance and spacing

Formula for single-anchor fastening influenced only by edge

minminV,AR

c

c

c

cf

Formula for two-anchor fastening (edge plus 1 spacing) only valid for s < 3c

minminV,AR

c

c

c6

sc3f

General formula for n-anchor fastening (edge plus n-1 spacing) only valid where sn and sn-1 are each < 3c and c2 > 1.5c

minmin

1n21V,AR

c

c

cn3

s...ssc3f

f ,V : Influence of loading direction

Angle, ß [°] f ,V

0 to 55 1

60 1.1

70 1.2

80 1.5

90 to 180 2

VRd,s : Steel design shear resistance

Rebar diameter [mm] 10 12 14 16 20 25 28 32 36

VRd,s1) [kN] 17,3 24,9 33,9 44,3 69,3 108,0 135,3 176,7 224,0

1) The design shear resistance is calculated from VRd,s= (0,6 As fuk)/ Ms,V. The partial safety factor, Ms,V , for rebar sections of type BSt 500 is 1.5.

VRd : System design shear resistance

VRd = lower of VRd,c and VRd,s

Combined loading: Only if tensile load and shear load applied (See page 31 and section 4 “Examples”).

1fV,

ßsin5,0ßcos

1f

V,

2fV,

for 0° ß 55°

for 55° < ß 90°

for 90° < ß 180°

Formulae:

V ... applied shear force

resultstabulatedbelow

Page 82: Ancore Chimice Mecanice Pentru Sarcinimari

HVU adhesive with HAS rod

200 Issue 2005

Concrete Capacity Method

Design resistance, Rd [kN]: concrete, fck,cube = 25 N/mm2

Anchor size M8 M10 M12 M16 M20 M24 M27 M30 M33 M36 M39

Tensile, NRd 10.9 16.6 23.8 34.7 62.9 90.6 110.9 145.6 171.0 203.3 232.9 Shear, VRd 7.9 12.6 18.3 34.6 54.0 77.8 164.0 199.3 248.4 291.5 350.6

Recommended load, Lrec [kN]: concrete, fck,cube = 25 N/mm2

Anchor size M8 M10 M12 M16 M20 M24 M27 M30 M33 M36 M39

Tensile, NRec 7.8 11.8 17.0 24.8 44.9 64.7 79.2 104.0 122.1 145.2 166.4 Shear, VRec 5.6 9.0 13.1 24.7 38.6 55.6 117.1 142.4 177.4 208.2 250.4

Features:

- foil capsule vs. glass

- flexible for inserting into crooked / irregular holes

- pre-setting / through-setting

- specials lengths available on request

- test reports: fire, dynamic (fatigue, shock, seismic), water tightness

Material:

HVU:- urethane methacrylate resin – styrene free, hardener, quartz sand or corundum, foil tube

HAS, HAS-E: - grade 5.8 and 8.8, ISO 898 T1, galvanised to min. 5 microns

HAS-R / -ER: - stainless steel; A4-70; 1.4401, 1.4404, 1.4571

HAS-HCR: - stainless steel; 1.4529

HVU capsule

HAS, HAS-R, HAS-HCR

HAS-E, HAS-E-R

Concrete Small edge distance /spacing

Fatigue Seismic

A4316

HCRhighMo

Corrosionresistance

Highcorrosionresistance

Fire resistance Hilti Anchor programme

Basic loading data (for a single anchor): HVU capsule with HAS, HAS-E

All data on this page applies to For detailed design method, see pages 204 – 208. concrete: See table below. correct setting (See setting operations page 203) no edge distance and spacing influence

steel failure: steel grade 5.8 for M8 – M24 sizes and steel grade 8.8 for M27 – M39

Mean ultimate resistance, Ru,m [kN]: concrete C20/25

Anchor size M8 M10 M12 M16 M20 M24 M27 M30 M33 M36 M39

Tensile, NRu,m 17.7 28.2 41.1 77.9 121.7 175.2 320.1 305.1 498.6 534.0 621.6 Shear, VRu,m 10.7 17.0 24.7 46.7 72.9 105.0 221.4 269.1 335.3 393.5 473.3

Characteristic resistance, Rk [kN]: concrete C20/25

Anchor size M8 M10 M12 M16 M20 M24 M27 M30 M33 M36 M39

Tensile, NRk 16.4 26.1 38.1 72.2 112.7 162.0 182.4 228.0 440.9 494.0 503.2 Shear, VRk 9.9 15.8 22.9 43.2 67.5 97.3 205.0 249.1 310.5 364.4 438.3

Following values according to the

non-cracked concrete

Page 83: Ancore Chimice Mecanice Pentru Sarcinimari

HVU adhesive with HAS rod

Issue 2005 201

3

Basic loading data (for a single anchor): HVU capsule with HAS-R, HAS-E-R, HAS-HCR

All data on this section applies to For detailed design method, see pages 204 – 208. concrete: See table below. correct setting (See setting operations page 203) no edge distance and spacing influence

steel failure: steel grade A4-70 for M8 – M24; for A4 grade, fuk changes for the sizes M27 to M39 from 700 N/mm2 to 500 N/mm2.

Mean ultimate resistance, Ru,m [kN]: concrete C20/25

Anchor size M8 M10 M12 M16 M20 M24 M27 M30 M33 M36 M39

Tensile, NRu,m 24.8 39.6 57.8 109.1 170.3 244.4 230.7 280.2 349.4 410.1 493.0

Shear, VRu,m 14.8 23.8 34.5 65.4 102.1 146.9 138.5 168.3 209.7 246.0 295.9

Characteristic resistance, Rk [kN]: concrete C20/25

Anchor size M8 M10 M12 M16 M20 M24 M27 M30 M33 M36 M39

Tensile, NRk 23.0 36.7 53.5 101.0 157.6 226.3 213.6 259.4 323.5 379.7 456.5

Shear, VRk 13.7 22.0 32.0 60.5 94.5 136.0 128.2 155.8 194.2 227.8 274.0

Following values according to the

Concrete Capacity Method

Design resistance, Rd [kN]: concrete, fck,cube = 25 N/mm2

Anchor size M8 M10 M12 M16 M20 M24 M27 M30 M33 M36 M39

Tensile, NRd 12.3 16.6 23.8 34.7 62.9 90.6 89.0 108.1 134.8 158.2 190.2 Shear, VRd 8.8 14.1 20.5 38.8 60.6 87.2 64.1 77.9 97.1 113.9 137.0

Recommended load, Lrec [kN]: concrete, fck,cube = 25 N/mm2

Anchor size M8 M10 M12 M16 M20 M24 M27 M30 M33 M36 M39

Tensile, NRec 8.8 11.8 17.0 24.8 44.9 64.7 63.6 77.2 96.3 113.0 135.9 Shear, VRec 6.3 10.1 14.6 27.7 43.3 62.3 45.8 55.6 69.4 81.3 97.9

non-cracked concrete

Page 84: Ancore Chimice Mecanice Pentru Sarcinimari

HVU adhesive with HAS rod

202 Issue 2005

d0

df

h1

h

t fix

min

Setting details

Anchor size M8 M10 M12 M16 M20 M24 M27 M30 M33 M36 M39

Foil capsule HVU M8x80 M10x90 M12x110 M16x125 M20x170 M24x210 M27x240 M30x270 M33x300 M36x330 M39x360

Anchor rod1) HAS /-E/-R/-ER/-HCR M8x80/

14M10x90/

21M12x110/

28M16x125/

38M20x170/

48M24x210/

54M27x240/

60M30x270/

70M33x300/

80M36x330/

90M39x360/

100

d0 Drill bit diameter [mm] 10 12 14 18 24 28 30 35 37 40 42

h1=hnom

Hole depth =

Embedment depth [mm] 80 90 110 125 170 210 240 270 300 330 360

h (min) Min. thickness of base material

[mm] 110 120 140 170 220 270 300 340 380 410 450

tfix (max) Max. fixture thickness

[mm] 14 21 28 38 48 54 60 70 80 90 100

dfClearancehole

rec. [mm] max. [mm]

911

1213

1415

1819

2225

2629

3031

3336

3638

3941

4243

Tinst Tightening torque [Nm] 15 30 50 100 160 240 270 300 1200 1500 1800

TE-CX- 10/22 12/22 14/22 - - - - - - - - Drill bit

TE-T- - - - 18/32 24/32 28/52 30/57 - - - -

Rec. diamond drilling machine DD EC-1 DD 100 // DD 160 E

1) The values for the maximum fixture thickness are only valid for the HAS anchor rods given in this table. If other HAS rods are used, these values will change. (Example: HAS M12x110/128; tfix = 128 mm)

Temperature1) when setting:

Min. time to wait before removing SCREWED-ON

setting tool, trel

Curing timebefore anchor can be fully loaded,

tcure

20°C and above 10°C to 20°C 0°C to 10°C -5°C to 0°C

8 min. 20 min. 30 min. 60 min.

20 min. 30 min. 60 min. 5 hours

1) If the temperature is less than –5°C, contact your Hilti technical service.

Installation equipment

Rotary hammer (TE1, TE 2, TE5, TE6, TE6A, TE15, TE15-C, TE18-M, TE 35, TE 55 or TE 76) or a diamond drilling machine, a drill bit, a TE-C HEX, TE-C-E TE-Y-E setting tool and a blow-out pump.

Page 85: Ancore Chimice Mecanice Pentru Sarcinimari

HVU adhesive with HAS rod

Issue 2005 203

3

Setting operations

1 2 3HVU

5 HAS4

Drill hole. Blow out dust and

fragments.Insert HVU capsule. Drive in anchor.

5 trel 6 tcure7

Tinst

Allow gel time to pass. Wait for curing. Apply tightening

torque.

Anchor geometry and mechanical properties

dp

lp l

dw

Sw

Anchor size M8 M10 M12 M16 M20 M24 M27 M30 M33 M36 M39

Foil capsule HVU M8x80 M10x90 M12x110 M16x125 M20x170 M24x210 M27x240 M30x270 M33x300 M36x330 M39x360

lp [mm] HVU capsule length 110 110 127 140 170 200 225 260 290 320 350

dp [mm] HVU capsule diameter 9.3 10.7 13.1 17.1 22.0 25.7 26.8 31.5 31.5 32.0 35.0

Anchor rod HAS M8x80/ 14

M10x90/21

M12x110/28

M16x125/38

M20x170/48

M24x210/54

M27x240/ 60

M30x270/ 70

M33x300/80

M36x330/90

M39x360/100

l [mm] Anchor length 110 130 160 190 240 290 340 380 420 460 510

As [mm2] Stressed cross-section 32.8 52.3 76.2 144 225 324 427 519 647 759 913

HAS 5.8 500 500 500 500 500 500 - - - - -

HAS 8.8 - - - - - - 800 800 800 800 800

HAS-R

fuk [N/mm2] Nominal tensile strength

-HCR700 700 700 700 700 700 500 500 500 500 500

HAS 5.8 400 400 400 400 400 400 - - - - -

HAS 8.8 - - - - - - 640 640 640 640 640

HAS-R fyk [N/mm2] Yield strength

-HCR450 450 450 450 450 450 250 250 250 250 250

W [mm3] Moment of resistance 26.5 53.3 93.9 244 477 824 1245 1668 2322 2951 3860

HAS 5.8 12.7 25.6 45.1 117.1 228.8 395.3 - - - - -

HAS 8.8 - - - - - - 956.1 1280.8 1783.5 2266.5 2987.8

HAS-R MRd,s [Nm]

Design bending resistance1)

-HCR14.3 28.7 50.6 131.4 256.7 443.5 478.8 641.5 893.0 1134.9 1484.5

Sw [mm] Width across flats 13 17 19 24 30 36 41 46 50 55 59

dw [mm] Washer diameter 16 20 24 30 37 44 50 56 60 66 72

1) The design bending resistance of the anchor rod is calculated from MRd,s = (1.2 · W · fuk)/ Ms,b , where the partial safety factor, Ms,b , for grade 5.8 and 8.8 rods is 1.25 and for 1.56 for A4-70 and HCR. The final safety check is then MSk · F MRd,s

dp

lp

HVU M..HVU M.. HVU M..

Page 86: Ancore Chimice Mecanice Pentru Sarcinimari

HVU adhesive with HAS rod

204 Issue 2005

Detailed design method - Hilti CC

Caution: In view of the high loads transferable with HVU, it must be verified by the user that the load acting on the concrete structure, including the loads introduced by the anchor fastening, do not cause failure, e.g. cracking, of the concrete structure.

TENSION

The design tensile resistance of a single anchoris the lower of

NRd,c : concrete cone/pull-out resistance

NRd,s : steel resistance

NRd,c: Concrete cone/pull-out resistance

N,RN,ATN,Bo

c,Rdc,Rd ffffNN

N0Rd,c : Concrete cone/pull-out design resistance

Concrete compressive strength, fck,cube(150) = 25 N/mm2

Anchor size M8 M10 M12 M16 M20 M24 M27 M30 M33 M36 M39

N0Rd,c

1) [kN] 12.4 16.6 23.8 34.7 62.9 90.6 110.9 145.6 171.0 203.3 232.9

hnom [mm] Nominal anchorage depth 80 90 110 125 170 210 240 270 300 330 3601) The design tensile resistance is calculated from the characteristic tensile resistance, N°Rk,c , by N°Rd,c = N°Rk,c/ Mc,N, where the

partial safety, Mc,N , factor is 1.8.

fB,N : Influence of concrete strength

Designation of grade of concrete

(ENV 206)

Cylinder compressive

strength,

fck,cyl [N/mm²]

Cube compressive

strength,

fck,cube [N/mm²] fB,N

C16/20 16 20 0.94

C20/25 20 25 1

C25/30 25 30 1.05

C30/37 30 37 1.12

C35/45 35 45 1.20

C40/50 40 50 1.25

C45/55 45 55 1.30

C50/60 50 60 1.35

Concrete cylinder:

height 30cm, 15cm

diameter

Concrete cube:

side length 15cm

Concrete test specimen geometry

(The Hilti CC method is a simplified version of ETAG Annex C.)

N

cs

h

rec,c/s

80

25f1f

ck,cubeNB,

for fck,cube= 20N/mm²

100

25f1f cubeck,

NB,

Limits: 25 N/mm² fck,cube 60 N/mm²

Page 87: Ancore Chimice Mecanice Pentru Sarcinimari

HVU adhesive with HAS rod

Issue 2005 205

3

fT :Influence of anchorage depth

fA,N : Influence of anchor spacing

Anchor Anchor size spacing,s [mm] M8 M10 M12 M16 M20 M24 M27 M30 M33 M36 M39

40 0,63 45 0,64 0,63 50 0,66 0,64 55 0,67 0,65 0,63 60 0,69 0,67 0,64 65 0,70 0,68 0,65 0,63 70 0,72 0,69 0,66 0,64 80 0,75 0,72 0,68 0,66 90 0,78 0,75 0,70 0,68 0,63

100 0,81 0,78 0,73 0,70 0,65 120 0,88 0,83 0,77 0,74 0,68 0,64 0,63 140 0,94 0,89 0,82 0,78 0,71 0,67 0,65 0,63 160 1,00 0,94 0,86 0,82 0,74 0,69 0,67 0,65 0,63 180 1,00 0,91 0,86 0,76 0,71 0,69 0,67 0,65 0,64 0,63 200 0,95 0,90 0,79 0,74 0,71 0,69 0,67 0,65 0,64 220 1,00 0,94 0,82 0,76 0,73 0,70 0,68 0,67 0,65 250 1,00 0,87 0,80 0,76 0,73 0,71 0,69 0,67 280 0,91 0,83 0,79 0,76 0,73 0,71 0,69 310 0,96 0,87 0,82 0,79 0,76 0,73 0,72 340 1,00 0,90 0,85 0,81 0,78 0,76 0,74 390 0,96 0,91 0,86 0,83 0,80 0,77 420 1,00 0,94 0,89 0,85 0,82 0,79 450 0,97 0,92 0,88 0,84 0,81 480 1,00 0,94 0,90 0,86 0,83 540 1,00 0,95 0,91 0,88 600 1,00 0,95 0,92 660 1,00 0,96 720 1,00

fR,N: Influence of edge distance

Edge Anchor size distance,c [mm] M8 M10 M12 M16 M20 M24 M27 M30 M33 M36 M39

40 0,64 45 0,69 0,64 50 0,73 0,68 55 0,78 0,72 0,64 60 0,82 0,76 0,67 65 0,87 0,80 0,71 0,65 70 0,91 0,84 0,74 0,68 80 1,00 0,92 0,80 0,74 90 1,00 0,87 0,80 0,66

100 0,93 0,86 0,70 110 1,00 0,91 0,75 0,66 120 0,97 0,79 0,69 0,64 140 1,00 0,87 0,76 0,70 0,65 160 0,96 0,83 0,76 0,71 0,66 180 1,00 0,90 0,82 0,76 0,71 0,67 0,64 210 1,00 0,91 0,84 0,78 0,74 0,70 240 1,00 0,92 0,86 0,80 0,76 270 1,00 0,93 0,87 0,82 300 1,00 0,93 0,88 330 1,00 0,94 360 1,00

nom

actT

h

hf Limits to actual anchorage depth hact: hnom hact 2.0 hnom

nomN,R

h

c72,028,0f

Limits: cmin c ccr,N

cmin = 0,5 hnom

ccr,N = 1,0 hnom

Note: If more than 3 edges are smaller than ccr,N , consult your Hilti technical advisory service.

nomN,A

h4

s5,0f

Limits: smin s scr,N

smin=0,5 hnom

scr,N=2,0 hnom

Page 88: Ancore Chimice Mecanice Pentru Sarcinimari

HVU adhesive with HAS rod

206 Issue 2005

NRd,s1) : Steel design tensile resistance

Anchor size M8 M10 M12 M16 M20 M24 M27 M30 M33 M36 M39

HAS grade 5.8 2) [kN] 10,9 17,4 25,4 48,1 75,1 108,1 142,3 173,0 215,7 253,1 304,3

HAS grade 8.8 2) [kN] 17,5 27,9 40,7 78,9 120,1 172,9 227,8 276,8 345,2 404,9 486,9

HAS-R,HAS-HCR2)3) [kN] 12,3 19,6 28,6 54,0 84,3 121,0 89,0 108,1 134,8 158,2 190,2

1) The design tensile resistance is calculated from the characteristic tensile resistance, NRk,s , using NRd,s= As · fuk/ Ms,N, where the partial safety factor, Ms,N , for grade 5.8 and 8.8 is 1.5; 1.87 for grades A4-70 and HCR of the M8 to M24 sizes and 2.4 for grades A4-70 and HCR in the sizes M27 – M39.

2) Data given in italics applies to non-standard rods. 3) Note: The values for the nominal tensile steel strength, fuk, for grade A4 change for the M27 to M39 sizes from 700 N/mm² to 500 N/mm²

and the yield strength, fyk, changes for the M27 to M39 sizes from 450 N/mm² to 250 N/mm². The partial safety factor, Ms,N, changes with the steel strengths as stated in note 1) above.

NRd : System design tensile resistance

NRd = lower of NRd,c and NRd,s

Combined loading: Only if tensile load and shear load applied (See page 31 and section 4 “Examples”).

Detailed design method – Hilti CC

SHEAR

The design shear resistance of a single anchor is the lower of

VRd,c : concrete edge resistance

VRd,s : steel resistance Note: If the conditions for h and c2 are not met, consult your Hilti technical advisory service.

VRd,c: Concrete edge design resistance

The lowest concrete edge resistance must be calculated. All near edges must be checked, (not only the edge in the direction of shear). The direction of shear is accounted for by the factor f ,V.

V,VAR,VB,0

cRd,cRd, fffVV

V

cs

rec,c/sc >1.5c2

c >1.5c2

h>1.5c

(The Hilti CC method is a simplified version of ETAG Annex C.)

Page 89: Ancore Chimice Mecanice Pentru Sarcinimari

HVU adhesive with HAS rod

Issue 2005 207

3

V0Rd,c : Concrete edge design resistance

Concrete compressive strength, fck,cube(150) = 25 N/mm2

at a minimum edge distance minc

Anchor size M8 M10 M12 M16 M20 M24 M27 M30 M33 M36 M39

VoRd,c

1) [kN] 2.6 3.4 5.0 6.7 12.4 18.5 23.6 30.2 36.8 44.3 52.1

cmin [mm] min. edge distance 40 45 55 65 85 105 120 135 150 165 180 1) The design shear resistance is calculated from the characteristic shear resistance, Vo

Rk,c, using VoRd,c= Vo

Rk,c/ Mc,V, where the partial safety factor, Mc,V , is 1.5.

fB,V: Influence of concrete strength

Concrete strength designation(ENV 206)

Cylinder compressive strength,

fck,cyl [N/mm²]

Cube compressive strength,

fck,cube [N/mm²] fB,N

C16/20 16 20 0.89

C20/25 20 25 1

C25/30 25 30 1.1

C30/37 30 37 1.22

C35/45 35 45 1.34

C40/50 40 50 1.41

C45/55 45 55 1.48

C50/60 50 60 1.55

Concrete cylinder:

height 30cm, 15cm

diameter

Concrete cube:

side length 15cm

Concrete test specimen geometry

fAR,V: Influence of spacing and edge distance

Formula for single-anchor fastening influenced only by edge

minminV,AR

c

c

c

cf

Formula for two-anchor fastening (edge plus 1 spacing) only valid for s < 3c

minminV,AR c

c

c6

sc3f

General formula for n-anchor fastening (edge plus n-1 spacing) only valid where s1 and sn-1 are each < 3c and c2 > 1.5c

minmin

1n21V,AR c

c

nc3

s...ssc3f

25

cubeck,

VB,

ff

Limits: 20 N/mm2 fck,cube 60 N/mm2

ccs

ss

2,2

1

2

3

n-1sc2,1

h >1,5 c

Note: It is assumed that only the row of anchors closest to the free concrete edge carries the centric shear load.

results tabulatedbelow

Page 90: Ancore Chimice Mecanice Pentru Sarcinimari

HVU adhesive with HAS rod

208 Issue 2005

fAR,V : Influence of edge distance and spacing

fAR,V c/cmin

1,0 1,2 1,4 1,6 1,8 2,0 2,2 2,4 2,6 2,8 3,0 3,2 3,4 3,6 3,8 4,0

Single anchor with edge influence, 1,00 1,31 1,66 2,02 2,41 2,83 3,26 3,72 4,19 4,69 5,20 5,72 6,27 6,83 7,41 8,00

s/cmin 1,0 0,67 0,84 1,03 1,22 1,43 1,65 1,88 2,12 2,36 2,62 2,89 3,16 3,44 3,73 4,03 4,331,5 0,75 0,93 1,12 1,33 1,54 1,77 2,00 2,25 2,50 2,76 3,03 3,31 3,60 3,89 4,19 4,502,0 0,83 1,02 1,22 1,43 1,65 1,89 2,13 2,38 2,63 2,90 3,18 3,46 3,75 4,05 4,35 4,672,5 0,92 1,11 1,32 1,54 1,77 2,00 2,25 2,50 2,77 3,04 3,32 3,61 3,90 4,21 4,52 4,833,0 1,00 1,20 1,42 1,64 1,88 2,12 2,37 2,63 2,90 3,18 3,46 3,76 4,06 4,36 4,68 5,003,5 1,30 1,52 1,75 1,99 2,24 2,50 2,76 3,04 3,32 3,61 3,91 4,21 4,52 4,84 5,174,0 1,62 1,86 2,10 2,36 2,62 2,89 3,17 3,46 3,75 4,05 4,36 4,68 5,00 5,334,5 1,96 2,21 2,47 2,74 3,02 3,31 3,60 3,90 4,20 4,52 4,84 5,17 5,505,0 2,33 2,59 2,87 3,15 3,44 3,74 4,04 4,35 4,67 5,00 5,33 5,675,5 2,71 2,99 3,28 3,57 3,88 4,19 4,50 4,82 5,15 5,49 5,836,0 2,83 3,11 3,41 3,71 4,02 4,33 4,65 4,98 5,31 5,65 6,006,5 3,24 3,54 3,84 4,16 4,47 4,80 5,13 5,47 5,82 6,177,0 3,67 3,98 4,29 4,62 4,95 5,29 5,63 5,98 6,337,5 4,11 4,43 4,76 5,10 5,44 5,79 6,14 6,508,0 4,57 4,91 5,25 5,59 5,95 6,30 6,678,5 5,05 5,40 5,75 6,10 6,47 6,839,0 5,20 5,55 5,90 6,26 6,63 7,009,5 5,69 6,05 6,42 6,79 7,17

10,0 6,21 6,58 6,95 7,3310,5 6,74 7,12 7,5011,0 7,28 7,6711,5 7,8312,0 8,00

f ,V : Influence of shear loading direction

Angle, [°] f ,V

0 to 55 1

60 1.1

70 1.2

80 1.5

90 to 180 2

VRd,s1) : Steel design shear resistance

Anchor size M8 M10 M12 M16 M20 M24 M27 M30 M33 M36 M39

HAS grade 5.8 2) [kN] 7,9 12,6 18,3 34,6 54,0 77,8 102,5 124,6 155,3 182,2 219,1

HAS grade 8.8 2) [kN] 12,6 20,1 29,3 55,3 86,4 124,4 164,0 199,3 248,4 291,5 350,6

HAS-R, HAS-HCR2) 3) [kN] 8.8 14.1 20.5 38.8 60.6 87.2 64.1 77.9 97.1 113.9 137

1) The design shear resistance is calculated using VRd,s= (0,6 As fuk)/ Ms,V. The values for the stressed cross-section, As , and the nominal tensile strength of steel, fuk, are given in the table ”Anchor mechanical properties and geometry“. The partial safety factor, Ms,V , is 1.25 for grades 5.8 and 8.8; 1.56 for grade sA4-70 and HCR in the sizes M8 to M24, and 2.0 for grade A4-70 in the sizes M27 to M39.

2) Data given in italics applies to non-standard rods. 3) Note: The values for the nominal tensile strength of steel, fuk, for grade A4-70 change for the M27 to M39 sizes from 700 N/mm² to 500

N/mm² and the yield strength, fyk , changes for the M27 to M39 sizes from 450N/mm2 to 250N/mm2. The partial safety factor, Ms,V , changes the steel strengths as stated in note 1) above.

VRd : System design shear resistance

VRd = lower of VRd,c and VRd,s

Combined loading: Only if tensile load and shear load applied (See page 31 and section 4 “Examples”).

V ... applied shear force1f V,

sin5.0cos

1f V,

2f V,

for 0° 55°

for 55° < 90°

for 90° < 180°

Formulae:

These results are for a two-anchor fastening. For fastenings with more than two anchors, use the general formulae for n anchors.

Page 91: Ancore Chimice Mecanice Pentru Sarcinimari

HVU adhesive with HIS-N/HIS-RN sleeve

Issue 2005 209

Features:

- anchor fastenings flush with surface

- foil capsule vs. glass

- no expansion force in base material

- high loading capacity

- small edge distance and spacing

- complete system consisting of robust foil capsule, internally threaded sleeve and setting tool

Material:

HIS-N: - carbon steel galvanised to 5 microns

HIS-RN - stainless steel, A4-70: 1.4401

HVU capsule: - urethane methacrylate resin, styrene free,

hardener, quartz sand or corundum, foil tube

HVU capsule

HIS-N, HIS-RN internally threaded sleeves

A4316

Concrete Small edge distance/ spacing

Fireresistance

Corrosion resistance

Hilti Anchor programme

Basic loading data (for a single anchor): HIS-N

All data on this page applies to For detailed design method, see pages 212 – 217. concrete: See table below. correct setting (See setting operations page 211) no edge distance and spacing influence tensile values are for HIS-N (derived using grade 12.9 rods)

shear (steel failure): rod / bolt of steel grade 5.8

Mean ultimate resistance, Ru,m [kN]: concrete C20/25

Anchor size M8 M10 M12 M16 M20

Tensile, NRu,m 37.2 85.1 102.4 161.3 210.0

Shear, VRu,m 11.9 18.8 27.3 50.9 79.4

Characteristic resistance, Rk [kN]: concrete C20/25

Anchor size M8 M10 M12 M16 M20

Tensile, NRk 35.6 81.6 66.9 150.3 174.3

Shear, VRk 11.0 17.4 25.3 47.1 73.5

Following values according to the

Concrete Capacity Method

Design resistance, Rd [kN]: concrete, fck,cube = 25 N/mm2

Anchor size M8 M10 M12 M16 M20

Tensile, NRd 12.2 19.3 28.1 52.3 81.7 Shear, VRd 8.8 13.9 20.2 37.7 58.8

Recommended load, Lrec [kN]: concrete, fck,cube = 25 N/mm2

Anchor size M8 M10 M12 M16 M20

Tensile, NRec 8.7 13.8 20.1 37.4 58.6 Shear, VRec 6.3 9.9 14.5 26.9 42.0

non-cracked concrete

3

Page 92: Ancore Chimice Mecanice Pentru Sarcinimari

HVU adhesive with HIS-N/HIS-RN sleeve

210 Issue 2005

Basic loading data (for a single anchor): HIS-RN

All data on this section applies to For detailed design method, see pages 212 – 217. concrete: See table below. correct setting (See setting operations page 211) no edge distance and spacing influence tensile values are for HIS-RN (derived using grade 12.9 rods)

shear (steel failure): rod / bolt of steel grade A4-70

Mean ultimate resistance, Ru,m [kN]: concrete C20/25

Anchor size M8 M10 M12 M16 M20

Tensile, NRu,m 40.5 85.1 102.4 161.3 173.1

Shear, VRu,m 16.6 26.3 38.2 71.2 111.1

Characteristic resistance, Rk [kN]: concrete C20/25

Anchor size M8 M10 M12 M16 M20

Tensile, NRk 37.5 81.6 66.9 150.3 160.3

Shear, VRk 15.4 24.4 35.4 65.9 102.9

Following values according to the

Concrete Capacity Method

Design resistance, Rd [kN]: concrete, fck,cube = 25 N/mm2

Anchor size M8 M10 M12 M16 M20

Tensile, NRd 13.7 21.7 31.6 58.8 91.7 Shear, VRd 9.9 15.6 22.7 42.3 66.0

Recommended load, Lrec [kN]: concrete, fck,cube = 25 N/mm2

Anchor size M8 M10 M12 M16 M20

Tensile, NRec 9.8 15.5 22.5 42.0 65.5 Shear, VRec 7.1 11.1 16.2 30.2 47.1

Setting details

hs

dfd0

min

h1h

nomh

non-cracked concrete

Page 93: Ancore Chimice Mecanice Pentru Sarcinimari

HVU adhesive with HIS-N/HIS-RN sleeve

Issue 2005 211

3

Anchor size M8 M10 M12 M16 M20

Foil capsule HVU... M10x90 M12x110 M16x125 M20x170 M24x210

Sleeve HIS-N ..., HIS-RN ... M8x90 M10x110 M12x125 M16x170 M20x205

d0 [mm] Drill bit diameter 14 18 22 28 32

h1 [mm] Hole depth 90 110 125 170 205

hmin [mm] Min. thickness of base material 120 150 170 230 280

hs [mm] Thread engagement min length max

820

1025

1230

1640

2050

df [mm] Rec. clearance hole 9 12 14 18 22

Tinst [Nm] Tightening torque HIS-N HIS-RN

1512

2823

5040

8570

170130

Drill bit TE-CX- 14/22 - - - -

Drill bit TE-T- - 18/32 22/32 28/32 32/37

Temperature when setting:

Min. time to wait before removing SCREWED-ON

setting tool, trel

Curing time before anchor can be fully loaded,

tcure

20°C and above 10°C to 20°C 0°C to 10°C -5°C to 0°C

8 min. 20 min. 30 min. 1 hour

20 min. 30 min. 1 hour 5 hours

Installation equipment

Rotary hammer (TE5, TE6, TE6A, TE15, TE15-C, TE18-M, TE 55 or TE 76), a drill bit, a setting tool, a TE adapter (TE-C-HIS, TE-F-Y-HIS) with HIS-S - M8 - M20 and a blow-out pump.

Setting operations

1 2 3HVU

54 HIS-N

Drill hole. Blow out dust and

fragments.Insert HVU capsule. Drive in anchor.

5 trel 6 tcure7

Tinst

Allow rel time to pass. Wait for curing. Apply tightening torque.

Page 94: Ancore Chimice Mecanice Pentru Sarcinimari

HVU adhesive with HIS-N/HIS-RN sleeve

212 Issue 2005

Anchor geometry and mechanical properties

Anchor size M8 M10 M12 M16 M20

Capsule HVU ... M10x90 M12x110 M16x125 M20x170 M24x210 lp [mm] Capsule length 110 127 140 170 200 dp [mm] Capsule diameter 10,7 13,1 17,1 22 25,7

Element HIS-N ..., HIS-RN ... M8x90 M10x110 M12x125 M16x170 M20x210

l [mm] Sleeve length 90 110 125 170 210

d [mm] Sleeve outside diameter

12,5 16,5 20,5 25,4 27,6

As [mm²] Stressed cross-section Sleeve

Bolt53,636,6

11058,0

17084,3

255157

229245

fuk [N/mm²]Nominal tensile strength

HIS-NHIS-RN

510700

510700

460700

460700

460700

fyk [N/mm²] Yield strength HIS-N

HIS-RN410350

410350

375350

375350

375350

W [mm³] Moment of resistance of bolt 31,2 62,3 109 277 375

MRd,s [Nm] Design bending resistance of bolt 1)

5.88.8

A2/A4

12,720,414,3

25,641,028,7

45,175,150,6

117,1187,4131,4

228,8366,1256,7

1) The design bending resistance of the bolt is calculated from MRd,s = (1,2 W fuk)/ ms,b, where the partial safety factor,

ms,b , for grade 5.8 and 8.8 bolts is 1.25 and 1.56 for A4-70 and A2-70. The final safety check is then MSk F MRd,s.

Detailed design method - Hilti CC

Caution: In view of the high loads transferable with the HVU, it must be verified by the user that the load acting on the concrete structure, including the loads introduced by the anchor fastening, do not cause failure, e.g. cracking, of the concrete structure.

TENSION

The design tensile resistance of a single anchoris the lower of

NRd,c : concrete cone/pull-out resistance

NRd,s : steel resistance of the bolt or sleeve

(The Hilti CC method is a simplified version of ETAG Annex C.)

dp

lp ll

ddp

lp

HVU M..HVU M.. HVU M..

N

cs

h

rec,c/s

Page 95: Ancore Chimice Mecanice Pentru Sarcinimari

HVU adhesive with HIS-N/HIS-RN sleeve

Issue 2005 213

3

NRd,c: Concrete cone/pull-out resistance

N,RN,AN,Bo

c,Rdc,Rd fffNN

N0Rd,c: Concrete cone/pull-out design resistance

Concrete compressive strength, fck,cube(150) = 25 N/mm2

Anchor size M8 M10 M12 M16 M20

NoRd,c [kN] 22.6 35.4 46.9 85.1 120.1

hnom [mm] Nominal anchorage depth 90 110 125 170 205 1) The design tensile resistance is calculated from the characteristic tensile resistance, No

Rk,c , by NoRd,c= No

Rk,c/ Mc,N, where the partial

safety factor, Mc,N , is 1.8.

fB,N: Influence of concrete strength

Concrete strength designation(ENV 206)

compressive cylinder strength,

fck,cyl [N/mm²]

compressive cube strength,

fck,cube [N/mm²] fB,N

C16/20 16 20 0.95

C20/25 20 25 1

C25/30 25 30 1.04

C30/37 30 37 1.10

C35/45 35 45 1.16

C40/50 40 50 1.20

C45/55 45 55 1.24

C50/60 50 60 1.28

Concrete cylinder:

height 30cm, 15cm

diameter

Concrete cube:

side length 15cm

Concrete test specimen geometry

fA,N: Influence of anchor spacing

Anchor size Spacing,s [mm] M8 M10 M12 M16 M20

45 0.63 50 0.64 55 0.65 0.63 60 0.67 0.64 65 0.68 0.65 0.63 70 0.69 0.66 0.64 80 0.72 0.68 0.66 90 0.75 0.70 0.68 0.63

100 0.78 0.73 0.70 0.65 110 0.81 0.75 0.72 0.66 0.63 120 0.83 0.77 0.74 0.68 0.65 140 0.89 0.82 0.78 0.71 0.67 160 0.94 0.86 0.82 0.74 0.70 180 1.00 0.91 0.86 0.76 0.72 200 0.95 0.90 0.79 0.74 220 1.00 0.94 0.82 0.77 250 1.00 0.87 0.80 280 0.91 0.84 310 0.96 0.88 340 1.00 0.91 390 0.98 410 1.00

nomN,A

h4

s5.0f

Limits: smin s scr,N

smin = 0,5hnom

scr,N = 2,0hnom

100

25f1 cubeck,

NB,f

for fck,cube(150) =20 N/mm²

125

25f1 cubeck,

NB,f

Limits: 25 N/mm² fck,cube(150) 60 N/mm²

Page 96: Ancore Chimice Mecanice Pentru Sarcinimari

HVU adhesive with HIS-N/HIS-RN sleeve

214 Issue 2005

fR,N: Influence of edge distance

Anchor size Edgedistance,c [mm] M8 M10 M12 M16 M20

45 0.64 50 0.68 55 0.72 0.64 60 0.76 0.67 65 0.80 0.71 0.65 70 0.84 0.74 0.68 80 0.92 0.80 0.74 90 1.00 0.87 0.80 0.66

100 0.93 0.86 0.70 110 1.00 0.91 0.75 0.67 120 0.97 0.79 0.70 140 1.00 0.87 0.77 160 0.96 0.84 180 1.00 0.91 210 1.00

NRd,s1): Steel design tensile resistance

Anchor size M8 M10 M12 M16 M20

NRdsleeve

,s [kN] Sleeve HIS-N

HIS-RN

18,2

15,6

37,4

32,1

52,1

49,6

78,2

74,4

70,2

66,8

NRd sbolt

, [kN] Bolt grade 5.8

grade 8.8grade A4-70

12,2

19,513,7

19,3

30,921,7

28,1

44,931,6

52,3

84,058,8

81,7

130,791,7

1) The design tensile resistance is calculated from the characteristic tensile resistance, NRk,s , by NRd,s= As fuk/ Ms,N, where the partial

safety factor, Ms,N , for the sleeve / bolts of grades 5.8 and 8.8 is 1.5 or 1.87 for grade A4-70 and 2.4 for the sleeve.

NRd : System design tensile resistance

NRd = lower of NRd,c, NRd,ssleeve or NRd,s

bolt

Combined loading: Only if tensile load and shear load applied (See page 31 and section 4 “Examples”).

nomN,R

h

c72.028.0f

Limits: cmin c ccr,N

cmin= 0,5 hnom

ccr,N= 1,0 hnom

Note: If more than 3 edges are smaller than ccr,N , consult your Hilti technical advisory service.

Page 97: Ancore Chimice Mecanice Pentru Sarcinimari

HVU adhesive with HIS-N/HIS-RN sleeve

Issue 2005 215

3

Detailed design method – Hilti CC

SHEAR

The design shear resistance of a single anchor is the lower of

VRd,c : concrete edge resistance

VRd,s : steel resistance of the bolt

VRd,c: Concrete edge design resistance

The lowest concrete edge resistance must be calculated. All near edges must be checked (not only the edge in the direction of shear). The direction of shear is accounted for by the factor f ,V.

VAR,V,VB,0

cRd,cRd, fffVV

V0Rd,c: Concrete edge design resistance

concrete compressive strength, fck,cube(150) = 25 N/mm2

at a minimum edge distance minc

Anchor size M8 M10 M12 M16 M20

V0Rd,c

1) [kN] 3.6 5.4 7.6 12.8 19.2

cmin [mm] Min. edge distance 45 55 65 85 105 1) The design shear resistance is calculated from the characteristic shear resistance, Vo

Rk,c , by VoRd,c= Vo

Rk,c/ Mc,V, where the partial safety factor, Mc,V , is 1.5.

fBV: Influence of concrete strength

Concrete strength designation(ENV 206)

Cylinder compressive strength,

fck,cyl [N/mm²]

Cube compressive strength,

fck,cube [N/mm²] fB,V

C16/20 16 20 0.89

C20/25 20 25 1

C25/30 25 30 1.1

C30/37 30 37 1.22

C35/45 35 45 1.34

C40/50 40 50 1.41

C45/55 45 55 1.48

C50/60 50 60 1.55

Concrete cylinder:

height 30cm, 15cm

diameter

Concrete cube:

side length 15cm

Concrete test specimen geometry

V

cs

rec,c/sc >1.5c2

c >1.5c2

h>1.5c

Note: If the conditions for h and c2 are not met, consult your Hilti technical advisory service.

25

ff cube,ck

V,B

Limits: 20 N/mm2 fck,cube(150) 60 N/mm2

(The Hilti CC method is a simplified version of ETAG Annex C.)

Page 98: Ancore Chimice Mecanice Pentru Sarcinimari

HVU adhesive with HIS-N/HIS-RN sleeve

216 Issue 2005

ccs

ss

2,2

1

2

3

n-1sc2,1

h >1,5 c

Note: It is assumed that only the row of anchors closest to the free concrete edge carries the centric shear load.

f ,V : Influence of loading direction

Angle, ß [°] f ,V

0 to 55 1

60 1.1

70 1.2

80 1.5

90 to 180 2

fAR,V: Formulae for edge distance and spacing influence

Formula for single-anchor fastening influenced only by edge

minminV,AR

c

c

c

cf

Formula for two-anchor fastening anchors (edge plus 1 spacing) only valid for s < 3c

minminV,AR

c

c

c6

sc3f

General formula for n-anchor fastening (edge plus n-1 spacing) only valid where s1 and sn-1 are each < 3c and c2 > 1.5c

minmin

1n21V,AR

c

c

cn3

s...ssc3f

fAR,V: Influence of edge distance and spacing

c/cminfAR,V 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 3.2 3.4 3.6 3.8 4.0

Single anchor with edge influence, 1.00 1.31 1.66 2.02 2.41 2.83 3.26 3.72 4.19 4.69 5.20 5.72 6.27 6.83 7.41 8.00

s/cmin 1.0 0.67 0.84 1.03 1.22 1.43 1.65 1.88 2.12 2.36 2.62 2.89 3.16 3.44 3.73 4.03 4.331.5 0.75 0.93 1.12 1.33 1.54 1.77 2.00 2.25 2.50 2.76 3.03 3.31 3.60 3.89 4.19 4.502.0 0.83 1.02 1.22 1.43 1.65 1.89 2.13 2.38 2.63 2.90 3.18 3.46 3.75 4.05 4.35 4.672.5 0.92 1.11 1.32 1.54 1.77 2.00 2.25 2.50 2.77 3.04 3.32 3.61 3.90 4.21 4.52 4.833.0 1.00 1.20 1.42 1.64 1.88 2.12 2.37 2.63 2.90 3.18 3.46 3.76 4.06 4.36 4.68 5.003.5 1.30 1.52 1.75 1.99 2.24 2.50 2.76 3.04 3.32 3.61 3.91 4.21 4.52 4.84 5.174.0 1.62 1.86 2.10 2.36 2.62 2.89 3.17 3.46 3.75 4.05 4.36 4.68 5.00 5.334.5 1.96 2.21 2.47 2.74 3.02 3.31 3.60 3.90 4.20 4.52 4.84 5.17 5.505.0 2.33 2.59 2.87 3.15 3.44 3.74 4.04 4.35 4.67 5.00 5.33 5.675.5 2.71 2.99 3.28 3.57 3.88 4.19 4.50 4.82 5.15 5.49 5.836.0 2.83 3.11 3.41 3.71 4.02 4.33 4.65 4.98 5.31 5.65 6.006.5 3.24 3.54 3.84 4.16 4.47 4.80 5.13 5.47 5.82 6.177.0 3.67 3.98 4.29 4.62 4.95 5.29 5.63 5.98 6.337.5 4.11 4.43 4.76 5.10 5.44 5.79 6.14 6.508.0 4.57 4.91 5.25 5.59 5.95 6.30 6.678.5 5.05 5.40 5.75 6.10 6.47 6.839.0 5.20 5.55 5.90 6.26 6.63 7.009.5 5.69 6.05 6.42 6.79 7.17

10.0 6.21 6.58 6.95 7.3310.5 6.74 7.12 7.5011.0 7.28 7.6711.5 7.8312.0 8.00

1V,f

ßsin5,0ßcos

1V,f

2V,f

for 0° ß 55°

for 55° < ß 90°

for 90° < ß 180°

Formulae:

V ... applied shear force

These results are for a two-anchor fastening. For fastenings with more than two anchors, use the general formulae for n anchors at the top of the page.

results tabulatedbelow

Page 99: Ancore Chimice Mecanice Pentru Sarcinimari

HVU adhesive with HIS-N/HIS-RN sleeve

Issue 2005 217

3

VRd,s : Steel design shear resistance

Anchor size M8 M10 M12 M16 M20

VRd,s1) [kN] Bolt steel grade 5.8 8.8 13.9 20.2 37.7 58.8

steel grade 8.8 14.1 22.3 32.4 60.3 94.1 A4-70 9.9 15.6 22.7 42.3 66.0 1) The design shear resistance is calculated from VRd,s= (0,6 As fuk)/ Ms,V. The values for the stressed cross-section, As , of the bolt and the nominal tensile steel strength, fuk , are taken from the bolt standard ISO 898. The partial safety factor, Ms,V , for grades 5.8 and 8.8 is 1.25 and 1.56 for grade A4-70.

VRd : System design shear resistance

VRd = lower of VRd,c and VRd,sbolt

Combined loading: Only if tensile load and shear load applied (See page 31 and section 4 “Examples”).

Page 100: Ancore Chimice Mecanice Pentru Sarcinimari

HVZ adhesive anchor

180 Issue 2005

Features:

- foil capsule vs. glass

- flexibly to fit in irregular holes

- marking for identification after setting

- test reports: fire, dynamic (fatigue, shock), water tightness

Material:

HVU-(E-)TZ:

- urethane methacrylate resin – styrene free,

hardener,

quartz sand, foil tubes

HAS-(E-)TZ: - grade 8.8; EN ISO 20898-1; coating: DIN 50968-

FE/Cu 3 Ni 10

HAS-(E-)RTZ: - stainless steel; A4-80; 1.4401; 14571; EN 10088

HAS-(E-)HCR-TZ: - stainless steel; 1.4529; 1.4547; EN 10088-3

HVU-TZ capsule

HAS-TZ, HAS-RTZ and

HAS-HCR-TZ anchor rod

Concrete Tensile zone Close edge distance/ spacing

Fatigue Shock

A4316

HCRhighMo

Corrosion resistance

High corrosion resistance

Fire resistance Hilti Anchor programme

Basic loading data (for a single anchor): HAS-(E-)TZ

All data on this page applies to For detailed design method, see pages 184 – 189. concrete: See table below. correct setting (See setting operations page 183) no edge distance and spacing influence

steel failure

Mean ultimate resistance Ru,m [kN]: concrete C20/25

Anchor size M10 M12 M16 M16L M20 M10 M12 M16 M16L M20

Tensile NRu,m 38.2 49.0 82.1 82.1 132.9 38.2 49.0 68.7 72.0 132.9

Shear VRu,m 20.1 29.2 54.2 54.2 93.3 20.1 29.2 54.2 54.2 93.3

Characteristic resistance, Rk [kN]: concrete C20/25

Anchor size M10 M12 M16 M16L M20 M10 M12 M16 M16L M20

Tensile NRk 32.7 40.0 54.3 70.5 111.8 20.0 33.3 38.7 50.3 79.8 Shear VRk 18.0 27.0 51.0 51.0 88.0 18.0 27.0 51.0 51.0 88.0

Following values according to the:

Concrete Capacity Method

Design resistance, Rd [kN]: concrete fck,cube = 25 N/mm2

Anchor size M10 M12 M16 M16L M20 M10 M12 M16 M16L M20

Tensile NRd 21.8 26.7 36.2 47.0 74.5 13.3 22.2 25. 8 33.5 53.2 Shear VRd 14.4 21.6 40.8 40.8 70.4 14.4 21.6 40.8 40.8 70.4

Recommended load, Lrec [kN]: concrete fck,cube = 25 N/mm2

Anchor size M10 M12 M16 M16L M20 M10 M12 M16 M16L M20

Tensile NRec 15.6 19.1 25.8 33.6 53.2 9.5 15.9 18.4 23.9 38.0 Shear VRec 10.3 15.4 29.1 29.1 50.3 10.3 15.4 29.1 29.1 50.3

non-cracked concrete cracked concrete

Page 101: Ancore Chimice Mecanice Pentru Sarcinimari

HVZ adhesive anchor

Issue 2005 181

Basic loading data (for a single anchor): HAS-(E-)RTZ

All data on this section applies to For detailed design method, see pages 184 – 189. concrete: See table below. correct setting (See setting operations page 183) no edge distance and spacing influence

steel failure

Mean ultimate resistance, Ru,m [kN]: concrete C20/25

Anchor size M10 M12 M16 M16L M20 M10 M12 M16 M16L M20

Tensile NRu,m 38.2 49.0 82.1 82.1 132.9 38.2 49.0 68.7 72.0 132.9

Shear VRu,m 22.6 32.7 61.0 61.0 103.9 22.6 32.7 61.0 61.0 103.8

Characteristic resistance, Rk [kN]: concrete C20/25

Anchor size M10 M12 M16 M16L M20 M10 M12 M16 M16L M20

Tensile NRk 32.7 40.0 54.3 70.5 111.8 20.0 33.3 38.7 50.3 79.8 Shear VRk 20.0 30.0 56.0 56.0 98.0 20.0 30.0 56.0 56.0 98.0

Following values according to the:

Concrete Capacity Method

Design resistance, Rd [kN]: concrete fck,cube = 25 N/mm2

Anchor size M10 M12 M16 M16L M20 M10 M12 M16 M16L M20

Tensile NRd 21.8 26.7 36.2 47.0 74.5 13.3 22.2 25..8 33.5 53.2 Shear VRd 16.0 24.0 44.8 44.8 78.4 16.0 24.0 44.8 44.8 78.4

Recommended load, Lrec [kN]: concrete fck,cube = 25 N/mm2

Anchor size M10 M12 M16 M16L M20 M10 M12 M16 M16L M20

Tensile NRec 15.6 19.1 25.8 33.6 53.2 9.5 15.9 18.4 23.9 38.0 Shear VRec 11.4 17.1 32.0 32.0 56.0 11.4 17.1 32.0 32.0 56.0

Basic loading data (for a single anchor): HAS-(E-)HCR-TZ

All data on this section applies to For detailed design method, see pages 184 – 189. concrete: See table below. correct setting (See setting operations page 183) no edge distance and edge influence

steel failure

Mean ultimate resistance, Ru,m [kN]: concrete C20/25

Anchor size M10 M12 M16 M16L M20 M10 M12 M16 M16L M20

Tensile NRu,m 38.2 49.0 82.1 82.1 132.9 38.2 49.0 68.7 72.0 132.9

Shear VRu,m 25.1 36.4 61.0 61.0 105.8 25.1 36.4 61.0 61.0 105.8

non-cracked concrete cracked concrete

non-cracked concrete cracked concrete

3

Page 102: Ancore Chimice Mecanice Pentru Sarcinimari

HVZ adhesive anchor

182 Issue 2005

Characteristic resistance Rk [kN]: concrete C20/25

Anchor size M10 M12 M16 M16L M20 M10 M12 M16 M16L M20

Tensile NRk 32.7 40.0 54.3 70.5 111.8 20.0 33.3 38.7 50.3 79.8 Shear VRk 20.0 30.0 56.0 56.0 98.0 20.0 30.0 56.0 56.0 98.0

Following values according to the:

Concrete Capacity Method

Design resistance Rd [kN]: concrete fck,cube = 25 N/mm2

Anchor size M10 M12 M16 M16L M20 M10 M12 M16 M16L M20

Tensile NRd 21.8 26.7 36.2 47.0 74.5 13.3 22.2 25..8 33.5 53.2 Shear VRd 16.0 24.0 44.8 44.8 78.4 16.0 24.0 44.8 44.8 78.4

Recommended load, Lrec [kN]: concrete fck,cube = 25 N/mm2

Anchor size M10 M12 M16 M16L M20 M10 M12 M16 M16L M20

Tensile NRec 15.6 19.1 25.8 33.6 53.2 9.5 15.9 18.4 23.9 38.0 Shear VRec 11.4 17.1 32.0 32.0 56.0 11.4 17.1 32.0 32.0 56.0

Setting details

Anchor size M10x75 M12x95 M16x105 M16x125 M20x170

Foil capsule HVU-TZ M.. 10x90 12x110 16x125 20x190

Anchor rod HAS-(E-)TZ M.. 10x75/ tfix 12x95/ tfix 16x105/ tfix 16Lx125/tfix 20x170/ 40

d0 [mm] Drill bit diameter 12 14 18 25

h1 [mm] Hole depth 90 110 125 145 195

hmin [mm] Min. thickness of base material 150 190 210 250 340

tfix [mm] Max. fixture thickness 15 / 30 / 50 25 / 50 / 100 (and 40 for HAS-RTZ)

30 / 60 / 100 40

df [mm] Clearance hole rec.

(without bending verification) max. 1213

1415

1819

22

Tinst [Nm]Tightening HAS-TZTorque HAS-R/HCR-TZ

4050

5070

90100 150

Drill bit TE–CX 12/22 TE-TX 12/32

TE–CX 14/22 TE-TX 14/32

TE–C 18/32S TE-T 18/32

TE–C 25/27STE-T 25/32

d0

df

t fixhef

h1

hmin

HV

Z ...

HAS-E-TZHAS-TZ

Page 103: Ancore Chimice Mecanice Pentru Sarcinimari

HVZ adhesive anchor

Issue 2005 183

3

Base material temperature Min. time to wait before removing SCREWED-ON

setting tool (not applicable for TE-C HEX):

trel

Curing time: tcure

20°C and higher10°C to 20°C0°C to 10°C-5°C to 0°C

8 min. 20 min. 30 min. 1 hour

20 min. 30 min. 1 hour 5 hours

less than -5°C Please consult your Hilti technical service.

Installation equipment

A rotary hammer (TE5, TE6, TE15, TE-15C, TE-18M, TE35, TE55, TE76); max. setting speed of 850 r.p.m (rotary hammering action); a drill bit, a blow out pump and a setting tool: TE-C HEX (M10-M16), TE-Y HEX(M20);

Setting operations

1 2 3

®®®

HVU-TZ 4TE-C HEX

Drill hole. Blow out dust and

fragments.Insert HVU-TZ capsule.

Drive in with rotary hammering action.

trel5

tcure

6 7 Tinst

Allow rel time to pass Wait for curing Apply tightening torque.

Anchor geometry and mechanical properties

dp

lp

HVU-TZ M.. HVU-TZ M..

Marking of material and anchorage depthfor HAS-TZ: HVZ...for HAS-RTZ: HVZ R...for HAS-HCR: HVZ HCR...

d

dk

hefl

Sw

dw

Page 104: Ancore Chimice Mecanice Pentru Sarcinimari

HVZ adhesive anchor

184 Issue 2005

Anchor size M10 M12 M16x105 M16x125 M20

HVU-TZ capsule:

lp [mm] HVU-TZ foil capsule length 110 127 140 200 dp [mm] HVU-TZ foil capsule diameter 11.0 13.0 17.0 23.0

HAS-(E-)TZ/-RTZ/-HCR-TZ:

Stressed cross-sectional area under tensile loading:

44.2 56.7 95.0 153.9

As [mm²] Stressed cross-sectional area under shear loading in thread:

58.0 84.3 157.0 245.0

fuk [N/mm²]Nominal tensile strength (point)

HAS-TZ 8.8 HAS-RTZ

HAS-HCR-TZ

800800800

fyk [N/mm²]Nominal yield strength (point)

HAS-TZ 8.8 HAS-RTZ

HAS-HCR-TZ

640600600

W [mm³] Section modulus 62.3 109.0 277.0 541

MRd,s [Nm] Design bending resistance

HAS-TZ 8.8 HAS-RTZ and HAS-HCR-TZ

38.4 68.8 181.6 415.2

d [mm] Shank diameter 10 12 16 20 dk [mm] Anchor end diameter 10.8 12.8 16.8 22.7 hef [mm] Actual anchorage depth 75 95 105 125 170 l [mm] Anchor length 124/139/159 158/183/233 181/211/251 201/231/271 269 Sw [mm] Width across flats 17 19 24 30 dw [mm] Washer outside diameter 20 24 30 37 1) The design bending resistance of the anchor rod was calculated using MRd,s = MRk,s/ Ms,b , where the partial safety factor Ms,b is 1.25.

Detailed design method - Hilti CC

Caution: In view of the high loads transferable with HVZ, it must be verified by the user that the load on the concrete structure including the loads introduced by the anchorage do not cause failure (e.g. cracking) of the concrete structure.

TENSION

The tensile design resistance of a single anchoris the lower of,

NRd,c : concrete cone/pull-out resistance

NRd,s : steel resistance

(The Hilti CC-Method is a simplified Version of ETAG Annex C)

N

cs

h

rec,c/s

Page 105: Ancore Chimice Mecanice Pentru Sarcinimari

HVZ adhesive anchor

Issue 2005 185

3

NRd,c: Concrete cone/pull-out resistance

N,RN,AN,Bo

c,Rdc,Rd fffNN

N0Rd,c : Concrete cone/pull-out design resistance

Concrete compressive strength fck,cube(150) = 25 N/mm2

Anchor size M10 M12 M16 M16L M20

N0

Rd,c1)

[kN] in non-cracked concrete 21.8 26.7 36.2 47.0 74.5

N0

Rd,c1)

[kN] in cracked concrete 13.3 22.2 25.8 33.5 53.2

hef [mm] Actual anchorage depth 75 95 105 125 170 1) The design tensile resistance is calculated from the characteristic tensile resistance No

Rk,c by NoRd,c= No

Rk,c/ Mc,N, where the partial safety factor Mc,N is 1.5.

fB,N : Influence of concrete strength

Concrete strength designation(ENV 206)

Cylinder compressive strength

fck,cyl [N/mm²]

Cube compressive strength

fck,cube [N/mm²] fB,N

C20/25 20 25 1

C25/30 25 30 1.1

C30/37 30 37 1.22

C35/45 35 45 1.34

C40/50 40 50 1.41

C45/55 45 55 1.48

C50/60 50 60 1.55

Concrete cylinder:

height 30cm, 15cm

diameter

Concrete cube:

side length 15cm

Concrete test specimen geometry

fA,N: Influence of spacing

Spacing, Anchor size

s [mm] M10 M12 M16 M16L M20

50 0.61 60 0.63 0.60 65 0.64 0.61 70 0.66 0.62 0.61 0.59 75 0.67 0.63 0.62 0.60 80 0.68 0.64 0.63 0.61 0.58 85 0.69 0.65 0.63 0.61 0.58 90 0.70 0.66 0.64 0.62 0.59

100 0.72 0.68 0.66 0.63 0.60 120 0.77 0.71 0.69 0.66 0.62 135 0.80 0.74 0.71 0.68 0.63 140 0.81 0.75 0.72 0.69 0.64 160 0.86 0.78 0.75 0.71 0.66 180 0.90 0.82 0.79 0.74 0.68 200 0.94 0.85 0.82 0.77 0.70 220 1.00 0.89 0.85 0.79 0.72 240 0.92 0.88 0.82 0.74

25

ff

cubeck,

NB,

Limits: 25 N/mm2 fck,cube 60 N/mm2

Page 106: Ancore Chimice Mecanice Pentru Sarcinimari

HVZ adhesive anchor

186 Issue 2005

fA,N: Influence of spacing

Spacing, Anchor size

s [mm] M10 M12 M16 M16L M20

270 0.97 0.93 0.86 0.76 300 1.00 0.98 0.90 0.79 330 1.00 0.94 0.82 360 0.98 0.85 390 1.00 0.88 420 0.91 450 0.94 480 0.97 510 1.00

fR,N: Influence of edge distance

Edge Anchor size

distance,

c [mm] M10 M12 M16 M16L M20

50 0.58

60 0.65

65 0.68

70 0.72 0.62

75 0.75 0.64

80 0.78 0.67 0.49

85 0.82 0.70 0.65 0.59 0.50

90 0.85 0.72 0.68 0.61 0.51

95 0.88 0.75 0.70 0.63 0.53

100 0.92 0.78 0.73 0.65 0.54

105 0.95 0.80 0.75 0.67 0.56

110 0.98 0.83 0.77 0.69 0.57

115 1.00 0.86 0.80 0.71 0.59

125 0.91 0.85 0.75 0.62

135 0.96 0.89 0.79 0.65

145 1.00 0.94 0.83 0.68

155 1.00 0.87 0.71

165 0.91 0.74

175 0.95 0.76

185 1.00 0.79

205 0.85

230 0.93

255 1.00

efN,R

h

c50.025.0f Limits: cmin c ccr,N

Anchor size M10 M12 M16 M16L M20cmin [mm] 50 70 85 80 ccr,N [mm] 113 143 158 188 255

Note: If more than 3 edge distances are smaller than ccr,N, please contact your Hilti technical service.

efN,A

h6

s5.0f Limits: smin s scr,N

Anchor size M10 M12 M16 M16L M20smin [mm] 50 60 70 80 scr,N [mm] 225 285 315 375 510

Page 107: Ancore Chimice Mecanice Pentru Sarcinimari

HVZ adhesive anchor

Issue 2005 187

3

NRd,s : Steel design tensile resistance

Anchor size M10 M12 M16 M16L M20

NRd,s1) [kN] 23.3 34.0 60.0 121.3

1) The design value is calculated using NRd,s= NRk,s / Ms,N, where the partial safety factor, Ms,N , is 1.5.

NRd : System design tensile resistance

NRd = lower of NRd,c and NRd,s

Combined loading: Only if tensile load and shear load applied (See page 31 and section 4 “Examples”).

Detailed design method – Hilti CC

SHEAR

The design shear resistance of a single anchor is the lower of,

VRd,c : concrete edge resistance

VRd,s : steel resistance Note: If the conditions shown for h and c2 cannot be observed, please contact your Hilti sales representative.

VRd,c : Concrete edge design resistance

The lowest concrete edge resistance must be calculated. All near edges must be checked, (not only the edge in the direction of shear). The direction of shear is accounted by the factor f ,V.

V,ARV,V,B0

c,Rdc,Rd fffVV

V0Rd,c : Concrete edge design resistance

Concrete compressive strength fck,cube(150) = 25 N/mm2

at a minimum edge distance minc

V

cs

rec,c/sc >1.5c2

c >1.5c2

h>1.5c

(The Hilti CC-Method is a simplified Version of ETAG Annex C)

Page 108: Ancore Chimice Mecanice Pentru Sarcinimari

HVZ adhesive anchor

188 Issue 2005

Anchor size M10 M12 M16 M16L M20

V0

Rd,c1) [kN] non-cracked concrete 3.5 6.4 9.6 9.9 10.3

V0

Rd,c1) [kN] cracked concrete 2.5 4.6 6.9 7.1 7.4

cmin [mm] min. edge distance 50 70 85 80 1) The design value of the ultimate state in shear is calculated from the characteristic anchor shear resistance, V°Rk,c, divided by V°Rd,c= V°Rk,c/ Mc,V, where the partial safety factor, Mc,V, is 1.5.

fB,V : Influence of concrete strength

Concrete strength designation(ENV 206)

Cylinder compressive strength

fck,cyl [N/mm²]

Cube compressive strength

fck,cube [N/mm²] fB,V

C20/25 20 25 1

C25/30 25 30 1.1

C30/37 30 37 1.22

C35/45 35 45 1.34

C40/50 40 50 1.41

C45/55 45 55 1.48

C50/60 50 60 1.55

Concrete cylinder:

height 30cm, 15cm

diameter

Concrete cube:

side length 15cm

Concrete test specimen geometry

f ,V : Influence of shear load direction

Angle [°] f ,V

0 to 55 1

60 1.1

70 1.2

80 1.5

90 to 180 2

Formulae:

1f V,

sin5.0cos

1f V,

2f V,

for 0° 55°

for 55° < 90°

for 90° < 180°

fAR,V : Influence of edge distance and spacing

Formula for single-anchor fasteningInfluenced only by edge

minminV,AR

c

c

c

cf

Formula for a two-anchor fastening valid for s < 3c

minminV,AR c

c

c6

sc3f

General formula for n-anchor fastening (edge plus n-1 spacing) only valid where s1 to sn-1 are all < 3c and c2 > 1.5c

minmin

1n21V,AR c

c

nc3

s...ssc3f

25

ff

cubeck,

VB,

Limits: 25 N/mm2 fck,cube 60 N/mm2

resultstabulatedbelow

V ... applied shear force

ccs

ss

2,2

1

2

3

n-1sc2,1

h >1,5 c

Note: It is assumed that only the row of anchors closest to the free concrete edge carries the centric shear load

Page 109: Ancore Chimice Mecanice Pentru Sarcinimari

HVZ adhesive anchor

Issue 2005 189

3

fAR.V c/cmin

1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 3.2 3.4 3.6 3.8 4.0

Single anchor with edge influence 1.00 1.31 1.66 2.02 2.41 2.83 3.26 3.72 4.19 4.69 5.20 5.72 6.27 6.83 7.41 8.00

s/cmin 1.0 0.67 0.84 1.03 1.22 1.43 1.65 1.88 2.12 2.36 2.62 2.89 3.16 3.44 3.73 4.03 4.331.5 0.75 0.93 1.12 1.33 1.54 1.77 2.00 2.25 2.50 2.76 3.03 3.31 3.60 3.89 4.19 4.502.0 0.83 1.02 1.22 1.43 1.65 1.89 2.13 2.38 2.63 2.90 3.18 3.46 3.75 4.05 4.35 4.672.5 0.92 1.11 1.32 1.54 1.77 2.00 2.25 2.50 2.77 3.04 3.32 3.61 3.90 4.21 4.52 4.833.0 1.00 1.20 1.42 1.64 1.88 2.12 2.37 2.63 2.90 3.18 3.46 3.76 4.06 4.36 4.68 5.003.5 1.30 1.52 1.75 1.99 2.24 2.50 2.76 3.04 3.32 3.61 3.91 4.21 4.52 4.84 5.174.0 1.62 1.86 2.10 2.36 2.62 2.89 3.17 3.46 3.75 4.05 4.36 4.68 5.00 5.334.5 1.96 2.21 2.47 2.74 3.02 3.31 3.60 3.90 4.20 4.52 4.84 5.17 5.505.0 2.33 2.59 2.87 3.15 3.44 3.74 4.04 4.35 4.67 5.00 5.33 5.675.5 2.71 2.99 3.28 3.57 3.88 4.19 4.50 4.82 5.15 5.49 5.836.0 2.83 3.11 3.41 3.71 4.02 4.33 4.65 4.98 5.31 5.65 6.006.5 3.24 3.54 3.84 4.16 4.47 4.80 5.13 5.47 5.82 6.177.0 3.67 3.98 4.29 4.62 4.95 5.29 5.63 5.98 6.337.5 4.11 4.43 4.76 5.10 5.44 5.79 6.14 6.508.0 4.57 4.91 5.25 5.59 5.95 6.30 6.678.5 5.05 5.40 5.75 6.10 6.47 6.839.0 5.20 5.55 5.90 6.26 6.63 7.009.5 5.69 6.05 6.42 6.79 7.17

10.0 6.21 6.58 6.95 7.3310.5 6.74 7.12 7.5011.0 7.28 7.6711.5 7.8312.0 8.00

VRd,s : Steel design shear resistance

Anchor size M10 M12 M16 M16L M20

VRd,s1)[kN] HAS-(E-)TZ 14.4 21.6 40.8 70.4

VRd,s1) [kN HAS-(E-)RTZ, HAS-(E-)HCR 16.0 24.0 44.8 78.4

1) The design shear resistance is calculated using VRd,s= VRk,s/ Ms,V. The values for the stressedcross section As and the nominal tensile strength of steel, fuk, are given in the table „Anchor mechanical properties and geometry“. The partial safety factor, Ms,V is 1.25.

VRd : System design shear resistance

VRd : System shear design resistance

VRd = lower of VRd,c and VRd,s

Combined loading: Only if tensile load and shear load applied (See page 31 and section 4 “Examples”).

These results are for a two-. Anchor fastening.

For fastening made with more than 2 anchors, use the general formulae for n anchors.


Recommended